Banner L-GAGE manual GAGEQ45UR, Push-button setup, Analog and discrete output

Page 38

MEASUREMENT & INSPECTION

LIGHT GAUGING

LABEL&

 

ULTRASONIC

 

SLOT

 

LIGHT

 

lUMINESCENCE

MEASURING

 

 

SCREENS

&

 

COLOR

 

TEMPERATURE

 

LIGHT-TO-

 

PICK

 

RADAR

 

BRACKETS

PAGE 373

QD CABLES

5-Pin Euro +

5-Pin Mini

PAGE 415 & 421

U-GAGE®Q45UR

Remote Ultrasonic Sensors

Precise sensing for hard-to-access or difficult applications The U-GAGE®Q45UR remote ultrasonic sensors are available with analog or bipolar discrete output. They offer the same advanced features as standard Q45U models, with the additional choice of three remote sensing heads for use in confined or difficult environments.

Sensing head choices are 18 mm diameter threaded barrel housing in plastic or stainless steel, or ultra- compact plastic Flat-Pak.

Sensing range is 50 to 250 mm.

All models feature built-in temperature compensation and an operating temperature range from -25° to 70° C.

Environmental rating is IEC IP65 and NEMA 4.

Digital filtering provides immunity from random electrical and acoustic noise.

Push-button setup

Push-button TEACH-mode programming enables you to program exact sensing ranges and sensing windows, either by separately setting the lower and upper limits or by selecting the midpoint of a specific sensing window.

Analog and discrete output

Response time is programmed with switches in discrete models and with a potentiometer in analog models.

Adjustable response time is from 10 to 320 milliseconds for analog output sensors and 40 or 160 milliseconds for discrete output sensors.

Analog models feature a selectable positive or negative output slope.

Resolution is 0.1 mm for analog models and 0.6 mm for bipolar discrete models.

280 More information online at bannerengineering.com

Image 38
Contents 243 Q50Advanced time-of-flight technology at less cost GAGELT3Laser Distance Gauging Sensors Analog & discrete outputs, or dual-discrete models245 GAGELT3 SensorsLT3, 12-24V dc GAGELT3 Specifications GAGELT3 Specifications cont’d 247Discrete outputs or analog and discrete models GAGELT7Highly Accurate Time-of-Flight Laser Gauging Sensors Retroreflective models249 GAGELT7 SensorsLT7, 18-30V dc LT7PLVQGage LT7 Specifications Class 2 Visible Alignment Laser GAGELT7 Specifications cont’dClass 1 Infrared Sensing Laser 251Short-range Laser Sensors Push-button setup for custom-sized sensing windowsGagelg Extremely compact, self-contained design253 Gagelg SensorsGage LG5, 12-30V dc Gage LG5 and LG10 Specifications LG10, 12-30V dcGAGELG5 and LG10 Specifications cont’d 255Low-cost LED-based Distance Measurement Sensors Programmable featuresGAGEQ50 Reliable sensing for varied targets257 GAGEQ50 SensorsQ50 Discrete Output, 12-30V dc Q50 Discrete Output, 12-30V dc cont’d Q50 Analog Output, 15-30V dcGAGEQ50 Discrete Output Specifications 259Supply Voltage and Current GAGEQ50 Analog Output SpecificationsResolution Supply Protection Circuitry261 S18UGAGEQT50U Long-range Ultrasonic SensorGAGEQT50U Sensors Models Range Cable Output Data SheetOutput Models Range Cable Operation Mode Data Sheet GAGEQT50U, 10-30V dcGAGEQT50U DC Specifications 265 GAGEQT50U DC Specifications cont’dGAGEQT50U Universal Voltage Specifications Compact Ultrasonic Sensor On-board diagnosticsTwo housing styles Integrated push-button programmingGage S18U, 10-30V dc Gage S18U SpecificationsHousing Data Models Range Cable Output Configuration Sheet 267Minimum Window Size Switching Hysteresis GAGES18U Specifications cont’dRepeatability Temperature Effect WORLD-BEAMSensor QS18UUltrasonic 269Model Range Cable Options Output Sheet WORLD-BEAM QS18U SensorsWORLD-BEAMQS18U, 12-30V dc WORLD-BEAM QS18U Specifications 271Compact Sensors in Universal Housing GAGET30U273 Gage T30U SensorsT30U, 12-24V dc GAGET30U Specifications T30U, 15-24V dcSensing Performance Gage T30U Specifications cont’d275 GAGEQ45U Flexible Ultrasonic SensorsGAGEQ45U Analog Output, 15-24V dc GAGEQ45U SensorsQ45U Discrete Output, 12-24V dc Time SheetResponse Curves GAGEQ45U SpecificationsPerformance Specifications Output Protection CircuitryShort Range Min. target size GAGEQ45U Specifications cont’d279 Analog and discrete output Push-button setupGAGEQ45UR Gage Q45UR Discrete Output, 12-24V dc 281Product P/N Version GAGEQ45UR Remote Sensors SpecificationsGAGEQ45UR High-Gain Controllers 63060 Q45UR3BA63CQ6-63060Green flashing GAGEQ45UR Remote Sensors Specifications cont’d283 Red flashingOpposed Dual Range Sensors Popular patented housingGAGET18U Dual ranges and response timesResponse Data Models Range Cable Output Time Sheet Gage T18U SpecificationsGage T18U, 12-30V dc 285GAGET18U Specifications Cont’d Measuring Light Screens 287Two-Piece Measuring Light Screens Versatile mountingGAGEEZ-ARRAYLight Screen EZ-ARRAY Light Screens, 12-30V dc-5 mm Beam SpacingGAGEEZ-ARRAYSpecification Ultra-precise monitoring & inspection MINI-ARRAY291 Many options, yet easy to programEmitter/Receiver Housing Models Length L High-Resolution MINI-ARRAYSystemGage High-Resolution MINI-ARRAY Controllers 16-30V dc GAGEHigh-Resolution MINI-ARRAYController Specifications 293GAGEHigh-Resolution MINI-ARRAYSensor Specifications 295 Gage MINI-ARRAY Inspection and Profiling Light ScreensMAC16P-1 GAGEMINI-ARRAYControllers†, 16-30V dcMAC16N-1 297Sensors-9.5 mm Beam Spacing Housing Total ArraySensors-19.1 mm Beam Spacing Data Models Cable Length Beams Object Size Range SheetSystem Response Time GAGEMINI-ARRAYController Specifications299 Controller ProgrammingGage MINI-ARRAY Controller Specifications cont’d Gage MINI-ARRAY Controller with DeviceNet Specifications301 GAGEMINI-ARRAYSensor SpecificationsInterlaced Mode 12.7 mm Interlaced Mode 25.4 mm Minimum Object SensitivityAnalysis Measurement Control Mode SelectionAlarm/Trigger Blanking303 M18T Temperature SensorsM18T 14 M18T 8 M18T 6 M18T-Analog, 12-30V dc GAGEM18T SensorsM18T-Discrete, 10-30V dc Sensor Sensing Overall Output † Data ModelsGAGEM18T Specifications 305Radar-Based Adjustable-Field Sensor GAGEQT50R307 Model Max Range † Cable Telecom Approval Output Data SheetGage QT50R, 12-30V dc Gage QT50R Specifications