Sterling 882.00274.00 Shutting Down the Additive Feeder, Additive Feeder Control Factory Defaults

Page 32

Additive Feeder Control Factory Defaults

WARNING! This procedure involves resetting a DIP switch within a live electrical enclosure. Only persons with the proper knowledge of and respect for working on energized electrical devices should attempt this procedure. Use extreme caution!

Note: Set the decimal point with DIP switch 4 first to avoid confusion when keying in the presets; for example, 300 and 30.0.

Figure 4: Additive Feeder Control Factory Defaults

DIP

Variable

Pre-set

Switch 1

Auger RPM Constant

30.0

Switch 2

Program Minimum

0.0

Switch 3

Program Maximum

70.0

Switch 4

Decimal Place

0.3

Switch 5

Master/Follower Select

OFF

 

Standard Control

 

Optional Extruder

 

 

Tracking Control

ON

4-3 Shutting Down the Additive Feeder

1.Flip the motor switch to the OFF (center) position.

2.Turn the power OFF.

For long term shutdown, disconnect power and clean the additive feeder.

Additive Feeders

Chapter 4: Operation

31 of 50

Image 32
Contents SF Series Additive Feeders Parts and Service Department Shipping Information Table of Contents Troubleshooting Safety Symbols Used in this Manual SafetyHow to Use This Manual Wear Safety Glasses and Work Gloves Responsibility General ResponsibilityOperator Responsibility RememberMaintenance Responsibility Reporting a Safety DefectStandard Features Mechanical FeaturesFunctional Description Models Covered in This ManualOptions Electrical FeaturesController Features Accessories Fail Safe Operation Safety Devices and InterlocksSafety Circuit Standards Safety Device Lock-Outs Installation Supply System InstallationUncrating the Equipment Rigging and Placing the Additive FeederControl Relay Connection Main Power ConnectionElectrical Connections Setup Procedures Determining the Desired Feed Rate110 100 Equipment Needed Calibration ProcedureProcedure Examples Observed Feed RatesInitial Start-up Pre-Startup ChecksStarting Up the Additive Feeder Shutting Down the Additive FeederSwitches Indicator LightsOperation Start-upCounter Module Timer ModuleUsed as a Cycle Override Safety Timer Elapsed Time Module Set Point #2 Motor Control Bottom Low Level Regrind Feeder with Proximity SwitchDual Setpoint Control Operation 2 Component Applications Extruder Tracking Installation and Setup Extruder Tracking ControlExtruder Tracking Equation Desired Display Setting Field Control ProgrammingEquation Motor RPM = 25.2 X Auger RPMProgramming for Follower Operation Programming ModeViewing or Changing the Constant Viewing or Changing the Program Minimum Setting Viewing or Changing the Program Maximum SettingExiting Programming Mode and Returning to Run Mode Program Minimum SettingAdditive Feeder Control Factory Defaults Shutting Down the Additive FeederPhotocopy this page for your maintenance records MaintenancePreventative Maintenance Schedule Preventative Maintenance Material Cleanout/ChangeoverCorrective Maintenance Auger Assembly ChangeoverRemoving Auger Assembly Installing Auger AssemblyMotor Brush Replacement Replacement Motor Brush Part NumbersIntroduction TroubleshootingProblem Possible cause Corrective action Additive Feeders Troubleshooting Warranty AppendixOptional Components Technical Specifications Annex B InformationDrawings and Diagrams Additive Feeder Specifications and Overall DimensionsTypical Additive Feeder Controllers SET Point Spare Parts List Exploded Assembly Drawing Parts ListA0541292 Auger Assembly, 1/2 One Component Control Enclosure Parts Identification Two Component Control Enclosure Parts Identification Safety Tag Information Warranty ReturnsAdditive Feeder Safety Tags Returned Material PolicyAdditive Feeder Identification Serial Number Tag Technical AssistanceWorksheet for Charting Feed Rates Photocopy this page for your records