EP-60R Fuel Flow Calibration
The factory calibration settings for the
NOTE:
The Fuel Remaining Source must be set to fuel flow for the unit to correctly display fuel level information. Follow the instructions below to ensure fuel flow (Eng/FFlow) has been selected as the Fuel Remaining Source. It is set to fluid level by default.
Fuel Flow Accuracy
To check fuel flow accuracy, add the Fuel Manager page to the page screen rotation and then customize it with Fuel Used data.
To add the Fuel Manager page to the display:
1.Press MENU, use the UP and DOWN keys to select PAGES and press ENTER. A menu will pop up with four options: Add Page, Remove Page, Page Scrolling and
2.Select ADD PAGE and press ENTER.
3.Highlight the Fuel Manager page and press ENTER. The following message will appear: Press Enter to add Fuel Manager.
4.Press ENTER, which will take you back to the main display, where the page you chose will be shown on the screen.
To customize the Fuel Manager page:
1.With the Fuel Manager page on the display, Press MENU, select CUSTOMIZE and press ENTER. The data menu will appear with three options: Top Data, Center Data and Bottom Data — each representing one of the three data boxes on the Fuel Manager page.
2.Select the desired data location and press ENTER. Highlight FUEL USED and press ENTER. If your unit is configured for more than one tank the Select Tank menu will appear.
NOTE:
If your unit is configured for a
3.Highlight the desired tank option and press ENTER. Press EXIT twice to return to the main display where Fuel Used data will be displayed on the Fuel Manager page.
To check fuel flow accuracy:
1.Make sure the Fuel Remaining Source has been set to Fuel Flow then fill up the tank connected to the fuel flow you want to calibrate.
25