SECTION 2: CIRCUIT REQUIREMENTS
110/220V Operation
Serious personal injury could occur if you connect the machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so.
Amperage Draw
The Model G1010 features a 1⁄2 HP 110/220V motor that is prewired at 110V.
Motor Draw at 110V | 9 | Amps |
Motor Draw at 220V | 4.5 | Amps |
Circuit Requirements
Only connect your machine to a circuit that meets the requirements below. Always check to see if the wires and circuit breaker in your circuit are capable of handling the amperage draw from your machine, as well as any other machines that could be operating on the same circuit. If you are unsure, consult a qualified electrician.
110V Circuit | 15 Amp |
220V Circuit | 15 Amp |
Wiring for 220V
The Model G1010 can be rewired to operate on a 220V power source. The motor must be rewired according to the wiring diagram on the motor label. The wiring configuration can also be found on the inside of the motor wire cover, as well as on Page 38.
Plug Type
The Model G1010 comes prewired with a NEMA
2 for an example):
220V Plug & Receptacle | ||
|
|
|
|
|
|
|
|
|