Carrier GT-S specifications GT-PX 50YDS Electrical Data, GT-GS 50YCS Electrical Data

Page 40

Carrier

 

 

 

 

 

 

 

 

 

Electrical Data

 

 

 

 

 

 

 

 

 

 

 

 

GT-PX (50YDS) Electrical Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor

 

HWG

External

Total

Min

Max

 

Min

Max

Model

 

 

 

 

 

Pump

Pump

Unit

Circuit

Fuse/

 

Wire Ft.

RLA

 

LRA

 

Qty

 

AWG

 

 

 

FLA

FLA

FLA

Amps

HACR

 

(m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

026

10.3

 

52

 

1

0.4

4.0

14.7

17.2

25

 

10

110 (33.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

038

16.7

 

82

 

1

0.4

4.0

21.0

25.2

40

 

8

120 (36.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

049

21.2

 

96

 

1

0.4

4.0

25.5

30.8

50

 

6

160 (48.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

064

25.6

 

118

 

1

0.4

4.0

30.0

36.4

60

 

6

135 (41.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated Voltage of 208/230/60/1

Min/Max Voltage of 197/254

HACR circuit breaker in USA only

All fuses Class RK-5

Wire length based on one way measurement with 2% voltage drop

Wire size based on 60°C copper conductor

GT-GS (50YCS) Electrical Data

 

 

Compressor

 

HWG

External

Total

Min

Max

Min

Max

Model

 

 

 

 

 

Pump

Pump

Unit

Circuit

Fuse/

Wire Ft

RLA

 

LRA

 

Qty

AWG

 

 

 

FLA

FLA

FLA

Amps

HACR

(m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

018

9.0

 

42.0

 

1

0.40

4.0

13.4

15.7

20

12

80 (24.4)

 

 

 

 

 

 

 

 

 

 

 

 

 

024

10.3

 

56.0

 

1

0.40

4.0

14.6

17.2

25

10

110 (33.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

030

12.2

 

67.0

 

1

0.40

4.0

16.5

19.6

30

10

100 (30.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

036

13.5

 

73.0

 

1

0.40

4.0

17.8

21.2

30

10

90 (27.4)

 

 

 

 

 

 

 

 

 

 

 

 

 

042

16.5

 

95.0

 

1

0.40

4.0

20.9

25.0

40

8

120 (36.6)

 

 

 

 

 

 

 

 

 

 

 

 

 

048

18.3

 

109.0

 

1

0.40

4.0

22.7

27.3

45

6

180 (54.9)

 

 

 

 

 

 

 

 

 

 

 

 

 

060

25.0

 

169.0

 

1

0.40

4.0

29.3

35.6

60

6

140 (42.7)

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated Voltage of 208/230/60/1

Min/Max Voltage of 197/254

HACR circuit breaker in USA only

All fuses Class RK-5

Wire length based on one way measurement with 2% voltage drop

Wire size based on 60°C copper conductor

GT-S (38WQS) Electrical Data

 

 

Compressor

 

HWG

Ext Loop

Total

Min

Max

Min

Max

Model

 

 

 

 

Crank-

Pump

Pump

Unit

Circuit

Fuse/

Wire Ft

RLA

LRA

Qty

 

AWG

 

 

FLA

FLA

FLA

Amps

HACR

(m)

 

 

case

 

 

 

 

 

 

 

 

 

 

 

 

 

018

7.1

38.0

1

 

N/A

0.40

4.0

11.2

12.9

20

12

90 (27.4)

 

 

 

 

 

 

 

 

 

 

 

 

 

024

10.3

56.0

1

 

0.17

0.40

4.0

14.4

17.0

25

10

120 (36.6)

 

 

 

 

 

 

 

 

 

 

 

 

 

030

12.2

67.0

1

 

0.17

0.40

4.0

16.4

19.4

30

10

100 (30.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

036

13.5

73.0

1

 

0.17

0.40

4.0

17.6

21.0

30

10

90 (27.4)

 

 

 

 

 

 

 

 

 

 

 

 

 

042

16.5

95.0

1

 

0.17

0.40

4.0

20.7

24.8

40

8

120 (36.6)

 

 

 

 

 

 

 

 

 

 

 

 

 

048

18.3

109.0

1

 

0.17

0.40

4.0

22.5

27.1

45

8

110 (33.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

060

28.9

169.0

1

 

0.29

0.40

4.0

33.1

40.4

60

6

120 (36.6)

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated Voltage of 208/230/60/1

Min/Max Voltage of 197/254

HACR circuit breaker in USA only

All fuses Class RK-5

Wire length based on one way measurement with 2% voltage drop

Wire size based on 60°C copper conductor

38

Carrier Indoor & Outdoor Split Geothermal Heat Pumps - Rev.: 08/10/05

Image 40
Contents Geothermal Split Systems Carrier Page Table of Contents Geothermal Advantages Highest EfficiencyMaximum Comfort Environmentally FriendlyClosed Loop Systems Ground Water SystemsRounding Out the Product Line Puron RefrigerantOther New Features Service AdvantagesApplication Flexibility Factory QualityOptions & Accessories Features and Benefits GT-GS Operating EfficienciesSingle-Stage Indoor Split R22 Systems Why Paradigm Shift? What is the GT-S?GT-S Concept Typical GT-S / Air Handler Installation Typical GT-S / Add-on Coil InstallationInternally-mounted field installed Flow Controller Copeland Scroll Compressor Rotary GT-PX 50YDS Performance Data English IP Units GT-PX 50YDS Performance Data Metric SI UnitsGT-GS 50YCS & GT-S 38WQS Performance Data English IP Units GT-GS 50YCS & GT-S 38WQS Performance Data Metric SI Units38WQS Nomenclature Model NomenclatureCooling GT-GS & GT-S Performance Correction FactorsAirflow Correction Factors Entering Air Correction Factors50YDS026 Part Load With FV4003 PSI EER HWC LAT COP50YDS026 Full Load With FV4003 EER HWC LAT COP50YDS038 Part Load With FV4005 50YDS038 Full Load With FV4005 PSI EER HWC LAT COP50YDS049 Part Load With FV4006 GT-PX 50YDS049 Full Load With FV400650YDS064 Part Load With FV4006 50YDS064 Full Load With FV4006 50YCS018 / 38WQS018 With GAH018 Cooling EAT 80/67 FCarrier 50YCS024 / 38WQS024 With GAH02450YCS030 / 38WQS030 With GAH030 EWT F GPM CFM PSI LAT COP HWC EER50YCS036 / 38WQS036 With GAH036 CFM PSI LAT COP HWC EER50YCS042 / 38WQS042 With GAH042 11050YCS048 / 38WQS048 With GAH048 50YCS060 / 38WQS060 With GAH060 2000 53.6GT-GS 50YCS Physical Data GT-PX 50YDS Physical DataGT-S 38WQS Physical Data GT-PX Dimensional Data GT-PX 50YDS Dimensional DataGT-GS Dimensional Data GT-GS 50YCS Dimensional DataGT-S Dimensional Data GT-S 38WQS Dimensional DataElectrical Data GT-PX 50YDS Electrical DataGT-GS 50YCS Electrical Data GT-S 38WQS Electrical DataThermostat Wiring Typical Thermostat Wiring, Two-Stage Units 3 Heat / 2 CoolTypical Thermostat Wiring Infinity / Evolution Controls Thermostat InstallationCXM LED And Alarm Relay Operations CXM ControlsSafety Features CXM Control CXM ControlsDiagnostic Features Stat signalUnit Operation CXM Control Start-up OperationGT-PX Split Wiring Diagram GT-GS Split Wiring Diagram GT-S Split Wiring Diagram Equipment Selection General22 Air Handler Characteristics Equipment SelectionSelecting Air Handler Air Handler Selection ExampleGT-PX Split 50YDS Series Casing & CabinetRefrigerant Circuit ElectricalGT-GS GT-S Outdoor Split 38WQS Series Thermostat field installed Flow Controller field installedHose Kits field installed GT-PX & GT-GS only Cooling TXV Kit field installed R-22 GT-GS & GT-S units onlyPage 7300 S.W th Street Oklahoma City, OK Phone Fax