Lowrance electronic EP-60R installation instructions Adding a Network Node

Page 6

 

 

Backbone cable

Terminator at

Double T

(to rest of bus)

the end of the

 

connector

Cable from

backbone (bus)

 

 

sensor or

Cap for unused

 

display unit

 

 

connector

 

 

NMEA 2000 network node located at the end of a NMEA 2000 backbone.

NOTE:

If you have a double T Connector on your network that is not attached to a device, you must cap the unused connector with a NMEA 2000 cap. This will protect the pin connectors from corrosion. The NMEA 2000 cap looks like a terminator, but has "Cap" stamped into the connector housing.

All T connectors on your network probably will be connected to a device. If you want to add another node to a working network, add another T connector. T connectors may be purchased from LEI (ordering information appears on the back page of this booklet). If you are adding a Lowrance or LEI NMEA 2000 sensor, it will come with a T connector.

Adding a Network Node

You can add a node to any existing connection, anywhere along the network backbone. This connection could be between a T connector and a terminator, between two T connectors, between a T connector and a backbone extension cable or between two extension cables. Wherever you want to add the new node, separate the sockets of the existing connection and install the T connector between them. If you want to add a node at the end of the backbone (network bus) remove the terminator from the last connector, like the figure above. Install the new T connector and attach the terminator to the side of the connector.

6

Image 6
Contents EP-60R Fuel Flow Tools and Supplies Installation Flow direction Engine From Tank Connecting to a Nmea 2000 Network Network Backbone and Network NodesAdding a Network Node Additional Network Information Page LMF-200 EP-60R Configuration & Calibration Boat SetupEP-60R Fuel Flow Configuration Boat Setup ResetFuel Remaining Source FRem Src Change Engine Active only with multiple-engine setting Page Reset EP-60R Fuel Flow CalibrationFuel Flow Accuracy To customize Fuel Manager Reset Calibration Refill Tank Refill TPartial Fill Part Fill Reset Trip Fuel Used Rst trip f Economy Speed Source Eco spdReset Seasonal Fuel Rst Seas Fuel WarningEngine Warnings Alarms Displaying data from fuel flowScreen Rotation Customizing Pages To use reset command LMF-400 EP-60R Configuration & Calibration Fuel Remaining Source To unconfigure a fuel flow Change Engine active only with multiple-engine setting To add the Fuel Manager page to the display Enter Refill Tank Partial FillReset Trip Fuel Reset SeasonalEconomy Speed Source Fuel Warning Displaying data from a fuel flow To customize Quad Digital Reset Values Display Unit EP-60R Configuration & Calibration Bus SetupEngine & Tank Configuration Nmea 2000 Devices List Device Configuration Menu Device Information and Device DataDevice Name Unconfiguring an EP-60R Fuel Flow LocationFuel Management Menu Tank OperationsAdding Fuel to Tank If you filled up the tank Engine Operations To Reset Trip Nmea 2000 Alarms Alarm Status Tab Restore DefaultsPage Page Lowrance Electronics Full ONE-YEAR Warranty How to Obtain Service… For Lowrance 800-324-1356. For Eagle