Viewing or Changing the Program Minimum Setting
1.Enter the programming mode, then flip DIP switch 2, Program Minimum Setting, to ON.
2.The current value for the lower limit FACTORY SETTING = 0 will appear in the LED display.
3.Use the Up or Down buttons to change the lower limit, as desired.
4.When finished, flip DIP switch 2 to OFF.
5.The display should read PROG.
Viewing or Changing the Program Maximum Setting
1.Enter the programming mode, then flip DIP switch 3, PROGRAM MAXIMUM SETTING to ON.
2.The current value for the upper limit FACTORY SETTING = 70 will appear in the LED display.
3.Use the Up or Down buttons to change the upper limit, as desired.
4.When finished, flip DIP switch 3 to OFF.
5.The display should read PROG.
Exiting Programming Mode and Returning to Run Mode
1.Make sure DIP switches 4, TIME/RATE MODE SELECT, and 5,
MASTER/FOLLOWER MODE SELECT are in the desired positions factory
Setting 4 = 1, 5 = OFF, ON FOR OPTIONAL EXTRUDER TRACKER CONTROLS BEFORE entering the RUN mode (DIP switch 7 OFF).
2.Make sure DIP switches 1 through 4 are OFF.
3.If satisfied with the programmed values, flip DIP switch 7 to OFF.
4.Control should begin to operate normally, using the values and modes selected.
Figure 3: DIP Switch Function Table
Switch 1 | Program Constant |
|
Switch 2 | Program Minimum Setting |
|
Switch 3 | Program Maximum Setting |
|
Switch 4 | Decimal Select | 0 – 4 = Decimal Points |
Switch 5 | Master/Follower Select | OFF = Master ON = Follower |
Switch 6 | Do Not Use – Set to OFF |
|
Switch 7 | Program/Run Select | OFF = Run ON = Program |
Switch 8 | Do Not Use – Set to OFF |
|
Additive Feeders | Chapter 4: Operation | 30 of 50 |