WARN(ING) Screens

All warning screens read status as “No” under normal conditions. If the appropriate condition is met, that screen will change to “Yes.”

acin freq too high: AC source is above 66 Hz (upper limit) and will be dropped

acin freq too low: AC source is under 54 Hz (lower limit) and will be dropped

acin voltage too high: AC source’s voltage is over 140 Vac (default limit) and will be dropped

acin voltage too low: AC source’s voltage is under 108 Vac (default limit) and will be dropped

acin input current exceeds max: AC loads are drawing more current than the rating of the FX allows

temperature sensor fault: an internal FX temperature sensor is malfunctioning

internal comm error detected: there is a communication problem between MATE and Inverter (see p. 23)

internal fan failure detected: the Inverter’s internal cooling fan is not operating properly

The following items are not warnings, but are data readings related to the temp sensor warning

airtemp: displays a numeric value representing the air temperature around the Inverter

fettemp: displays a numeric value representing the temperature of the FETs (Field Effect Transistors)

captemp: displays a numeric value representing the temperature of the ripple capacitors

(These values are used for troubleshooting purposes. The higher the numerical value, the cooler the temperature.)

Status Discon(nect) Screens

STATUS/FX/PAGE2------------------

STATUS/FX/PAGE2-----------------

choose category:

choose category:

 

PG1 ERROR WARN PG3

PG2 DISCON

SELL MAIN

Pressing the <PG3> soft key brings up more STATUS categories.

Pressing the <DISCON> soft key brings up the first DISCON screen.

Pressing the <DOWN> soft key brings up successive DISCON screens.

STATUS/FX/DISCON-----------

P00

STATUS/FX/DISCON----------

P00

STATUS/FX/DISCON-----------

P00

acin freq

 

No

acin freq

 

 

No

acin voltage

 

No

too high

 

 

too low

 

 

 

> max

 

 

 

DOWN

STATUS

PORT

DOWN

UP

TOP

PORT

DOWN

UP

TOP

PORT

STATUS/FX/DISCON-----------

P00

STATUS/FX/DISCON----------------

STATUS/FX/PAGE2----------------

acin voltage

 

No

end of DISCON menu

choose category:

< min

 

 

 

 

 

DOWN

UP TOP

PORT

UP

TOP STATUS

PG2 DISCON SELL MAIN

Push <TOP> to return to the first ERROR screen.

Push <STATUS> to return to the “choose category” STATUS /FX/PAGE2 screen.

Push <MAIN> to return to the Main screen.

DISCON(NECT) Screens

acin freq too high: displays “Yes” if the AC source exceeds 66 Hz and the Inverter disconnects from the source

acin freq too low: displays “Yes” if the Inverter disconnects from an AC source below 54 Hz

acin voltage > max: the source of the AC voltage exceeds the Inverter maximum of 140 Vac

acin voltage < min: the source of the AC voltage falls below the Inverter minimum of 108 Vac

31

Image 33
Contents OBX-IC2024S-120/60 Warranty Summary OutBack Power SystemsContact Information DisclaimerTable of Contents OutBack Extreme Rugged Water Resistant Inverter/Charger Inverter Maintenance Unit DimensionsParts Included Required ConductorsUse and Storage Initial InspectionSafety and Human Factors Important Battery InstructionsMounting AC and DC Grounding Requirements System ProtectionWire Connections DC WiringConnection Torque SERIES/PARALLEL Example Battery WiringBattery Wiring Examples for a 24-volt system Battery Wiring Examples for a 24-volt system Connector Plate AC WiringPage Locking collar Powering UPMate AT a Glance MATE2 System Controller and DisplayMounting the Mate 13504pINV Hot Key HOT KeysKey AC in Hot KeyPress Three Times SUM Status Setup ADV Soft KeysSummary Screens Fxmate Setup ScreensSrch Input Main Down Grid GEN PortBack Type Delay Roll SETUP/MATE/SUMMARY PG1 Sumry COM Main SETUP/MATE/SUMMARYBack Type Delay Roll Clock CNT Glow PG2Back INC DEC SETUP/MATE/SUM/TYPE SETUP/MATE/SUM/TYPEBack INC DEC SETUP/MATE/SUMMARY Back INC DECSETUP/MATE/SUMMARY/TYPE Communication Setup ScreensBack INC DEC SETUP/MATE/SUMMARY/TYPE PG1 Sumry COM MainBack Repoll PC Debug PG1 Sumry Comm MainFX CC DC Main Status ScreensReading a Status Screen Definition Status Meter ScreensPressing the Batt soft key brings up the first Batt screen Status Battery ScreensModes Meter Batt PG2 PG1 Error Warn PG3 Status Error ScreensStatus Warning Screens Disconnect Screens Status Disconnect ScreensInstallation Drawing Installation Check List OBX-IC2024S-120/60 Inverter/Charger Specifications Model Ampacity DC Breaker DC Fuse Maximum AC Input CurrentVDC System Inverter Default Values subject to change with upgradesTroubleshooting MaintenanceOutBack Extreme Inverter/Chargers Year Limited Warranty2008-01-07 Equipment Owner Address for warranty certificatePage Corporate Headquarters European Sales Office