Carrier GT-PX Other New Features, Application Flexibility, Service Advantages, Factory Quality

Page 7

Two-Stage Indoor Split Puron® Systems

Other New Features

Stylish two-tone look with textured black powder coat paint and stainless steel front access panel.

Liftout handle for front access panel.

Factory supplied (field-installed) filter drier for trouble free reliability.

Easy access low profile horizontal control box.

Double isolated compressor for quiet and vibration free operation.

Spring-mounted compressor for additional noise suppression.

Open Service-Friendly Cabinet (i.e, all components in compressor section can be serviced from the front).

Two-Stage operation for ultra high efficiencies and unsurpassed comfort.

Operating temperature range and high efficiency allow shorter loops.

Optional hot water generator with internal pump generates hot water at considerable savings.

Rugged and highly efficient next generation Copeland UltraTech™ scroll compressors provide the industry’s highest efficiencies and full capacity with reduced cycling losses.

Oversized coaxial tube water-to-refrigerant heat exchangers operate at low liquid pressure drop. Convoluted copper (and optional cupronickel) water tube functions efficiently at low-flow rates and provides freeze-damage resistance.

The GT-PX Series Split System has abundant features and industry leading efficiency.

Application Flexibility

Four Capacities 026, 038, 049, and 064.

Extended range operation (20-120°F EWT) and flow rates as low as 1.5 gpm per ton.

Compressor section match-ups for a variety of air handlers and add-on furnace coils for the ultimate in system and fuel type flexibility.

Precharged compressor section with back-seating service valves for quick installation.

Circuit breaker protected loop and hot water generator pumps.

Field selectable freeze protection setting for well or loop.

Puron® HFC 410A zero ozone depletion refrigerant.

Highest efficiencies for split systems in ARI/ISO/ ASHRAE/ANSI 13256-1 ratings for heating COP’s, cooling EER’s with low water flow rates.

Service Advantages

Removable panels - 3 for compressor section (plus removable top panel).

Low profile control box grants easy access to all internal components.

Factory supplied (field installed) liquid line filter/drier.

Brass swivel-type water connections for quick connection and elimination of wrenches or sealants during installation.

Bi-directional thermal expansion valve.

CXM control features status lights with memory for easy diagnostics.

Unit Performance Sentinel alerts homeowner of potential performance issues.

Circuit breaker protected 75VA control transformer.

High and low pressure service ports on refrigerant circuit.

Accurate refrigerant sensing freeze protection.

Factory Quality

All units are built on our Integrated Process Control Assembly System (IPCS).The IPCS is a unique state of the art manufacturing system that is designed to assure quality of the highest standards of any manufacturer in the water-source industry. Our IPCS system:

-Verifies that the correct components are being assembled.

Carrier Indoor & Outdoor Split Geothermal Heat Pumps - Rev.: 08/10/05

5

Image 7
Contents Geothermal Split Systems Carrier Page Table of Contents Environmentally Friendly Geothermal AdvantagesHighest Efficiency Maximum ComfortGround Water Systems Closed Loop SystemsPuron Refrigerant Rounding Out the Product LineFactory Quality Other New FeaturesService Advantages Application FlexibilityOptions & Accessories Features and Benefits Operating Efficiencies GT-GSSingle-Stage Indoor Split R22 Systems Why Paradigm Shift? What is the GT-S?GT-S Concept Typical GT-S / Add-on Coil Installation Typical GT-S / Air Handler InstallationInternally-mounted field installed Flow Controller Copeland Scroll Compressor Rotary GT-PX 50YDS Performance Data Metric SI Units GT-PX 50YDS Performance Data English IP UnitsGT-GS 50YCS & GT-S 38WQS Performance Data Metric SI Units GT-GS 50YCS & GT-S 38WQS Performance Data English IP UnitsModel Nomenclature 38WQS NomenclatureGT-GS & GT-S Performance Correction Factors CoolingEntering Air Correction Factors Airflow Correction FactorsPSI EER HWC LAT COP 50YDS026 Part Load With FV4003EER HWC LAT COP 50YDS026 Full Load With FV400350YDS038 Part Load With FV4005 PSI EER HWC LAT COP 50YDS038 Full Load With FV400550YDS049 Part Load With FV4006 50YDS049 Full Load With FV4006 GT-PX50YDS064 Part Load With FV4006 50YDS064 Full Load With FV4006 Cooling EAT 80/67 F 50YCS018 / 38WQS018 With GAH01850YCS024 / 38WQS024 With GAH024 CarrierEWT F GPM CFM PSI LAT COP HWC EER 50YCS030 / 38WQS030 With GAH030CFM PSI LAT COP HWC EER 50YCS036 / 38WQS036 With GAH036110 50YCS042 / 38WQS042 With GAH04250YCS048 / 38WQS048 With GAH048 2000 53.6 50YCS060 / 38WQS060 With GAH060GT-GS 50YCS Physical Data GT-PX 50YDS Physical DataGT-S 38WQS Physical Data GT-PX 50YDS Dimensional Data GT-PX Dimensional DataGT-GS 50YCS Dimensional Data GT-GS Dimensional DataGT-S 38WQS Dimensional Data GT-S Dimensional DataGT-S 38WQS Electrical Data Electrical DataGT-PX 50YDS Electrical Data GT-GS 50YCS Electrical DataThermostat Installation Thermostat WiringTypical Thermostat Wiring, Two-Stage Units 3 Heat / 2 Cool Typical Thermostat Wiring Infinity / Evolution ControlsCXM Controls CXM LED And Alarm Relay OperationsCXM Controls Safety Features CXM ControlCXM Control Start-up Operation Diagnostic FeaturesStat signal Unit OperationGT-PX Split Wiring Diagram GT-GS Split Wiring Diagram GT-S Split Wiring Diagram General Equipment SelectionEquipment Selection 22 Air Handler CharacteristicsAir Handler Selection Example Selecting Air HandlerElectrical GT-PX Split 50YDS SeriesCasing & Cabinet Refrigerant CircuitGT-GS GT-S Outdoor Split 38WQS Series Cooling TXV Kit field installed R-22 GT-GS & GT-S units only Thermostat field installedFlow Controller field installed Hose Kits field installed GT-PX & GT-GS onlyPage 7300 S.W th Street Oklahoma City, OK Phone Fax