Baum Bros. Imports 26.4 manual Index, K5A, K5B

Page 2

Index

page

Control Panel / Operating Elements

E - 4

Explanation of Pictographs on the Display

E - 5

Chapter Survey

E - 6

Introduction

E - 7

Technical Data/Machine Layout/Transport and Installation

K1

- 1

of the Machine/Safety Relevant Machine Elements

K1 - 1

Machine Layout

K1

- 2

Plan

K1

- 3

Transport and Installation of the Machine

K1

- 4

Place of Installation

K1

- 4

After the Installation of the Machine

K1

- 4

Power Supply

K1

- 5

Type plate

K1

- 6

Safety Relevant Machine Elements

K1

- 7

Accident prevention warning labels at BAUM cutters

K1

- 8

Safety Relevant Machine Elements

K1

- 8

Safety Signs

K1

- 9

Technical Data

K1 - 10

Permissible Environmental and Operating Conditions

K1 - 10

Hydraulic Data

K1 - 10

Safety Precautions

K1 - 10

Residual Risk

K1 - 10

Technical Data

K1 - 11

Safety

K2

- 1

Start Up

K3

- 1

Switching Machine ON

K3

- 2

Turning Machine OFF

K3 - 2

Measurement Display and Measurement System

K3 - 3

Manual Operation

K4

- 1

Cutting Line Indicator, Mechanical with Clamp

K4

- 2

Cutting Line Indicator, Optical

K4

- 2

Setting of Measurements (Backgauge Movement) by Hand

K4 - 2

Clamp Pressure Adjustment

K4 - 3

Setting the Clamping Time

K4

- 3

Clamping and Cutting

K4 - 3

Light Barrier

K4

- 4

Continuation: Light Barrier

K4 - 5

Clamping with False Clamp Plate

K4 - 6

Automatic Operation

K5A - 1

Introduction

K5A - 2

Basic Displays

K5A - 3

Basic Display: Program Data

K5A - 3

Contin.: Basic Display: Program Data

K5A - 4

Basic Display: Program Information

K5A - 5

Basic Display: Program Directory

K5A - 6

Basic Display: Main Menu (Function Survey)

K5A - 7

Menu "Help":

K5A - 7

Explanation of pictographs

K5A - 7

Cursor Movement in Basic Display

K5A - 8

Automatic Backgauge Adjustment through Numerical Keyboard

K5A - 9

Deletion of a Wrong Input

K5A - 10

Moving Backgauge to a Nominal Position (Positioning)

K5A - 10

Input Error: Value of Nom. Backgauge Position too Low/High

K5A - 10

Selection of a Free Program/Display of the Next Free Program

K5A - 11

Selecting a Program

K5A - 12

Continuing: Selecting a Program

K5A - 13

Storage of Measurements

K5A - 14

Setting Up a Cutting Program, Example 1

K5A - 15

Setting Up a Cutting Program, Example 2

K5A - 16

Correction of an Input Error

K5A - 17

Automatic ON/OFF

K5A - 18

Running a Cutting Program

K5A - 19

Storing of Program Informations

K5A - 20

Deletion of a Step Number

K5A - 21

Deletion of One/Several Program(s)

K5A - 22

Deletion of Complete Memory

K5A - 23

Inserting of Measurements into a Program

K5A - 24

Storing of Measurements According to Printed Image

K5A - 24

Calculator Functions

K5A - 25

Negative Sign

K5A - 26

Using Backgauge Position of Calculations

K5A - 26

Machine Functions and Additional Functions (Menu Keys)

K5B - 1

Machine Function: Main Menu (Function Survey)

K5B - 2

Menu "Help":

K5B - 2

Explanation of pictographs

K5B - 2

Service

K5B - 3

E - 2

Image 2
Contents Baumcut 26.4 Programmable K5B IndexK5A K5C MaintenanceIndex K5DProgrammable Control Panel / Operating ElementsExplanation of Pictographs on the Display Chapter Survey Chapter SurveyCopyright IntroductionPlease pay special attention to the following information Page Page Machine Layout Dimensions in mm PlanAfter the Installation of the Machine Transport and Installation of the MachinePlace of Installation Case of ComplaintsPower Supply Energy lead wireType Plates Type plate Type plateWorking Area of Operating Personnel Safety Relevant Machine ElementsSafety Auxiliary Tools Placement of the warning label Durability Placement of the warning labels Label 1 Label 2 Label 3Safety Signs Safety Signs / Warning SignsPermissible Environmental and Operating Conditions Technical DataSafety Precautions Hydraulic DataVoltage supply single phase AC 210 240, 60Hz Voltage supply 3 phase 360 420V, 50/60HzVoltage supply single phase AC 200 240, 50Hz Page Safety Symbol Page Electrical energy Start Up To prevent a start-up of the machine Switching Machine onTurning Machine OFF Measurement Display and Measurement System Program Data DisplayPage Manual Operation Cutting Line Indicator, Optical Setting of Measurements Backgauge Movement by HandCutting Line Indicator, Mechanical with Clamp Actuate toggle switch 8 at main switch plateClamping and Cutting Clamp Pressure AdjustmentSetting the Clamping Time To continue the cutting process Light BarrierInterference into the light curtain causes Meaning of LEDs in display unit Continuation Light BarrierD2 D4 D1 D3 Removing of false clamp plate Clamping with False Clamp PlateAttaching false clamp plate Automatic Operation Functions of the menu keys Key Main menu Function Survey Program Data Key Main Menu Function Survey Basic DisplaysBasic Display Program Data Program Information Key Program DirectoryContin. Basic Display Program Data Basic Display Program Information Press key5VAC Basic Display Program Directory1575 Other input modes in this displayBasic Display Main Menu Function Survey Press menu keyCursor Movement in Basic Display Program data display After 1. inputinput section shows Automatic Backgauge Adjustment through Numerical KeyboardMeasurement input in inches Backgauge movesMoving Backgauge to a Nominal Position Positioning Input Error Value of Nom. Backgauge Position too Low/HighDeletion of a Wrong Input Deletion of a wrong inputDisplay example Possible in all 4 basic monitor displaysMake selection Program Number Example Selecting a ProgramAccording to order number Continuing Selecting a Program Numerical keyboardStorage of Measurements Only in Program data displayKey input Setting Up a Cutting Program, ExampleTwo side trim on size DIN A3 Untrimmed size 31 x 43 cm Running the programCall program 5A Enter Correcting after storing Correction of an Input ErrorCorrecting before storing Positioning check in automatic operation Automatic ON/OFFAutomatic OFF Made GO to PositionAfter cut Example Setting a cutting program, exampleRunning a Cutting Program Storing Order Storing of Program InformationsPress key Program Information End of information inputDeletion of a Step Number Deletion of One/Several Programs PRO Deletion of Complete MemoryInserting of Measurements into a Program Storing of Measurements According to Printed ImageConditionsAutomatic OFF Overflow IndicatorCalculator Functions To set backgauge to a calculated sizeNegative Sign Using Backgauge Position of CalculationsSwitching the function off Additional Functions Machine Functions and Additional Functions Menu KeysMachine Functions Machine Function Main Menu Function Survey Key Main Menu Key Main Menu includes the following functionsSelect Main Menu Funtion survey ServiceSelect Language / Measuring Unit Select function Language or Measuring UnitSelect function Select Knife compensation Knife CompensationCalibration to compensate for knifes of different thickness Knife changeAdjust time Resting Time for Knife at BDCMaintenance Cut Counter Set counterCalculate basic position Preset FunctionsSelection of Main Menu Correction of Current Position Possible funtions in Auxiliary mode Continuing Preset FunctionsSelect function Preset functions Scan Reference Positionj Abortion of reference runAdjustment of Display Contrast End of input with keyPossibility of edge trim preadjusting Block ProgrammingSetting up a Block Programming Example Variation 1, selection 1 Angular cutDeletion of an input parameter with Block Programming Selection of an input parameter with Block ProgrammingCorrection of an input parameter with Block Programming Four trim cut Example Variation 1, selection Four trim cutEnter Edge trim Example Variation 3, selection 3 Four trim cut with labels Four trim cut with labelsBlock Programming Four-side trim with labels and trim cuts Right-hand lay side Enter outside trim Enter trimout measurementBlock Programming Menu Key Additional Functions Erase Additional Function Storage of Additional Functions with Cut SizeSubsequent Storing of Additional Functions Ejector OFF List of Additional FunctionsAdditional function Jogging mark Operation K5C Menu Key Auxiliary Functions After program generation Cut and RecordSheet Size Tables Graphics OFF Subtraction Repetition UnitQuitt the function K5D Menu Key Machine Parameters Prepressure Time Adjustment of pre-pressure timeAdjustment of BDC time Make selectionKnife Change Deposit knife in knife box!! Remove knife guard Knife Change Mounting the knifeAdjusting the knife Adjustment of knife pre-tensionKnife adjustment Tighten up all knife boltsInserting of cutting stick Changing of cutting stickRemoving of cutting stick Normal Turn overPage Malfunctions / Breakdowns Electrical Malfunctions/Breakdowns Remedy for machine malfunctionsStart Up Breakdown Scan Reference Point/Auxiliary Mode Machine functions possible in Auxiliary ModeKnife bar or clamp not in top dead centre Breakdown Knife bar stops beneath the upper dead centreBreakdown Clamp stops beneath the upper dead centre Maintenance Basic information about servicing and maintenance work Quantity liters 22,5 Lubrication intervals weeklyCleaning of Display Hrs. per day equalPage Baum USA Service Mr./MrsFax 937/492-7280