Outback Power Systems OBX-IC2024S-120/60 owner manual Status Battery Screens

Page 30

Status Batt(ery) Screens

STATUS/FX/PAGE 1----------------

Pressing the <BATT> soft key brings up the first BATT screen.

 

choose category:

Pressing the <DOWN> soft key brings up successive BATT screens.

 

MODES METER BATT PG2

 

STATUS/FX/MODE-------------

P00

STATUS/FX/MODE

-------------

P00

STATUS/FX/METER-------------

P00

battery

27.8 vdc

battery

 

 

27.8 vdc

absorb

 

 

28.8 vdc

actual

 

 

temp compensated

 

setpoint

 

 

 

DOWN

STATUS

PORT

DOWN

UP

TOP

PORT

DOWN

UP

TOP

PORT

STATUS/FX/BATT---------------

P00

STATUS/FX/BATT---------------

P00

STATUS/FX/BATT---------------

P00

absorb

 

00.0 hrs

float

 

13.6 vdc

float

 

24.0 hrs

time remaining

 

setpoint

 

 

time remaining

 

DOWN

UP

TOP PORT

DOWN

UP

TOP PORT

DOWN

UP

TOP PORT

STATUS/FX/BATT---------------

P00

STATUS/FX/BATT---------------

P00

STATUS/FX/BATT---------------

P00

refloat

 

12.5 vdc

equalize

 

14.4 vdc

equalize

 

00.0 hrs

setpoint

 

 

setpoint

 

 

time remaining

 

DOWN

UP

TOP PORT

DOWN

UP

TOP PORT

DOWN

UP

TOP PORT

STATUS/FX/BATT---------------

P00

batt temp.

 

 

255

(not in degree C/F)

 

DOWN

UP

TOP

PORT

STATUS/FX/BATT---------------------

Push <TOP> to return to the

end of battery menu

 

first METER screen.

UP TOP STATUS

Push <STATUS> to return

to the “choose category”

STATUS screen.

BATT(ERY) Screens

battery actual: battery voltage as measured by the Inverter

battery temp compensated: not active in the OBX-IC2024S-120/60 Inverter (reads the same as the battery actual reading)

absorb set point: charger set point for absorb recharging cycle

absorb time remaining: time remaining in absorb recharging cycle

float set point: battery set point for float recharging cycle

refloat set point: at this battery voltage, the charger restarts the float recharging cycle

equalize set point: charger set point for equalize recharging cycle

equalize time remaining: time remaining in equalize recharging cycle

batt temp: not active in the OBX-IC2024S-120/60 Inverter

The BATT MODE values cannot be changed in the STATUS screens.

28

Image 30
Contents OBX-IC2024S-120/60 Contact Information OutBack Power SystemsWarranty Summary DisclaimerTable of Contents OutBack Extreme Rugged Water Resistant Inverter/Charger Parts Included Unit DimensionsInverter Maintenance Required ConductorsInitial Inspection Use and StorageImportant Battery Instructions Safety and Human FactorsMounting System Protection AC and DC Grounding RequirementsWire Connections DC WiringConnection Torque Battery Wiring SERIES/PARALLEL ExampleBattery Wiring Examples for a 24-volt system Battery Wiring Examples for a 24-volt system AC Wiring Connector PlatePage Powering UP Locking collarMounting the Mate MATE2 System Controller and DisplayMate AT a Glance 13504pHOT Keys INV Hot KeyAC in Hot Key KeyPress Three Times SUM Status Setup ADV Soft KeysSummary Screens Srch Input Main Setup ScreensFxmate Down Grid GEN PortBack Type Delay Roll PG1 Sumry COM Main SETUP/MATE/SUMMARYBack Type Delay Roll SETUP/MATE/SUMMARY Clock CNT Glow PG2Back INC DEC SETUP/MATE/SUMMARY SETUP/MATE/SUM/TYPEBack INC DEC SETUP/MATE/SUM/TYPE Back INC DECBack INC DEC SETUP/MATE/SUMMARY/TYPE Communication Setup ScreensSETUP/MATE/SUMMARY/TYPE PG1 Sumry COM MainPG1 Sumry Comm Main Back Repoll PC DebugStatus Screens FX CC DC MainReading a Status Screen Status Meter Screens DefinitionStatus Battery Screens Pressing the Batt soft key brings up the first Batt screenStatus Error Screens Modes Meter Batt PG2 PG1 Error Warn PG3Status Warning Screens Status Disconnect Screens Disconnect ScreensInstallation Drawing Installation Check List OBX-IC2024S-120/60 Inverter/Charger Specifications Maximum AC Input Current Model Ampacity DC Breaker DC FuseInverter Default Values subject to change with upgrades VDC SystemMaintenance TroubleshootingYear Limited Warranty OutBack Extreme Inverter/Chargers2008-01-07 Address for warranty certificate Equipment OwnerPage Corporate Headquarters European Sales Office