Lowrance electronic EP-60R installation instructions To customize Fuel Manager

Page 14

To customize Fuel Manager page:

1.With the Fuel Manager page displayed on the main display, press MENU, select CUSTOMIZE and press MENU.

2.Highlight USD (Fuel Used) and press MENU. If your unit is configured for more than one tank, the Select Tank menu will appear. (If your engine-tank configuration is set for one tank, you will be directed to the main display.)

3.Select the desired option and press MENU. You will be directed to the main display.

To check fuel flow accuracy:

1.Make sure your Fuel Remaining Source has been set to Fuel Flow then fill up the fuel tank connected to the EP-60R Fuel Flow you want to calibrate. Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press MENU.

2.Highlight FUEL MNGR and press MENU. Select REFILL T. and press MENU. If your unit is configured for more than one tank, the Select Tank menu will open. Select the tank you refilled and press MENU. (If your unit is configured for one tank, you will be taken directly to the Recalibration menu.)

3.The Recalibration (ReCal?) menu will appear with two options: Yes and No. Select NO and press MENU. The following message will appear: Hit Menu if Tank filled up.

4.Press MENU, which will direct you to the main display.

5.Take your boat out, but use only ONE engine — the engine connected to the fuel flow. Burn at least 5 gallons of fuel, then fill up the tank again, noting how much fuel was added to the tank. Check the Fuel Management page for the fuel used figure calculated by the EP- 60R Fuel Flow.

6.Compare the amount of fuel you added when you filled up the tank with the EP-60R Fuel Used figure. If the difference between these two numbers is greater than 3 percent, you need to calibrate the unit.

To calibrate a fuel flow:

7.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press MENU.

8.Highlight FUEL MNGR and press MENU. Select REFILL T. and press MENU. If your unit is configured for more than one tank, the Select Tank menu will open. Select the tank you refilled and press MENU. (If your unit is configured for one tank, you will be taken directly to the Recalibration menu.)

14

Image 14
Contents EP-60R Fuel Flow Tools and Supplies Installation Flow direction Engine From Tank Connecting to a Nmea 2000 Network Network Backbone and Network NodesAdding a Network Node Additional Network Information Page LMF-200 EP-60R Configuration & Calibration Boat SetupFuel Remaining Source FRem Src EP-60R Fuel Flow ConfigurationBoat Setup Reset Change Engine Active only with multiple-engine setting Page Fuel Flow Accuracy ResetEP-60R Fuel Flow Calibration To customize Fuel Manager Partial Fill Part Fill Reset CalibrationRefill Tank Refill T Reset Trip Fuel Used Rst trip f Economy Speed Source Eco spdReset Seasonal Fuel Rst Seas Fuel WarningScreen Rotation Engine Warnings AlarmsDisplaying data from fuel flow Customizing Pages To use reset command LMF-400 EP-60R Configuration & Calibration Fuel Remaining Source To unconfigure a fuel flow Change Engine active only with multiple-engine setting To add the Fuel Manager page to the display Enter Refill Tank Partial FillEconomy Speed Source Reset Trip FuelReset Seasonal Fuel Warning Displaying data from a fuel flow To customize Quad Digital Reset Values Display Unit EP-60R Configuration & Calibration Bus SetupEngine & Tank Configuration Nmea 2000 Devices List Device Configuration Menu Device Information and Device DataDevice Name Unconfiguring an EP-60R Fuel Flow LocationAdding Fuel to Tank Fuel Management MenuTank Operations If you filled up the tank Engine Operations To Reset Trip Nmea 2000 Alarms Alarm Status Tab Restore DefaultsPage Page Lowrance Electronics Full ONE-YEAR Warranty How to Obtain Service… For Lowrance 800-324-1356. For Eagle