8-2 Troubleshooting
Raster engraving appears sharp | ∙ | Dirty laser system | ∙ Clean all optics, rails, bearings and belts | |
on both ends of the engraving | ∙ | Something is loose | ∙ Check | |
but fuzzy in the middle | ∙ | System needs tuning |
| pulley, belt, and optics |
|
|
| ∙ Run “Tuning” feature in printer driver | |
| ∙ | Worn |
| version 4.17 and higher |
|
|
| ∙ Replace belt and/or drive gear, and run | |
|
|
|
| “Tuning” feature |
| ∙ Tickle setting too low | ∙ Adjust setting higher and recheck | ||
| ∙ | Faulty laser tube | ∙ | Replace laser tube |
Engraving does not appear as | ∙ | Graphic, graphic software, graphic | ∙ Check to see what has changed. Use | |
deep as it normally does |
| software setup, color palette, monitor |
| “Software Setup Guide” to properly setup |
|
| display colors, or driver settings have |
| the graphics software to work correctly |
|
| changed |
| with the laser system. Check driver |
|
|
|
| settings. |
| ∙ | Out of focus | ∙ | |
| ∙ Material or material density has | ∙ | Check material | |
|
| changed | ∙ Check power, speed, PPI, and DPI | |
| ∙ | Settings have changed |
| settings |
|
|
| ∙ Clean all optics, rails, bearings and belts | |
| ∙ | Dirty laser system | ∙ | Check and/or clean |
| ∙ Laser tube cooling fan filters are dirty | ∙ Check, clean, or adjust chiller | ||
| ∙ | Chiller not maintaining |
|
|
|
| temperature(water cooled versions only) | ∙ Adjust ambient temperature to within | |
| ∙ Ambient temperature not within |
| specifications | |
|
| specifications | ∙ Check and/or adjust laser beam | |
| ∙ | Laser beam out of alignment with the |
| alignment |
|
| optics | ∙ Check and/or adjust cone so that laser | |
| ∙ Air Assist cone misaligned (air assisted |
| beam is in center | |
|
| versions only) | ∙ | Replace laser tube |
| ∙ | Faulty laser tube |
|
|
Engraving is sharp, clear and at | ∙ | Out of focus | ∙ | |
a good depth on one side of the | ∙ | Dirty laser system | ∙ Clean all optics, rails, bearings and belts | |
table and fuzzy and shallow on | ∙ | Material is not level or varying in | ∙ Check focus point of material and | |
the opposite side of the table |
| thickness |
| different places, adjust height by |
|
|
|
| shimming material or using more |
|
|
|
| |
| ∙ Table is not level | ∙ Using the focus tool, focus directly on | ||
|
|
|
| the surface of the table in all four |
|
|
|
| corners. Table should be within |
|
|
|
| inches from one corner to the other. |
|
|
|
| Adjust if necessary. |
| ∙ Laser beam out of alignment with the | ∙ Check and/or adjust laser beam | ||
|
| optics |
| alignment |
| ∙ Air Assist cone misaligned (air assisted | ∙ Check and/or adjust cone so that laser |