MISC—MISCELLANEOUS
The MISCELLANEOUS screens display extra settings and technical information, some of which is useful for OutBack Power Systems Technical Services.
The Grid Tie (GT) value is sent from G- series inverter through the MATE and HUB for Grid Tie control communica- tions. GT X means MX60 is in grid tie mode and communicating with the G Series Inverter.
Each MPPT operation is a state. This number is useful for OutBack troubleshooting.
This is the duty cycle of the converter. At 50%, the PV terminals would be twice the battery voltage.
The battery temperature compensated Absorb (a) and Float (f) set points rise and fall with tem- perature. If no RTS is used, these settings will be the same as those in the charger setting screen.
GT State PWM% ChgT 255 07 50.0 005 Tmp Comp a14.4 f13.6
EXIT NEXT WIDE RSTRT
The Bulk/Absorb charge timer counts
up in Bulk and counts down in Absorb.
Press NEXT to | This soft key covers normal and |
Continue to the | limited battery compensation |
Force Bulk/Float | voltage range. Press WIDE and |
Screen. | LMIT mode appears, which limits |
| the Upper and Lower battery- |
| compensated voltage range. |
RSTRT forces the MX60 to restart or