Carrier GT-G, GT-S, GT-PX specifications Options & Accessories

Page 8

GT-PX

-Automatically performs special leak tests on all joints.

-Conducts pressure tests.

-Performs highly detailed run test unparalleled in the HVAC industry.

-Automatically disables packaging for a “failed” unit.

-Creates computer database for future service analysis and diagnostics from run test results.

Heavy gauge galvanized steel cabinets are epoxy powder coated for durable and long-lasting finish.

All refrigerant brazing is done in a nitrogen atmosphere.

All units are deep evacuated to less than 100 microns prior to refrigerant charging.

All joints are both helium and halogen leak tested to insure annual leak rate of less than 1/4 ounce.

Coaxial heat exchanger, refrigerant suction lines and all water lines are fully insulated to eliminate condensation problems in low temperature applications.

Noise Reduction features include: double isolation mounted compressors, compressor springs, insulated compressor compartment, and interior cabinet insulation using 1/2” coated glass fiber.

Safety features include: high pressure and loss of charge to protect the compressor; condensate overflow protection; low water temperature limit sensors to safeguard the coaxial heat exchanger and air coil; hot water high limit and low compressor discharge temperature switch provided to shut down the hot water generator when conditions dictate. Fault lockout enables emergency heat and prevents compressor operation until thermostat or circuit breaker has been reset.

Options & Accessories

Optional hot water generator with internally mounted pump.

Optional cupronickel coaxial heat exchanger.

Electronic thermostat.

Closed loop Flow Controller.

Electronic auto-changeover thermostat with 3- stage heat, 2-stage cool and indicator LED’s.

Hose kits.

Advanced Unit Controls With

Easy Diagnostics And

Unit Protection Sentinel Functions

Puron® HFC 410A Refrigerant

6

Carrier Indoor & Outdoor Split Geothermal Heat Pumps - Rev.: 08/10/05

Image 8
Contents Geothermal Split Systems Carrier Page Table of Contents Geothermal Advantages Highest EfficiencyMaximum Comfort Environmentally FriendlyClosed Loop Systems Ground Water SystemsRounding Out the Product Line Puron RefrigerantOther New Features Service AdvantagesApplication Flexibility Factory QualityOptions & Accessories Features and Benefits GT-GS Operating EfficienciesSingle-Stage Indoor Split R22 Systems GT-S Concept What is the GT-S?Why Paradigm Shift? Typical GT-S / Air Handler Installation Typical GT-S / Add-on Coil InstallationInternally-mounted field installed Flow Controller Copeland Scroll Compressor Rotary GT-PX 50YDS Performance Data English IP Units GT-PX 50YDS Performance Data Metric SI UnitsGT-GS 50YCS & GT-S 38WQS Performance Data English IP Units GT-GS 50YCS & GT-S 38WQS Performance Data Metric SI Units38WQS Nomenclature Model NomenclatureCooling GT-GS & GT-S Performance Correction FactorsAirflow Correction Factors Entering Air Correction Factors50YDS026 Part Load With FV4003 PSI EER HWC LAT COP50YDS026 Full Load With FV4003 EER HWC LAT COP50YDS038 Part Load With FV4005 50YDS038 Full Load With FV4005 PSI EER HWC LAT COP50YDS049 Part Load With FV4006 GT-PX 50YDS049 Full Load With FV400650YDS064 Part Load With FV4006 50YDS064 Full Load With FV4006 50YCS018 / 38WQS018 With GAH018 Cooling EAT 80/67 FCarrier 50YCS024 / 38WQS024 With GAH02450YCS030 / 38WQS030 With GAH030 EWT F GPM CFM PSI LAT COP HWC EER50YCS036 / 38WQS036 With GAH036 CFM PSI LAT COP HWC EER50YCS042 / 38WQS042 With GAH042 11050YCS048 / 38WQS048 With GAH048 50YCS060 / 38WQS060 With GAH060 2000 53.6GT-S 38WQS Physical Data GT-PX 50YDS Physical DataGT-GS 50YCS Physical Data GT-PX Dimensional Data GT-PX 50YDS Dimensional DataGT-GS Dimensional Data GT-GS 50YCS Dimensional DataGT-S Dimensional Data GT-S 38WQS Dimensional DataElectrical Data GT-PX 50YDS Electrical DataGT-GS 50YCS Electrical Data GT-S 38WQS Electrical DataThermostat Wiring Typical Thermostat Wiring, Two-Stage Units 3 Heat / 2 CoolTypical Thermostat Wiring Infinity / Evolution Controls Thermostat InstallationCXM LED And Alarm Relay Operations CXM ControlsSafety Features CXM Control CXM ControlsDiagnostic Features Stat signalUnit Operation CXM Control Start-up OperationGT-PX Split Wiring Diagram GT-GS Split Wiring Diagram GT-S Split Wiring Diagram Equipment Selection General22 Air Handler Characteristics Equipment SelectionSelecting Air Handler Air Handler Selection ExampleGT-PX Split 50YDS Series Casing & CabinetRefrigerant Circuit ElectricalGT-GS GT-S Outdoor Split 38WQS Series Thermostat field installed Flow Controller field installedHose Kits field installed GT-PX & GT-GS only Cooling TXV Kit field installed R-22 GT-GS & GT-S units onlyPage 7300 S.W th Street Oklahoma City, OK Phone Fax