Calibration Procedure
This procedure allows the operator to precisely adjust additive feed rates.
Caution! Never put hands or tools in or near the auger assembly when power is connected.
Do not wear gloves or loose clothing during calibration. The auger is exposed when the calibration or cleanout hatches are open.
Equipment Needed:
•Scale
•Sample container
•Timer- stopwatch, watch/clock w/second hand
Procedure
1.Close cleanout and calibration hatches.
2.Fill the additive supply hopper.
3.Weigh the empty sample container.
4.Swing open the calibration hatch near the main throat.
5.Set the controller to a desired RPM.
6.Place the sample container below the calibration hatch.
7.Hold the
Note: When the additive feeder is first powered up, the motor control needs to “warm up” for a few seconds by running the motor until it stabilizes. Subsequent operation will be instantaneous.
8.Position the empty scale container below the calibration hatch and hold the three- position motor switch in the Manual position for exactly one minute.
Note: If your additive feeder is equipped with the timer option, set the timer to one minute and put the
9.Weigh the sample container. Subtract the weight of the container and multiply by 60 to determine the pounds per hour feed rate.
10.Adjust the auger rpm and repeat the calibration process until the desired feed rate is achieved.
Note: To speed the calibration procedure, reduce trial and error auger rpm settings and zero in on the desired feed rate. Chart the calculated feed rates from a few rpm settings on graph paper. Draw a straight line between the coordinates to establish a customized feed rate curve for the actual operating conditions. A sample graph is provided on the next page; graph paper is included in the back of this manual for use with your feeding processes.