Lowrance electronic EP-60R installation instructions To Reset Trip

Page 42

To Reset Calibration:

Choosing the Reset Calibration command will switch fuel flow calibration settings back to factory defaults.

1.Press MENU twice, select NMEA 2000 or NETWORKING and press ENTER.

2.Highlight FUEL MANAGEMENT and press ENTER. 3. Highlight to ENGINE SELECT and press ENTER. Select the desired engine and press ENTER.

4.Highlight RESET CALIBRATION and press ENTER. The following confirmation message will appear: Are you sure you wish to Reset Calibration? Select YES and press ENTER. Calibration settings for the selected fuel have been returned to factory defaults.

To Reset Trip:

The Reset Trip function allows you to reset to zero the running total of fuel used on a particular trip.

1.Press MENU twice, select NMEA 2000 or NETWORKING and press ENTER.

2.Highlight FUEL MANAGEMENT and press ENTER. The Fuel Management menu will appear.

3.To reset trip fuel used for a particular engine, highlight ENGINE SELECT and press ENTER. Select the desired engine or All Engines and press

ENTER.

4.Highlight RESET TRIP and press ENTER. The following confirmation message will appear: Are you sure you wish to Reset Trip?

5.Highlight YES and press ENTER. The Trip Fuel Used figure has been reset to zero.

To Reset Seasonal:

Your unit can track fuel usage not only for trips, but also for entire seasons. The reset seasonal command allows you to reset to zero the running total of fuel used during a season.

1.Press MENU twice, select NMEA 2000 or NETWORKING and press ENTER.

2.Highlight FUEL MANAGEMENT and press ENTER.

3.To reset seasonal trip fuel used for a particular engine, highlight

ENGINE SELECT and press ENTER. Select the desired engine or All Engines and press ENTER.

4.Highlight RESET SEASONAL and press ENTER. The following confirmation message will appear: Are you sure you wish to Reset Seasonal?

5.Highlight YES and press ENTER. The Seasonal Fuel Used figure has been reset to zero.

42

Image 42
Contents EP-60R Fuel Flow Tools and Supplies Installation Flow direction Engine From Tank Connecting to a Nmea 2000 Network Network Backbone and Network NodesAdding a Network Node Additional Network Information Page LMF-200 EP-60R Configuration & Calibration Boat SetupEP-60R Fuel Flow Configuration Boat Setup ResetFuel Remaining Source FRem Src Change Engine Active only with multiple-engine setting Page Reset EP-60R Fuel Flow CalibrationFuel Flow Accuracy To customize Fuel Manager Reset Calibration Refill Tank Refill TPartial Fill Part Fill Reset Trip Fuel Used Rst trip f Economy Speed Source Eco spdReset Seasonal Fuel Rst Seas Fuel WarningEngine Warnings Alarms Displaying data from fuel flowScreen Rotation Customizing Pages To use reset command LMF-400 EP-60R Configuration & Calibration Fuel Remaining Source To unconfigure a fuel flow Change Engine active only with multiple-engine setting To add the Fuel Manager page to the display Enter Refill Tank Partial FillReset Trip Fuel Reset SeasonalEconomy Speed Source Fuel Warning Displaying data from a fuel flow To customize Quad Digital Reset Values Display Unit EP-60R Configuration & Calibration Bus SetupEngine & Tank Configuration Nmea 2000 Devices List Device Configuration Menu Device Information and Device DataDevice Name Unconfiguring an EP-60R Fuel Flow LocationFuel Management Menu Tank OperationsAdding Fuel to Tank If you filled up the tank Engine Operations To Reset Trip Nmea 2000 Alarms Alarm Status Tab Restore DefaultsPage Page Lowrance Electronics Full ONE-YEAR Warranty How to Obtain Service… For Lowrance 800-324-1356. For Eagle