AC Input Operating Voltage Range

Note: This is the recommended AC input voltage range to be supplied to the Inverter. Voltages outside of this range will not be accepted by the Inverter.

OBX-IC2024S-120/60 Inverter

80 – 150 Vac (Vac = volts AC)

AC Input Frequency Range

Note: If the AC input source is out of the range noted below, the Inverter will not connect or stay connected.

OBX-IC2024S-120/60 Inverter

54-66 Hz

Maximum AC Input Current

An AC input source connected to the Inverter supplies power for two separate internal AC circuits – the AC transfer switch and the battery charging system. The AC transfer switch transfers the AC input power to the AC loads. The Inverter’s battery charger will “back off” if the total AC loads—including the charger—exceed the AC input current limit (default setting is 30 Aac). This “Input Limit” can be adjusted using the MATE to avoid overloading a generator or trip a circuit breaker. If your generator cannot produce 30 Aac or you are connecting to an AC input source that has a breaker that is rated for less than 30 Aac, please refer to page 20 to change this setting.

OBX-IC2024S-120/60 Inverter

30 Aac (Aac = Amps AC)

Maximum Current For Battery Charger (bulk stage)

OBX-IC2024S-120/60 Inverter

AC Max = 14 Aac (Default = 12 Aac)

DC Max = 55 Adc

Maximum AC Output Current

This is the amount of surge current that the Inverter will quickly supply for a split second. Depending on the size of the surge, the Inverter can be overloaded for a minimum time of 5 seconds to a maximum time of 30 minutes.

OBX-IC2024S-120/60 Inverter

70 Aac for 1 millisecond

Maximum Overcurrent Protection Ampacity

This rating specifies the proper overcurrent protection ampacity.

Bolt-in type class T DC fuses and should always be used in conjuncture with a disconnect mechanism.

Inverters used in fixed installations should use properly sized DC circuit breakers.

A DC breaker includes both overcurrent protection and disconnect capability.

OutBack Power Systems recommends Class T fuses for mobile installations where a DC disconnect is not required.

Model

Ampacity

DC Breaker

DC Fuse

OBX-IC2024S-120/60 Inverter

175 Adc

OBB-175-125VCD-PNL

Class T-300

35

Image 37
Contents OBX-IC2024S-120/60 Warranty Summary OutBack Power SystemsContact Information DisclaimerTable of Contents OutBack Extreme Rugged Water Resistant Inverter/Charger Inverter Maintenance Unit DimensionsParts Included Required ConductorsUse and Storage Initial InspectionSafety and Human Factors Important Battery InstructionsMounting AC and DC Grounding Requirements System ProtectionDC Wiring Wire ConnectionsConnection Torque SERIES/PARALLEL Example Battery WiringBattery Wiring Examples for a 24-volt system Battery Wiring Examples for a 24-volt system Connector Plate AC WiringPage Locking collar Powering UPMate AT a Glance MATE2 System Controller and DisplayMounting the Mate 13504pINV Hot Key HOT KeysKey AC in Hot KeyPress Three Times Soft Keys SUM Status Setup ADVSummary Screens Fxmate Setup ScreensSrch Input Main Down Grid GEN PortBack Type Delay Roll SETUP/MATE/SUMMARY PG1 Sumry COM Main SETUP/MATE/SUMMARYBack Type Delay Roll Clock CNT Glow PG2Back INC DEC SETUP/MATE/SUM/TYPE SETUP/MATE/SUM/TYPEBack INC DEC SETUP/MATE/SUMMARY Back INC DECSETUP/MATE/SUMMARY/TYPE Communication Setup ScreensBack INC DEC SETUP/MATE/SUMMARY/TYPE PG1 Sumry COM MainBack Repoll PC Debug PG1 Sumry Comm MainFX CC DC Main Status ScreensReading a Status Screen Definition Status Meter ScreensPressing the Batt soft key brings up the first Batt screen Status Battery ScreensModes Meter Batt PG2 PG1 Error Warn PG3 Status Error ScreensStatus Warning Screens Disconnect Screens Status Disconnect ScreensInstallation Drawing Installation Check List OBX-IC2024S-120/60 Inverter/Charger Specifications Model Ampacity DC Breaker DC Fuse Maximum AC Input CurrentVDC System Inverter Default Values subject to change with upgradesTroubleshooting MaintenanceOutBack Extreme Inverter/Chargers Year Limited Warranty2008-01-07 Equipment Owner Address for warranty certificatePage Corporate Headquarters European Sales Office