U-GAGE® Q45U Specifications
Sensing Range | Near limit: 100 mm min. | Long Range: Near limit: 250 mm min. |
| |
| Far limit: 1.4 m max. |
| Long Range: Far limit: 3.0 m max. |
|
| NOTE: The far limit may be extended on long range units, as far as 3.9 m for good acoustical targets | |||
| (hard surfaces with area greater than 100 cm2) |
| ||
|
|
| ||
Supply Voltage and Current | Discrete: 12 to 24V dc (10% max. ripple); 100 mA (exclusive of load) |
| ||
| Analog: 15 to 24V dc (10% max. ripple); 100 mA (exclusive of load) |
| ||
|
|
|
|
|
Ultrasonic Frequency | Long Range: 128 kHz |
| Short Range: 230 kHz |
|
|
|
| ||
Supply Protection Circuitry | Protected against reverse polarity and transient voltages. |
| ||
|
| |||
Output Protection Circuitry | Protected against false pulse on | |||
|
| |||
Output Configuration | Discrete: Bipolar: One current sourcing (PNP) and one current sinking (NPN) | |||
| Analog: One voltage sourcing and one current sourcing; one or the other output is enabled by internal | |||
| programming switch #2. |
|
| |
|
|
|
| |
Output Ratings | Discrete: 150 mA max. (each) |
|
| |
|
| |||
| ||||
| Analog: Voltage sourcing: 0 to 10V dc, 10 mA max. |
| ||
| Current sourcing: 4 to 20 mA, 1 to 500 Ω impedance |
| ||
|
|
|
| |
Performance Specifications | Analog resolution or | Short Range | Long Range | |
|
|
|
| |
| discrete repeatability: ± 0.1% of sensing distance | ± 0.1% of sensing distance | ||
| Analog Linearity: | (± 0.25 mm min.) | (± 0.5 mm min.) | |
| 1% of full scale | 1% of full scale | ||
| Temperature effect: 0.05% of sensing distance/ ° C with temp. comp. | 0.05% of sensing distance/° C | ||
| Min. window size: | 0.2% of sensing distance/ ° C without temp. comp. |
| |
| 10 mm |
| 25 mm | |
| Hysteresis (discrete output): 5 mm | 10 mm | ||
|
|
| ||
Response Curves | Short Range: See charts |
| ||
| Long Range: See charts |
| ||
Adjustments | The following may be selected by a | |||
| transparent |
| ||
| Discrete: Switch 1: Output normally open/normally closed (pump in/pump out) | |||
| Switch 2: High/Low level control mode or on/off presence sensing mode | |||
| Switch 3 & 4: Response speed selection (digital filter) |
| ||
| Analog: Switch 1: Output slope positive or output slope negative |
| ||
| Switch 2: Current output mode or voltage output mode |
| ||
| Switch 3: Loss of echo min/max mode or loss of echo Hold Mode | |||
| Switch 4: Loss of echo min/max default output value |
| ||
|
|
| ||
Indicators | Discrete: Three status LEDs: |
| ||
| Green ON steady: power to sensor is ON |
| ||
| Green flashing: output is overloaded |
| ||
| Yellow ON steady: outputs are conducting (Yellow LED also indicates programming | |||
|
|
| status during setup mode) |
|
| Red flashing: indicates relative strength of received echo |
| ||
| Analog: Three status LEDs: |
|
| |
| Green ON steady: power to sensor is ON |
| ||
| Green flashing: current output fault detected (the | |||
|
| been opened) |
| |
| Yellow ON steady: target is sensed within the window limits (Yellow LED also indicates | |||
|
|
| programming status during setup mode) |
|
| Red flashing: indicates relative strength of received echo |
| ||
| ||||
|
|
|
|
|
|
|
|
| More on |
|
|
|
| next page |