7-10. Troubleshooting
A. Welding
Trouble | Remedy |
|
|
No weld output. | Check control settings. |
|
|
| Check weld connections. |
|
|
| Disconnect equipment from auxiliary power receptacles during |
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, voltage regulator board PC8, intercon- |
| necting board PC2, and control board PC1. |
|
|
| If using remote control, be sure mode switch is in a position that provides output control at Remote 14 |
| receptacle (see Sections |
|
|
| Check, repair, or replace remote control. |
|
|
| Unit overheated. Allow unit to run so fan cools unit (see Section |
|
|
Ammeter and voltmeter do not work | Restart the engine. |
after unit has run out of fuel. |
|
|
|
Low weld output. | Check control settings. |
|
|
| Place V/A Control switch in Panel position, or move switch to Remote position and connect remote |
| amperage/voltage control to Remote 14 receptacle RC5 (see Section |
|
|
| Check and clean air cleaner as necessary (see Section |
|
|
| Check engine speed, and adjust if necessary (see Section |
|
|
| If using remote control, be sure mode switch is in a position that provides output control at Remote 14 |
| receptacle RC5 (see Sections |
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, voltage regulator board PC8, intercon- |
| necting board PC2, and control board PC1. |
|
|
| See engine manual. |
|
|
High weld output. | Check control settings. |
|
|
| Check engine speed, and adjust if necessary (see Section |
|
|
| Check for obstructed movement of throttle solenoid linkage. |
|
|
| Have Factory Authorized Service Agent check voltage regulator board PC8 and control board PC1. |
|
|
Weld output cannot be adjusted. | Check position of V/A Control switch (see Section |
|
|
| Have Factory Authorized Service Agent check voltage regulator board PC8 and control board PC1. |
|
|
Erratic weld output. | Check control settings. |
|
|
| Clean and tighten connections both inside and outside unit. |
|
|
| Check and secure lead connections to A/V control. |
|
|
| Be sure connection to work piece is clean and tight. |
|
|
| Remove excessive coils from weld cables. |
|
|
| Use dry, properly stored electrodes. |
|
|
| Check engine speed, and adjust if necessary (see Section |
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, voltage regulator board PC8, intercon- |
| necting board PC2, and control board PC1. |
|
|