Outback Power Systems OBX-IC2024S-120/60 Setup/Mate/Sum/Type, Back INC DEC SETUP/MATE/SUM/TYPE

Page 24

SETUP/MATE/SUM/TYPE---------

summary None screen type

BACK INC DEC

SETUP/MATE/SUM/TYPE---------

summary

 

FX Only

screen type

 

BACK

INC

DEC

Press either the <INC> and <DEC> soft keys to change the SUMMARY screen to one of the following items:

None — disables the SUMMARY screen from automatically opening; the SUMMARY screen can still be accessed via the <SUM> soft key on the MAIN screen.

FX Only—the SUMMARY screen for the Inverter is enabled and will open after a delay time (see below).

Continuing to press either the <INC> or <DEC> soft keys will bring up other summary screen options.

NOTE: Other options in this menu are not normally used with the OBX-IC2024S-120/60 Inverter.

SETUP/MATE/SUM/TYPE---------

summary

 

FX Only

screen type

 

BACK

INC

DEC

SETUP/MATE/SUMMARY----------

summary control

BACK TYPE DELAY ROLL

SETUP/MATE/SUMMARY----------

summary control

BACK TYPE DELAY ROLL

SETUP/MATE/SUMMARY----------

summary control

BACK TYPE DELAY ROLL

Press the <BACK> soft key to return to the Summary Control screen.

The <DELAY> soft key sets the time delay for the SUMMARY screen to appear. (See below and the next page.)

The <ROLL> soft key is not normally used with the OBXIC2024S120/60 Inverter.

After selecting FX Only and exiting the SETUP/MATE/SUM/ TYPE screen, the SUMMARY screen will automatically appear whenever the MATE has been inactive for the <DELAY> set point (very much like a screensaver on a computer monitor).

If “None” was selected, the MATE continues to display the last active screen viewed; if you press the <SUM> soft key on the MAIN menu when “None” is chosen, the FX SUMMARY screen appears.

To change the delay time:

In the SETUP/MATE/SUMMARY screen, press the <DELAY> soft key; this will take you to sum screen delay time.

22

Image 24
Contents OBX-IC2024S-120/60 OutBack Power Systems Warranty SummaryContact Information DisclaimerTable of Contents OutBack Extreme Rugged Water Resistant Inverter/Charger Unit Dimensions Inverter MaintenanceParts Included Required ConductorsInitial Inspection Use and StorageImportant Battery Instructions Safety and Human FactorsMounting System Protection AC and DC Grounding RequirementsWire Connections DC WiringConnection Torque Battery Wiring SERIES/PARALLEL ExampleBattery Wiring Examples for a 24-volt system Battery Wiring Examples for a 24-volt system AC Wiring Connector PlatePage Powering UP Locking collarMATE2 System Controller and Display Mate AT a GlanceMounting the Mate 13504pHOT Keys INV Hot KeyAC in Hot Key KeyPress Three Times SUM Status Setup ADV Soft KeysSummary Screens Setup Screens FxmateSrch Input Main Down Grid GEN PortPG1 Sumry COM Main SETUP/MATE/SUMMARY Back Type Delay Roll SETUP/MATE/SUMMARYBack Type Delay Roll Clock CNT Glow PG2SETUP/MATE/SUM/TYPE Back INC DEC SETUP/MATE/SUM/TYPEBack INC DEC SETUP/MATE/SUMMARY Back INC DECCommunication Setup Screens SETUP/MATE/SUMMARY/TYPEBack INC DEC SETUP/MATE/SUMMARY/TYPE PG1 Sumry COM MainPG1 Sumry Comm Main Back Repoll PC DebugStatus Screens FX CC DC MainReading a Status Screen Status Meter Screens DefinitionStatus Battery Screens Pressing the Batt soft key brings up the first Batt screenStatus Error Screens Modes Meter Batt PG2 PG1 Error Warn PG3Status Warning Screens Status Disconnect Screens Disconnect ScreensInstallation Drawing Installation Check List OBX-IC2024S-120/60 Inverter/Charger Specifications Maximum AC Input Current Model Ampacity DC Breaker DC FuseInverter Default Values subject to change with upgrades VDC SystemMaintenance TroubleshootingYear Limited Warranty OutBack Extreme Inverter/Chargers2008-01-07 Address for warranty certificate Equipment OwnerPage Corporate Headquarters European Sales Office