L-GAGE® Q50 Analog Output Specifications
Sensing Beam | Wavelength: | Q50..V: 685 nm (typical) | Q50..: 880 nm (typical) |
| |||
| Beam Size: | Q50..V: 20 mm dia. (max.) | Q50..: 20 mm dia. (max.) |
| |||
Sensing Range | Q50AV: 50 to 150 mm |
| Q50A: 50 to 200 mm |
|
| ||
| Q50BV: 100 to 300 mm |
| Q50B: 100 to 400 mm |
|
| ||
Supply Voltage and Current | 15 to 30V dc (10% max. ripple); 70 mA max. (exclusive of load) |
|
| ||||
|
|
|
| ||||
Supply Protection Circuitry | Protected against reverse polarity and transient overvoltages |
|
| ||||
|
| ||||||
Output Configuration | |||||||
|
|
| |||||
Delay at | 2 seconds |
|
|
|
|
|
|
|
|
|
|
| |||
Output Protection | Protected against short circuit conditions |
|
|
| |||
|
|
|
|
| |||
Output Response Time | Analog Output | Average Interval | Update Rate | ||||
| Fast: |
|
| 4 milliseconds | 1 millisecond |
| 112 Hz |
| Slow: |
| 64 milliseconds | 4 milliseconds |
| 7 Hz | |
Resolution | See |
|
| ||||
| Q50B models: |
|
|
|
|
| |
| Target Distance: 200 mm Slow Response: 1 mm (max) Fast Response: 4 mm (max) | ||||||
| Q50A models: |
|
|
|
|
| |
| Target Distance: 100 mm Slow Response: 0.5 mm (max) Fast Response: 2 mm (max) | ||||||
|
|
|
|
| |||
Linearity | Q50B.. models: ±3 mm | Q50A.. models: ±1.5 mm |
|
| |||
|
|
|
| ||||
Color Sensitivity (typical) | See charts |
|
| ||||
|
|
|
|
|
|
| |
Temperature Effect | Q50B.. models: |
|
| From |
| ||
| From 0° to 50° C: 0.25 mm/° C |
| |||||
| Q50A.. models: |
|
|
|
|
| |
| From 0° to 50° C: 0.08 mm/° C | From |
| ||||
Remote and Speed Input | 15 kΩ |
|
|
|
|
|
|
Impedance |
|
|
|
|
|
| |
|
|
|
|
|
|
| |
Remote TEACH Input | To Teach: Connect gray wire to +5 to 30V dc |
|
| ||||
| To Disable: Connect gray wire to 0 to +2V dc (or open connection) |
|
| ||||
|
|
|
| ||||
Adjustments | Fast Speed: Connect black wire to +5 to 30V dc |
|
| ||||
| Slow Speed: Connect black wire to 0 to +2V dc (or open connection) |
|
| ||||
|
|
|
|
|
| ||
Indicators | Range LED |
| Green — Target is within sensing range |
|
| ||
| Indicator |
| Red — Target is outside sensing range |
|
| ||
| (Green/Red) |
| OFF — Sensor Power OFF |
|
| ||
| Teach/Output |
| Yellow — Target is within taught window limits |
|
| ||
| LED Indicator | OFF — Target is outside taught window limits |
|
| |||
| (Yellow/Red) |
| Red — Sensor is in TEACH mode |
|
| ||
Ambient Light Immunity | < 10,000 LUX |
|
|
|
|
|
|
|
|
|
| ||||
Construction | Housing: Molded ABS/Polycarbonate | Hardware: M3 hardware is included. | Window Lens: Acrylic | ||||
|
|
|
|
|
| ||
Environmental Rating | IEC IP67; NEMA 6P |
|
|
|
| ||
|
| ||||||
Connections | 2 m or 9 m | ||||||
| See page 416. |
|
|
|
|
| |
Operating Conditions | Temperature: | ||||||
|
| ||||||
Vibration and | All models meet Mil. Std. 202F requirements. Method 201A (Vibration: 10 to 60Hz max. double amplitude | ||||||
Mechanical Shock | 0.06”, maximum acceleration 10G). Also meets IEC |
| |||||
| 11 milliseconds duration, half sine wave. |
|
|
| |||
|
|
|
| ||||
Application Notes | Allow |
|
| ||||
|
|
|
|
|
|
|
|
Certifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Hookup Diagrams | MI09 (p. 534) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
260 More information online at bannerengineering.com