Additive Feeder Control Factory Defaults
WARNING! This procedure involves resetting a DIP switch within a live electrical enclosure. Only persons with the proper knowledge of and respect for working on energized electrical devices should attempt this procedure. Use extreme caution!
Note: Set the decimal point with DIP switch 4 first to avoid confusion when keying in the presets; for example, 300 and 30.0.
Figure 4: Additive Feeder Control Factory Defaults
DIP | Variable | |
Switch 1 | Auger RPM Constant | 30.0 |
Switch 2 | Program Minimum | 0.0 |
Switch 3 | Program Maximum | 70.0 |
Switch 4 | Decimal Place | 0.3 |
Switch 5 | Master/Follower Select | OFF |
| Standard Control | |
| Optional Extruder |
|
| Tracking Control | ON |
4-3 Shutting Down the Additive Feeder
1.Flip the motor switch to the OFF (center) position.
2.Turn the power OFF.
For long term shutdown, disconnect power and clean the additive feeder.