MEASUREMENT & INSPECTION
L-GAGE® LG5 and LG10 Specifications (cont’d)
Minimum Window Size | LG5: | 1.5 mm |
| LG10: 5 mm |
(Analog or Discrete) |
| |||
|
|
|
| |
|
|
|
| |
Discrete Output Hysteresis | LG5: Less than 0.2 mm |
| LG10: Less than 1.0 mm | |
|
|
|
| |
Color Sensitivity (typical) | LG5: Less than 75 µm |
| LG10: Less than 100 µm | |
|
| for white to dark gray ceramic target | for white to dark gray ceramic target | |
Temperature Effect | LG5: +/- 7 µm/° C |
| LG10: +/- 25 µm/° C | |
|
|
|
|
|
Remote TEACH and Laser | 18 kΩ min. (65 kΩ min. at 5V dc) |
|
| |
Control Input Impedance |
|
| ||
|
|
|
| |
Remote TEACH | To teach: Connect yellow wire to +5 to 30V dc |
| ||
| To disable: Connect yellow wire to 0 to +2V dc (or open connection) | |||
Adjustments | Response speed: Push button toggles between Slow, Medium, and Fast (see Output Response Time) | |||
| Window limits (analog or | |||
| may also be taught remotely using TEACH wire. |
| ||
| Analog output slope: The first limit taught is assigned to the minimum analog output (0V dc or 4 mA). | |||
|
| |||
Laser Control | To enable laser: Connect green wire to +5 to 30V dc | |||
| To disable laser: Connect green wire to 0 to +2V dc (or open connection) | |||
| 250 millisecond delay upon enable/disable |
| ||
|
| |||
Indicators | Green Power ON LED: Indicates when power is ON, overloaded output and laser status. | |||
| Yellow Output LED: Indicates when discrete load output is conducting. | |||
| Red Signal LED: Indicates when target is within sensing range and the condition of the received light | |||
| signal. |
|
|
|
| ||||
| (indicates Red for analog output, Green for discrete, and Yellow for simultaneous analog and discrete.) | |||
| Yellow Fast/Slow LEDs: Combination of 2 lights ON or OFF indicates 1 of 3 response speeds | |||
Construction | Housing: Zinc alloy | |||
| Cover plate: aluminum with painted finish |
| ||
| Lens: acrylic |
|
| |
Environmental Rating | IP67; NEMA 6 |
|
| |
|
| |||
Connections | 2 m or 9 m | |||
| disconnect. Mating QD cables are purchased separately. See page 416. | |||
Operating Conditions | Temperature: | Relative humidity: 90% at 50° C | ||
|
|
| ||
Vibration and | Vibration: 60 Hz, 30 minutes, 3 axes |
| ||
Mechanical Shock | Shock: 30G for 11 milliseconds, half sine wave, 3 axes | |||
Application Notes | For comparison, a white ceramic test surface has approximately 91% of the reflectivity of a white Kodak | |||
| test card with a matte finish. A dark gray ceramic test surface has approximately 11% of the reflectivity of | |||
| a white Kodak test card with a matte finish. (Allow | |||
|
|
|
|
|
Certifications |
|
|
|
|
|
|
| ||
Hookup Diagrams | NPN Models: MI06 (p. 533) | PNP Models: MI07 (p. 533) | ||
|
|
|
|
|
LIGHT ULTRASONIC MEASURING TEMPERATURE RADAR
GAUGINGLIGHT SCREENS
More information online at bannerengineering.com | 255 |