Lowrance electronic installation instructions LMF-400 EP-60R Configuration & Calibration

Page 21

LMF-400: EP-60R

Configuration & Calibration

This section covers how to use the EP-60R Fuel Flow with a LMF-400 Multi-function gauge.

LMF-400 Multi-function Digital gauge.

Boat Setup

If this is the first time you have turned on your LMF-400, you will have to complete Boat Setup before you will be able to configure or calibrate your fuel flow. If you have already completed Boat Setup, skip ahead to the segment covering EP-60R Fuel Flow Configuration.

To execute Boat Setup:

1.With Boat Setup highlighted on the screen, press ENTER. A menu will appear, allowing you to choose the number of engines and fuel tanks on your vessel. The Boat Setup menu options are: 1 Eng/1 Tank,

1Eng/2 Tank, 2 Eng/1 Tank, 2 Eng/2 Tanks, 3 Eng/1 Tank or 3 Eng/3 Tanks.

2.Use the UP and DOWN keys to select the engine-tank configuration that applies to your vessel and press ENTER. After setting the engine/tank configuration, the Tank Size menu will appear with up to three options. (If you selected one tank during Boat Setup, you will be taken directly to the Setting Tank Size Window in Step 4.)

3.Select the desired tank and press ENTER, which will open the Setting Tank Size window.

4.Use the UP and DOWN keys to input the size of the tank and press ENTER. Repeat steps 3 and 4 for each of the remaining tanks.

5.After all tanks on your vessel have been set up, press EXIT repeatedly to return to the main display.

21

Image 21
Contents EP-60R Fuel Flow Tools and Supplies Installation Flow direction Engine From Tank Network Backbone and Network Nodes Connecting to a Nmea 2000 NetworkAdding a Network Node Additional Network Information Page Boat Setup LMF-200 EP-60R Configuration & CalibrationEP-60R Fuel Flow Configuration Boat Setup ResetFuel Remaining Source FRem Src Change Engine Active only with multiple-engine setting Page Reset EP-60R Fuel Flow CalibrationFuel Flow Accuracy To customize Fuel Manager Reset Calibration Refill Tank Refill TPartial Fill Part Fill Economy Speed Source Eco spd Reset Trip Fuel Used Rst trip fFuel Warning Reset Seasonal Fuel Rst SeasEngine Warnings Alarms Displaying data from fuel flowScreen Rotation Customizing Pages To use reset command LMF-400 EP-60R Configuration & Calibration Fuel Remaining Source To unconfigure a fuel flow Change Engine active only with multiple-engine setting To add the Fuel Manager page to the display Enter Partial Fill Refill TankReset Trip Fuel Reset SeasonalEconomy Speed Source Fuel Warning Displaying data from a fuel flow To customize Quad Digital Reset Values Bus Setup Display Unit EP-60R Configuration & CalibrationEngine & Tank Configuration Nmea 2000 Devices List Device Information and Device Data Device Configuration MenuDevice Name Location Unconfiguring an EP-60R Fuel FlowFuel Management Menu Tank OperationsAdding Fuel to Tank If you filled up the tank Engine Operations To Reset Trip Nmea 2000 Alarms Restore Defaults Alarm Status TabPage Page Lowrance Electronics Full ONE-YEAR Warranty For Lowrance 800-324-1356. For Eagle How to Obtain Service…