Lowrance electronic EP-60R Economy Speed Source, Reset Trip Fuel, Reset Seasonal

Page 28

NOTE:

When using the Partial Fill command, you will only be able to input into the gauge, an amount of fuel less or equal to the fuel used figure. The unit will not allow you to enter a fuel amount greater than the fuel used figure.

4.Use the UP and DOWN keys to input the amount of fuel added to the tank and press ENTER. You will be taken back to the main display.

Economy Speed Source

The Economy Speed menu allows you to choose what speed source (Water Speed, Pitot Speed or Ground Speed) the LMF-400 will use to calculate Fuel Economy. Ground Speed (GPS) is the default speed source.

To change Economy Speed source:

1.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press ENTER. Select FUEL SETUP and press ENTER.

2.Highlight ECO SPEED SRC and press ENTER to open the Economy Speed menu. The menu has three options: Water Speed (Paddlewheel), Pitot Speed and Ground Speed (GPS).

3.Select the desired speed source and press ENTER. You will be taken back to the main display.

Reset Trip Fuel

The LMF-400 keeps a running total of fuel used for a trip. By using the Reset Trip command, you can reset to zero the running total of fuel used on a trip.

To reset trip fuel:

1.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press ENTER. Select FUEL SETUP and press ENTER.

2.Highlight RST TRIP FUEL and press ENTER. The Select Engine menu will appear with up to four options. (If you have one tank, the Press Enter to reset Trip Fuel (Step 3) message will appear.)

3.Select the desired engine or All Engines and press ENTER. The following message will appear: Press Enter to reset Trip Fuel.

4.Press ENTER, which will reset the trip fuel to zero and take you back to the main display.

Reset Seasonal

The LMF-400 keeps a running total of fuel used for a season. By using the Reset Seasonal command, you can reset to zero the running total of fuel used for a season.

28

Image 28
Contents EP-60R Fuel Flow Tools and Supplies Installation Flow direction Engine From Tank Connecting to a Nmea 2000 Network Network Backbone and Network NodesAdding a Network Node Additional Network Information Page LMF-200 EP-60R Configuration & Calibration Boat SetupBoat Setup Reset EP-60R Fuel Flow ConfigurationFuel Remaining Source FRem Src Change Engine Active only with multiple-engine setting Page EP-60R Fuel Flow Calibration ResetFuel Flow Accuracy To customize Fuel Manager Refill Tank Refill T Reset CalibrationPartial Fill Part Fill Reset Trip Fuel Used Rst trip f Economy Speed Source Eco spdReset Seasonal Fuel Rst Seas Fuel WarningDisplaying data from fuel flow Engine Warnings AlarmsScreen Rotation Customizing Pages To use reset command LMF-400 EP-60R Configuration & Calibration Fuel Remaining Source To unconfigure a fuel flow Change Engine active only with multiple-engine setting To add the Fuel Manager page to the display Enter Refill Tank Partial FillReset Seasonal Reset Trip FuelEconomy Speed Source Fuel Warning Displaying data from a fuel flow To customize Quad Digital Reset Values Display Unit EP-60R Configuration & Calibration Bus SetupEngine & Tank Configuration Nmea 2000 Devices List Device Configuration Menu Device Information and Device DataDevice Name Unconfiguring an EP-60R Fuel Flow LocationTank Operations Fuel Management MenuAdding Fuel to Tank If you filled up the tank Engine Operations To Reset Trip Nmea 2000 Alarms Alarm Status Tab Restore DefaultsPage Page Lowrance Electronics Full ONE-YEAR Warranty How to Obtain Service… For Lowrance 800-324-1356. For Eagle