Carrier GT-G, GT-S, GT-PX specifications Internally-mounted field installed Flow Controller

Page 14

GT-S

Application Flexibility

Eight Capacities 018, 024, 030, 036, 042, 048, and 060.

Voltage availability in 208-230/60/1.

Stackable cabinets.

Extended range operation (20-120°F EWT) and flow rates as low as 2.25 gpm per ton (geothermal closed loop operation).

Circuit breaker protected loop and hot water generator pumps.

Field selectable low temperature cut-out selection setting for geothermal closed loop operation.

Easily accessible electrical box for wiring.

Weather-resistent cabinet.

Internally-mounted (field installed) Flow Controller

Precharged refrigerant circuit with backseating service valves for quick installation.

Operating Efficiencies

ARI/ASHRAE/ISO 13256-1 ratings for heating COP’s, cooling EER’s and low water flow rates.

Operating and temperature range allow shorter loops.

Optional remoted-mounted hot water generator with internal pump generates hot water at considerable savings.

Rugged, super quiet, and highly efficient scroll compressors (rotary for size 018).

Oversized coaxial tube water to refrigerant heat exchangers operate at low liquid pressure drop.

Convoluted copper (and optional cupronickel) water tube functions efficiently at low-flow rates and provides freeze-damage resistance.

Service Advantages

Removable side and top panels for easy access to water/refrigerant circuits.

Low ambient temperature switch activates loop pump in extreme temperatures.

Solid state digital compressor module provides reliable lockout, diagnostic, and time delay functions.

High side loss-of-charge sensing reduces nuisance low pressure faults.

LED Fault and status indication with memory for easy diagnostics.

High and low pressure service ports in the refrigerant circuit.

Refrigerant sensing freeze protection for more accurate low temperature cut-out.

Factory Quality

All units are built on our Integrated Process Control Assembly System (IPCS).The IPCS is a unique state of the art manufacturing system that is designed to assure quality of the highest standards of any manufacturer in the water-source

industry. Our IPCS system:

-Verifies that the correct components are being assembled.

-Automatically performs special leak tests on all joints.

-Conducts pressure tests.

-Performs highly detailed run test unparalleled in the HVAC industry.

-Automatically disables packaging for a “failed” unit.

-Creates computer database for future service analysis and diagnostics from run test results.

Heavy gauge galvanized steel cabinets are epoxy powder coated for durable and long-lasting finish.

All refrigerant brazing is done in a nitrogen atmosphere.

All units are deep evacuated to less than 100 microns prior to refrigerant charging.

All joints are both helium and halogen leak tested to insure annual leak rate of less than 1/4 ounce.

Coaxial heat exchanger, refrigerant suction lines and all water lines are fully insulated to eliminate condensation problems in low temperature applications.

Noise Reduction features include: double isolation mounted compressors, compressor springs, insulated compressor compartment, and interior cabinet insulation using 1/2” coated glass fiber.

Safety features include: high pressure and loss of charge to protect the compressor; condensate overflow protection; low water temperature limit sensors to safeguard the coaxial heat exchanger and air coil; hot water high limit and low compressor discharge temperature switch provided to shut down the hot water generator when conditions dictate. Fault lockout enables emergency heat and prevents compressor operation until thermostat or circuit breaker has been reset.

12

Carrier Indoor & Outdoor Split Geothermal Heat Pumps - Rev.: 08/10/05

Image 14
Contents Geothermal Split Systems Carrier Page Table of Contents Maximum Comfort Geothermal AdvantagesHighest Efficiency Environmentally FriendlyClosed Loop Systems Ground Water SystemsRounding Out the Product Line Puron RefrigerantApplication Flexibility Other New FeaturesService Advantages Factory QualityOptions & Accessories Features and Benefits GT-GS Operating EfficienciesSingle-Stage Indoor Split R22 Systems GT-S Concept What is the GT-S?Why Paradigm Shift? Typical GT-S / Air Handler Installation Typical GT-S / Add-on Coil InstallationInternally-mounted field installed Flow Controller Copeland Scroll Compressor Rotary GT-PX 50YDS Performance Data English IP Units GT-PX 50YDS Performance Data Metric SI UnitsGT-GS 50YCS & GT-S 38WQS Performance Data English IP Units GT-GS 50YCS & GT-S 38WQS Performance Data Metric SI Units38WQS Nomenclature Model NomenclatureCooling GT-GS & GT-S Performance Correction FactorsAirflow Correction Factors Entering Air Correction Factors50YDS026 Part Load With FV4003 PSI EER HWC LAT COP50YDS026 Full Load With FV4003 EER HWC LAT COP50YDS038 Part Load With FV4005 50YDS038 Full Load With FV4005 PSI EER HWC LAT COP50YDS049 Part Load With FV4006 GT-PX 50YDS049 Full Load With FV400650YDS064 Part Load With FV4006 50YDS064 Full Load With FV4006 50YCS018 / 38WQS018 With GAH018 Cooling EAT 80/67 FCarrier 50YCS024 / 38WQS024 With GAH02450YCS030 / 38WQS030 With GAH030 EWT F GPM CFM PSI LAT COP HWC EER50YCS036 / 38WQS036 With GAH036 CFM PSI LAT COP HWC EER50YCS042 / 38WQS042 With GAH042 11050YCS048 / 38WQS048 With GAH048 50YCS060 / 38WQS060 With GAH060 2000 53.6GT-S 38WQS Physical Data GT-PX 50YDS Physical DataGT-GS 50YCS Physical Data GT-PX Dimensional Data GT-PX 50YDS Dimensional DataGT-GS Dimensional Data GT-GS 50YCS Dimensional DataGT-S Dimensional Data GT-S 38WQS Dimensional DataGT-GS 50YCS Electrical Data Electrical DataGT-PX 50YDS Electrical Data GT-S 38WQS Electrical DataTypical Thermostat Wiring Infinity / Evolution Controls Thermostat WiringTypical Thermostat Wiring, Two-Stage Units 3 Heat / 2 Cool Thermostat InstallationCXM LED And Alarm Relay Operations CXM ControlsSafety Features CXM Control CXM ControlsUnit Operation Diagnostic FeaturesStat signal CXM Control Start-up OperationGT-PX Split Wiring Diagram GT-GS Split Wiring Diagram GT-S Split Wiring Diagram Equipment Selection General22 Air Handler Characteristics Equipment SelectionSelecting Air Handler Air Handler Selection ExampleRefrigerant Circuit GT-PX Split 50YDS SeriesCasing & Cabinet ElectricalGT-GS GT-S Outdoor Split 38WQS Series Hose Kits field installed GT-PX & GT-GS only Thermostat field installedFlow Controller field installed Cooling TXV Kit field installed R-22 GT-GS & GT-S units onlyPage 7300 S.W th Street Oklahoma City, OK Phone Fax