Outback Power Systems OBX-IC2024S-120/60 Inverter Default Values subject to change with upgrades

Page 38

INVERTER DEFAULT VALUES (subject to change with upgrades)

24 VDC System

DEFAULT

MINIMUM

MAXIMUM

Float Voltage

27.4 Vdc

24 Vdc

30 Vdc

Absorb Voltage

29.4 Vdc

26 Vdc

32 Vdc

EQ Voltage

28.8 V

28 Vdc

34 Vdc

ReFloat

25 Vdc

22 Vdc

26 Vdc

LBCO

21 Vdc

18 Vdc

24 Vdc

Absorb Time

2.0 hours

0.0 hours

24.0 hours

EQ Time

1.0 hours

0.0 hours

24.0 hours

Float Time

1.0 hours

0.0 hours

24.0 hours

Charger Draw

5 Aac

0 Aac

7 Aac

AC1/Grid Transfer Delay

6 AC cycles

0 AC cycles

240 AC cycles

AC2/Gen Transfer Delay

60 AC cycles

0 AC cycles

240 AC cycles

 

 

 

 

Grid Lower Limit

108 Vac

40 Vac

115 Vac

Grid Upper Limit

140 Vac

130 Vac

150 Vac

Grid Connect Delay

0.5 min

0.2 min

15.0 min

Gen Lower Limit

108 Vac

40 Vac

115 Vac

Gen Upper Limit

140 Vac

130 Vac

150 Vac

 

 

 

 

AC DROP or USE

USE

N/A

N/A

Charger OFF/AUTO/ON

AUTO

N/A

N/A

 

 

 

 

Search Threshold

6 watts

0 watts

50 watts

Search Pulses

8

2

20

Search Pulse Spacing

60 AC cycles

4 AC cycles

120 AC cycles

Stacking Phase

1 or 2 phase

N/A

N/A

InPut Select

Gen

N/A

N/A

Grid Input Settings

28 Aac

5 Aac

30 Aac

Gen Input Settings

28 Aac

2 Aac

30 Aac

Set Output Voltage

120 Vac

115 Vac

125 Vac

36

Image 38
Contents OBX-IC2024S-120/60 Contact Information OutBack Power SystemsWarranty Summary DisclaimerTable of Contents OutBack Extreme Rugged Water Resistant Inverter/Charger Parts Included Unit DimensionsInverter Maintenance Required ConductorsInitial Inspection Use and StorageImportant Battery Instructions Safety and Human FactorsMounting System Protection AC and DC Grounding RequirementsConnection Torque Wire ConnectionsDC Wiring Battery Wiring SERIES/PARALLEL ExampleBattery Wiring Examples for a 24-volt system Battery Wiring Examples for a 24-volt system AC Wiring Connector PlatePage Powering UP Locking collarMounting the Mate MATE2 System Controller and DisplayMate AT a Glance 13504pHOT Keys INV Hot KeyAC in Hot Key KeyPress Three Times Summary Screens SUM Status Setup ADVSoft Keys Srch Input Main Setup ScreensFxmate Down Grid GEN PortBack Type Delay Roll PG1 Sumry COM Main SETUP/MATE/SUMMARYBack Type Delay Roll SETUP/MATE/SUMMARY Clock CNT Glow PG2Back INC DEC SETUP/MATE/SUMMARY SETUP/MATE/SUM/TYPEBack INC DEC SETUP/MATE/SUM/TYPE Back INC DECBack INC DEC SETUP/MATE/SUMMARY/TYPE Communication Setup ScreensSETUP/MATE/SUMMARY/TYPE PG1 Sumry COM MainPG1 Sumry Comm Main Back Repoll PC DebugStatus Screens FX CC DC MainReading a Status Screen Status Meter Screens DefinitionStatus Battery Screens Pressing the Batt soft key brings up the first Batt screenStatus Error Screens Modes Meter Batt PG2 PG1 Error Warn PG3Status Warning Screens Status Disconnect Screens Disconnect ScreensInstallation Drawing Installation Check List OBX-IC2024S-120/60 Inverter/Charger Specifications Maximum AC Input Current Model Ampacity DC Breaker DC FuseInverter Default Values subject to change with upgrades VDC SystemMaintenance TroubleshootingYear Limited Warranty OutBack Extreme Inverter/Chargers2008-01-07 Address for warranty certificate Equipment OwnerPage Corporate Headquarters European Sales Office