The default state of the ERROR ALARM is On, meaning 12 VDC is present at the AUX terminal. If the MX60 has not charged the batteries for 26 hours or more continuously, the inaudible ERROR ALARM goes into an Off state. The ERROR ALARM is intended for remote locations to signal (e.g., a telecommunica- tion signal to a computer) when the MX60 has not recharged for 26 hrs or more. See MISCELLANEOUS Screen 3 Err for a display of the hourly countdown. Press the <NEXT> soft key to advance to the Diversion screen.

When external DC sources (wind, hydro) are directly connected to a battery bank, any excess power should be sent to a diversion load, such as a heating element. In Diversion, the user programs set points— from -5.0 volts to 5.0 volts relative to the Absorb, Float and EQ voltages—to activate the AUX MODE.

This is primarily an off-grid function. Pressing the <VOLT> soft key advances to the Absorb-Float-EQ screen to adjust the voltage set points.

Use this screen to establish the set points for starting and ending the AUX MODE relative to the Absorb, Float, and EQ voltages. The < - > and < + > soft keys set the Diversion set points. The <HYST> (Hysteresis) set point establishes when the AUX MODE becomes inactive after the battery voltage falls below the Relative Volts voltage minus the HYST value. After establishing these values, press the <BACK> soft key to return to the Diversion screen (see example on next page).

28

OutBack Power Systems Inc.

Image 28
Contents MX60 PV Mppt Warranty Summary Dear OutBack CustomerEN 61000-6-3 see January 29, 2007 REV 7.0 Software REV 5.10Table of Contents Battery Temperature Compensated Voltage SET Point Scope MX60 PV Mppt Maximum Power Point Tracking Charge ControllerIntroduction OutBack Power Systems Inc Personal Precautions Open Circuit VOLTAGE/WIRE and Disconnect Sizing Wire and Disconnect SizingCheck the PV array voltage before connecting it to the MX60 To 0 C 49 to 32 FField Wiring Connections and Surge Protection OutBack Power Systems Inc OutBack Power Systems Inc OutBack Power Systems Inc Battery System Voltage KEY to the Example DiagramsPowering UP OFF Screen this screen is initially blank at power upPassword Exitenter150 Enter +OutBack12V Power Systems MX60 Battery Voltage ScreenExit Enter Are you sure? 12 24 36 48 NOYesStatus Screen PV 005 Bat 12.500.0 a Watts Aux OffPV 087 Bat 12.5 05.0 a 32.9 a Watts 0412 Aux Off KWHrs 00.0 PV 113 Bat 12.5 00.0 a Watts 0000 Aux Off KWHrs SleepingMppt Accessing the Main Menu Charger Aux Light MiscLogging ExitCharger Setup Limit AbsorbAmps Volts 60.0 14.4 13.6AUX Mode Terminals. OFF indicates changes to the next mode VDCManual OffAUX Mode Path OutBack Power Systems Inc AUX Mode Exit Next on OFF AUX Mode Exit Next Vent FAN VoltsExit Next Time Volt PV Volts PV Trigger Off140 Back + Exit Next Time Volt AUX Mode PV TriggerExit Next Time Volt Hold Time Sec 01.1 Back +AUX Mode Error Alarm Exit Next Diversion OffAbsorb-Float-EQ Relative Volts 00.0 00.2 BackHold Delay 01.0 Time Seconds Example of DiversionDiversion Load and AUX Wiring Set-Up Illustrated Timer Low Batt DisconnectSec 001Exit Next Time Volt Disconnect Volts + ReConRE-CONNECT Volts 14.4 Back + DisVLogging Log2 Remote OffPress the Next soft key to view the Remote screen EQ-BATTERY Equalize BacklightBacklight Control Always Exit Auto on OFF Charger Aux *Light EQ Misc Optimize Logging Log2Battery Equalize Exit NEX -EQV +EQV Battery EqualizeExit Next -HRS +HRS Back Auto Start StopAuto Mode Count000 Exit DAY +DAYGT State PWM% ChgT 255 07 50.0 005 Tmp Comp a14.4 f13.6 MISC-MISCELLANEOUSExit Next Wide Rstrt WIDE/LMIT Battery Temperature Compensated Limits 13.2 Lower Limit 14.8 Back + DisV14.8 DisVExit Next Wide Rstrt Force Exit Next Float Bulk Force Float = fl oat cycle Force Bulk = bulk cycleMiscellaneous Screen PCBCFB AMP +AMPSnooze Mode Lowcutoff AdvancedCharger Aux Light Misc *Advanced Logging Log2 Exit Advanced MenuPark Mpp 77 % Voc Exit Next -Voc +Voc Mpp Range Limit %Voc min max Exit Next 1/2 90%Sweep Interval Minutes Exit Next -MIN MAX+ Advanced MenuVbatt Calibration 12.8v Exit Next -V +VLow Cutoff Amp Mppt Mode Auto Sweep Exit Next nonGT ModeThis screen allows the user to choose one of these modes Absorb Time Limits 000m 2hr Exit Next MIN+ MAX+Exit Data Logging Daily KWhours 00.0 Float time mins 0000 TotalKWh 0000Exit CLR +DAY -DAY Clear Back Totl DalyClearing Totals and Daily Stats Charger Aux Light Misc Advanced Logging Log2Pressing Back brings back the Logging screen Daily peak Battery voltage Operational modeLOG2 PkBatV Voc HiVoc 012.2 070.2 076.9PkBatV Voc HiVoc 012.2 070.2 Mppt Sunrise Exit Next Auto RestartSecondary LOG2 Screen 0000 float Tmin HighWatts Lo 13.2 Hi DCkWhThis value is the peak daily Watts seen by the MX60 MICRO-HYDRO, Wind TURBINE, and Fuel Cell Applications MICRO-HYDRO and Fuel Cell Systems Performance OptimizationOutBack Power Systems Inc Advanced Menu Micro-Hydro Advanced Menu Park Mpp 77 % VOC Exit Next -Voc +Voc PV 087 Bat 12.0 05.0 a 35.8A Watts This page Intentionally Left Blank Application Notes Calling the Factory for Assistance Warranty Dimensions Weight SpecificationsVoltage step down capability Limit Absorb Float Amps Volts 60.0 14.4 13.660.00 MX60 Efficiency vs. Input Power Graph 24V and 48V Battery System Efficiency CurveUnderstanding the Various Operational Modes OutBack Power Systems Inc OutBack Power Systems Inc OutBack Power Systems Inc MATE-DISPLAYED MX60 Status Mode Screens MATE-DISPLAYED MX60 Status Meter Screens MATE-DISPLAYED MX60 Status Setpt Setpoint Screens Troubleshooting Guide OutBack Power Systems Inc OutBack Power Systems Inc OutBack Power Systems Inc Typical Array Sizing Guide Standard vs. Australian Default Settings Standard version% Voltage Drop 12, 24 or 48 Volt Battery System Volt PV Array 80V MPP Typical Wire and Disconnect Sizing MX60 MULTI-STAGE Battery Charging OutBack Power Systems Inc Average = 95˚ F / 35˚ C Battery Temperature Compensated Volatge SET PointAverage = 86˚ F / 30˚ C Suggested Battery Charger SET Points TWO Year Limited Warranty Information OutBack Power Systems Inc EU Declaration of Conformity OWNER’S System Information Inverter/Chargers Product RegistrationProducts Covered Serial Number REV B