9.The Recalibration (The Recal?) menu will appear with two options: Yes and No. Select YES and press MENU.

NOTE:

If you do not have the fuel remaining source set to Eng/FFlow, the recalibration message will not appear.

10.The Filled Quantity window will appear. Use the UP and DOWN keys to input the amount of fuel you added to the tank and press MENU.

11.Repeat these steps for each fuel flow you want to calibrate.

Reset Calibration

The Reset Calibration command allows you to reset a fuel flow calibration back to factory defaults.

To Reset Calibration:

1.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press MENU.

2.Highlight B. DEVICES and press MENU. Select the fuel flow you want to reset and press MENU.

3.Select RST CAL from the fuel flow menu and press MENU. The following message will appear: Hit Menu to Rst the Cal.

4.Press MENU to set calibration back to factory default settings. To recalibrate the fuel flow, refer to the fuel flow calibration instructions in this section.

Refill Tank (Refill T)

Since the EP-60R is not connected to the tank, its fuel information is not automatically updated when the tank is filled up. You must use the Refill Tank command to ensure the fuel information in the EP-60R stays consistent with the amount of fuel actually in the tank.

To refill tank:

1.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press MENU. Highlight FUEL MNGR and press MENU.

2.Select REFILL T and press MENU. If your unit is configured for more than one tank, the Select Tank menu will appear with up to three options. (If you are using a single tank configuration, you will not see the Select Tank menu.)

3.Select the desired tank and press MENU. The following message will appear: Hit Menu if Tank filled up. Press MENU and you will be taken you back to the main display.

Partial Fill (Part Fill)

Since the EP-60R is not connected to the tank, its fuel information is not automatically updated when fuel is added to the tank. When you

15

Image 15
Contents EP-60R Fuel Flow Tools and Supplies Installation Flow direction Engine From Tank Network Backbone and Network Nodes Connecting to a Nmea 2000 NetworkAdding a Network Node Additional Network Information Page Boat Setup LMF-200 EP-60R Configuration & CalibrationEP-60R Fuel Flow Configuration Boat Setup ResetFuel Remaining Source FRem Src Change Engine Active only with multiple-engine setting Page Reset EP-60R Fuel Flow CalibrationFuel Flow Accuracy To customize Fuel Manager Reset Calibration Refill Tank Refill TPartial Fill Part Fill Economy Speed Source Eco spd Reset Trip Fuel Used Rst trip fFuel Warning Reset Seasonal Fuel Rst SeasEngine Warnings Alarms Displaying data from fuel flowScreen Rotation Customizing Pages To use reset command LMF-400 EP-60R Configuration & Calibration Fuel Remaining Source To unconfigure a fuel flow Change Engine active only with multiple-engine setting To add the Fuel Manager page to the display Enter Partial Fill Refill TankReset Trip Fuel Reset SeasonalEconomy Speed Source Fuel Warning Displaying data from a fuel flow To customize Quad Digital Reset Values Bus Setup Display Unit EP-60R Configuration & CalibrationEngine & Tank Configuration Nmea 2000 Devices List Device Information and Device Data Device Configuration MenuDevice Name Location Unconfiguring an EP-60R Fuel FlowFuel Management Menu Tank OperationsAdding Fuel to Tank If you filled up the tank Engine Operations To Reset Trip Nmea 2000 Alarms Restore Defaults Alarm Status TabPage Page Lowrance Electronics Full ONE-YEAR Warranty For Lowrance 800-324-1356. For Eagle How to Obtain Service…