Outback Power Systems OBX-IC2024S-120/60 owner manual Powering UP, Locking collar

Page 16

locking collar

AC OUT PLUG

AC IN PLUG

MATE PLUG

To connect cables to the Connector Plate sockets:

Position each cable plug over the appropriate jack. The cables are easy to tell apart, as the AC In plug has six pins, the AC Out plug only has five, and the MATE plug is smaller than the others.

Match each cable to its matching jack and fit the plugs into the jacks. If necessary, twist the plugs back and forth until they fit, and then push them in until they seat in place. (The plugs are keyed to fit only one way into the jacks, so they cannot be plugged in the wrong way.)

Once each plug is seated, turn the locking collar clockwise a quarter-turn until you feel the plug lock into place.

POWERING UP

Once all connections are established, it is safe to turn the power on, in the following order:

Connect DC power, by closing the DC breaker or connecting the fuse. The MATE will power up. The Inverter will energize and begin delivering 120 volts to the output immediately. (The on/off function is controlled by the MATE. See the next section.)

Connect the load panel by turning on the main AC breaker. Measure voltage at the disconnect to ensure that the Inverter is operating. Once this is confirmed, you should be able to run loads immediately.

If an AC source is present, connect it by turning on the main AC input breaker. After a short delay, the Inverter will begin charging the battery.

14

Image 16
Contents OBX-IC2024S-120/60 OutBack Power Systems Warranty SummaryContact Information DisclaimerTable of Contents OutBack Extreme Rugged Water Resistant Inverter/Charger Unit Dimensions Inverter MaintenanceParts Included Required ConductorsInitial Inspection Use and StorageImportant Battery Instructions Safety and Human FactorsMounting System Protection AC and DC Grounding RequirementsDC Wiring Wire ConnectionsConnection Torque Battery Wiring SERIES/PARALLEL ExampleBattery Wiring Examples for a 24-volt system Battery Wiring Examples for a 24-volt system AC Wiring Connector PlatePage Powering UP Locking collarMATE2 System Controller and Display Mate AT a GlanceMounting the Mate 13504pHOT Keys INV Hot KeyAC in Hot Key KeyPress Three Times Soft Keys SUM Status Setup ADVSummary Screens Setup Screens FxmateSrch Input Main Down Grid GEN PortPG1 Sumry COM Main SETUP/MATE/SUMMARY Back Type Delay Roll SETUP/MATE/SUMMARYBack Type Delay Roll Clock CNT Glow PG2SETUP/MATE/SUM/TYPE Back INC DEC SETUP/MATE/SUM/TYPEBack INC DEC SETUP/MATE/SUMMARY Back INC DECCommunication Setup Screens SETUP/MATE/SUMMARY/TYPEBack INC DEC SETUP/MATE/SUMMARY/TYPE PG1 Sumry COM MainPG1 Sumry Comm Main Back Repoll PC DebugStatus Screens FX CC DC MainReading a Status Screen Status Meter Screens DefinitionStatus Battery Screens Pressing the Batt soft key brings up the first Batt screenStatus Error Screens Modes Meter Batt PG2 PG1 Error Warn PG3Status Warning Screens Status Disconnect Screens Disconnect ScreensInstallation Drawing Installation Check List OBX-IC2024S-120/60 Inverter/Charger Specifications Maximum AC Input Current Model Ampacity DC Breaker DC FuseInverter Default Values subject to change with upgrades VDC SystemMaintenance TroubleshootingYear Limited Warranty OutBack Extreme Inverter/Chargers2008-01-07 Address for warranty certificate Equipment OwnerPage Corporate Headquarters European Sales Office