Carrier GT-S, GT-G specifications GT-PX 50YDS Performance Data English IP Units

Page 16

Carrier

 

 

 

 

 

 

 

 

ARI/ISO/ASHRAE 13256-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GT-PX (50YDS) Performance Data - English (IP) Units

 

 

 

 

 

 

 

ARI/ISO/ASHRAE 13256-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

English (IP) Units

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water Loop Heat Pump

 

Ground Water Heat Pump

Ground Loop Heat Pump

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Load

Cooling 86°F

Heating 68°F

Cooling 59°F

Heating 50°F

Cooling 77°F

Heating 32°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity

EER

Capacity

 

COP

Capacity

EER

Capacity

 

COP

Capacity

EER

Capacity

 

COP

 

 

Btuh

Btuh/W

Btuh

 

Btuh

Btuh/W

Btuh

 

Btuh

Btuh/W

Btuh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

026

Full

24,700

15.0

31,400

 

5.3

28,600

23.2

25,600

 

4.7

26,400

18.0

19,500

 

3.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

026

Part

18,300

16.3

24,300

 

5.4

22,000

29.4

19,200

 

4.6

20,800

24.5

16,600

 

4.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

038

Full

35,900

14.8

44,700

 

5.0

40,100

21.4

35,900

 

4.5

37,300

16.7

27,000

 

3.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

038

Part

24,400

16.5

30,300

 

5.6

28,000

27.1

24,400

 

4.6

27,100

23.7

21,400

 

4.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

049

Full

48,100

14.6

59,400

 

5.2

53,900

20.9

47,700

 

4.6

50,200

16.6

37,200

 

4.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

049

Part

33,300

16.0

42,000

 

5.4

38,700

26.8

33,800

 

4.7

37,000

22.8

29,900

 

4.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

064

Full

56,900

14.5

74,000

 

4.7

63,800

19.2

58,800

 

4.3

59,500

15.3

45,700

 

3.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

064

Part

40,800

15.8

52,700

 

5.2

46,000

25.7

42,300

 

4.4

44,800

22.2

37,500

 

4.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GT-PX (50YDS) Performance Data - Metric (SI) Units

ARI/ISO/ASHRAE 13256-1

Metric (SI) Units

 

 

Water Loop Heat Pump

 

Ground Water Heat Pump

 

Ground Loop Heat Pump

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Load

Cooling 30°C

Heating 20°C

Cooling 15°C

Heating 10°C

Cooling 25°C

Heating 0°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity

EER

Capacity

 

COP

Capacity

EER

Capacity

 

COP

Capacity

EER

Capacity

 

COP

 

 

Watts

W/W

Watts

 

Watts

W/W

Watts

 

Watts

W/W

Watts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

026

Full

7,239

4.4

9,203

 

5.3

8,382

6.8

7,503

 

4.7

7,737

5.3

5,715

 

3.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

026

Part

5,363

4.8

7,122

 

5.4

6,448

8.6

5,627

 

4.6

6,096

7.2

4,865

 

4.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

038

Full

10,522

4.3

13,101

 

5.0

11,753

6.3

10,522

 

4.5

10,932

4.9

7,913

 

3.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

038

Part

7,151

4.8

8,880

 

5.6

8,206

7.9

7,151

 

4.6

7,943

6.9

6,272

 

4.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

049

Full

14,097

4.3

17,409

 

5.2

15,797

6.1

13,980

 

4.6

14,713

4.9

10,903

 

4.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

049

Part

9,760

4.7

12,309

 

5.4

11,342

7.9

9,906

 

4.7

10,844

6.7

8,763

 

4.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

064

Full

16,676

4.2

21,688

 

4.7

18,699

5.6

17,233

 

4.3

17,438

4.5

13,394

 

3.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

064

Part

11,958

4.6

15,445

 

5.2

13,482

7.5

12,397

 

4.4

13,130

6.5

10,991

 

4.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling capacities based upon 80.6°F DB, 66.2°F WB entering air temperature.

Heating capacities based upon 68°F DB, 59°F WB entering air temperature.

All ratings based upon 208V operation.

14

Carrier Indoor & Outdoor Split Geothermal Heat Pumps - Rev.: 08/10/05

Image 16
Contents Geothermal Split Systems Carrier Page Table of Contents Geothermal Advantages Highest EfficiencyMaximum Comfort Environmentally FriendlyClosed Loop Systems Ground Water SystemsRounding Out the Product Line Puron RefrigerantOther New Features Service AdvantagesApplication Flexibility Factory QualityOptions & Accessories Features and Benefits GT-GS Operating EfficienciesSingle-Stage Indoor Split R22 Systems Why Paradigm Shift? What is the GT-S?GT-S Concept Typical GT-S / Air Handler Installation Typical GT-S / Add-on Coil InstallationInternally-mounted field installed Flow Controller Copeland Scroll Compressor Rotary GT-PX 50YDS Performance Data English IP Units GT-PX 50YDS Performance Data Metric SI UnitsGT-GS 50YCS & GT-S 38WQS Performance Data English IP Units GT-GS 50YCS & GT-S 38WQS Performance Data Metric SI Units38WQS Nomenclature Model NomenclatureCooling GT-GS & GT-S Performance Correction FactorsAirflow Correction Factors Entering Air Correction Factors50YDS026 Part Load With FV4003 PSI EER HWC LAT COP50YDS026 Full Load With FV4003 EER HWC LAT COP50YDS038 Part Load With FV4005 50YDS038 Full Load With FV4005 PSI EER HWC LAT COP50YDS049 Part Load With FV4006 GT-PX 50YDS049 Full Load With FV400650YDS064 Part Load With FV4006 50YDS064 Full Load With FV4006 50YCS018 / 38WQS018 With GAH018 Cooling EAT 80/67 FCarrier 50YCS024 / 38WQS024 With GAH02450YCS030 / 38WQS030 With GAH030 EWT F GPM CFM PSI LAT COP HWC EER50YCS036 / 38WQS036 With GAH036 CFM PSI LAT COP HWC EER50YCS042 / 38WQS042 With GAH042 11050YCS048 / 38WQS048 With GAH048 50YCS060 / 38WQS060 With GAH060 2000 53.6GT-GS 50YCS Physical Data GT-PX 50YDS Physical DataGT-S 38WQS Physical Data GT-PX Dimensional Data GT-PX 50YDS Dimensional DataGT-GS Dimensional Data GT-GS 50YCS Dimensional DataGT-S Dimensional Data GT-S 38WQS Dimensional DataElectrical Data GT-PX 50YDS Electrical DataGT-GS 50YCS Electrical Data GT-S 38WQS Electrical DataThermostat Wiring Typical Thermostat Wiring, Two-Stage Units 3 Heat / 2 CoolTypical Thermostat Wiring Infinity / Evolution Controls Thermostat InstallationCXM LED And Alarm Relay Operations CXM ControlsSafety Features CXM Control CXM ControlsDiagnostic Features Stat signalUnit Operation CXM Control Start-up OperationGT-PX Split Wiring Diagram GT-GS Split Wiring Diagram GT-S Split Wiring Diagram Equipment Selection General22 Air Handler Characteristics Equipment SelectionSelecting Air Handler Air Handler Selection ExampleGT-PX Split 50YDS Series Casing & CabinetRefrigerant Circuit ElectricalGT-GS GT-S Outdoor Split 38WQS Series Thermostat field installed Flow Controller field installedHose Kits field installed GT-PX & GT-GS only Cooling TXV Kit field installed R-22 GT-GS & GT-S units onlyPage 7300 S.W th Street Oklahoma City, OK Phone Fax