Baum Bros. Imports 26.4 manual Menu Key Additional Functions

Page 79

5.0 Automatic Operation

Menu Key: Additional Functions

Key "Additional Functions"

Key "Additional Functions" includes the following operations*:

Jogging mark

Ejector OFF

Help

The running of cutting programs can be further automated by using Additional Functions.

The Additional Function can be selected on the operating panel under menu key "Additional Functions"

It is possible to store several Additional Functions into one step number.

Jogging mark

Ejector OFF

Help

 

Explanation of

 

pictographs

* Technical alterations reserved!

K5C - 1

Image 79
Contents Baumcut 26.4 Programmable K5A IndexK5B K5D MaintenanceIndex K5CControl Panel / Operating Elements ProgrammableExplanation of Pictographs on the Display Chapter Survey Chapter SurveyPlease pay special attention to the following information IntroductionCopyright Page Page Machine Layout Plan Dimensions in mmCase of Complaints Transport and Installation of the MachinePlace of Installation After the Installation of the MachineEnergy lead wire Power SupplyType plate Type Plates Type plateSafety Auxiliary Tools Safety Relevant Machine ElementsWorking Area of Operating Personnel Placement of the warning labels Label 1 Label 2 Label 3 Placement of the warning label DurabilitySafety Signs / Warning Signs Safety SignsHydraulic Data Technical DataSafety Precautions Permissible Environmental and Operating ConditionsVoltage supply single phase AC 200 240, 50Hz Voltage supply 3 phase 360 420V, 50/60HzVoltage supply single phase AC 210 240, 60Hz Page Safety Symbol Page Electrical energy Start Up Turning Machine OFF Switching Machine onTo prevent a start-up of the machine Program Data Display Measurement Display and Measurement SystemPage Manual Operation Actuate toggle switch 8 at main switch plate Setting of Measurements Backgauge Movement by HandCutting Line Indicator, Mechanical with Clamp Cutting Line Indicator, OpticalSetting the Clamping Time Clamp Pressure AdjustmentClamping and Cutting Interference into the light curtain causes Light BarrierTo continue the cutting process D2 D4 D1 D3 Continuation Light BarrierMeaning of LEDs in display unit Attaching false clamp plate Clamping with False Clamp PlateRemoving of false clamp plate Automatic Operation Functions of the menu keys Key Main menu Function Survey Program Information Key Program Directory Basic DisplaysBasic Display Program Data Program Data Key Main Menu Function SurveyContin. Basic Display Program Data Press key Basic Display Program InformationOther input modes in this display Basic Display Program Directory1575 5VACPress menu key Basic Display Main Menu Function SurveyCursor Movement in Basic Display Backgauge moves Automatic Backgauge Adjustment through Numerical KeyboardMeasurement input in inches Program data display After 1. inputinput section showsDeletion of a wrong input Input Error Value of Nom. Backgauge Position too Low/HighDeletion of a Wrong Input Moving Backgauge to a Nominal Position PositioningMake selection Program Number Possible in all 4 basic monitor displaysDisplay example According to order number Selecting a ProgramExample Numerical keyboard Continuing Selecting a ProgramOnly in Program data display Storage of MeasurementsRunning the program Setting Up a Cutting Program, ExampleTwo side trim on size DIN A3 Untrimmed size 31 x 43 cm Key inputCall program 5A Enter Correcting before storing Correction of an Input ErrorCorrecting after storing Made GO to Position Automatic ON/OFFAutomatic OFF Positioning check in automatic operationRunning a Cutting Program Example Setting a cutting program, exampleAfter cut End of information input Storing of Program InformationsPress key Program Information Storing OrderDeletion of a Step Number Deletion of One/Several Programs Deletion of Complete Memory PROStoring of Measurements According to Printed Image Inserting of Measurements into a ProgramTo set backgauge to a calculated size Overflow IndicatorCalculator Functions ConditionsAutomatic OFFSwitching the function off Using Backgauge Position of CalculationsNegative Sign Machine Functions Machine Functions and Additional Functions Menu KeysAdditional Functions Key Main Menu Key Main Menu includes the following functions Machine Function Main Menu Function SurveySelect function Language or Measuring Unit ServiceSelect Language / Measuring Unit Select Main Menu Funtion surveyKnife change Knife CompensationCalibration to compensate for knifes of different thickness Select function Select Knife compensationResting Time for Knife at BDC Adjust timeSet counter Maintenance Cut CounterSelection of Main Menu Correction of Current Position Preset FunctionsCalculate basic position Abortion of reference run Continuing Preset FunctionsSelect function Preset functions Scan Reference Positionj Possible funtions in Auxiliary modeEnd of input with key Adjustment of Display ContrastBlock Programming Possibility of edge trim preadjustingExample Variation 1, selection 1 Angular cut Setting up a Block ProgrammingCorrection of an input parameter with Block Programming Selection of an input parameter with Block ProgrammingDeletion of an input parameter with Block Programming Enter Edge trim Example Variation 1, selection Four trim cutFour trim cut Four trim cut with labels Example Variation 3, selection 3 Four trim cut with labelsBlock Programming Four-side trim with labels and trim cuts Right-hand lay side Enter trimout measurement Enter outside trimBlock Programming Menu Key Additional Functions Subsequent Storing of Additional Functions Storage of Additional Functions with Cut SizeErase Additional Function Additional function Jogging mark Operation List of Additional FunctionsEjector OFF K5C Menu Key Auxiliary Functions Sheet Size Tables Cut and RecordAfter program generation Quitt the function Subtraction Repetition UnitGraphics OFF K5D Menu Key Machine Parameters Make selection Adjustment of pre-pressure timeAdjustment of BDC time Prepressure TimeKnife Change Deposit knife in knife box!! Remove knife guard Mounting the knife Knife ChangeTighten up all knife bolts Adjustment of knife pre-tensionKnife adjustment Adjusting the knifeNormal Turn over Changing of cutting stickRemoving of cutting stick Inserting of cutting stickPage Malfunctions / Breakdowns Remedy for machine malfunctions Electrical Malfunctions/BreakdownsMachine functions possible in Auxiliary Mode Start Up Breakdown Scan Reference Point/Auxiliary ModeBreakdown Clamp stops beneath the upper dead centre Breakdown Knife bar stops beneath the upper dead centreKnife bar or clamp not in top dead centre Maintenance Basic information about servicing and maintenance work Lubrication intervals weekly Quantity liters 22,5Hrs. per day equal Cleaning of DisplayPage Fax 937/492-7280 Service Mr./MrsBaum USA