Baum Bros. Imports 26.4 manual Basic Displays, Basic Display Program Data

Page 37

5.0 Automatic Operation

Basic Displays

1.

Program Data:

key

3.

Main Menu (Function Survey):

key

2.

Program Information:

key

4.

Program Directory:

key

Basic Display: Program Data

Press key < display shows program data display:(appears automatically after start-up*)

Explanation of Program-Data-display:

6

10

1

Program head (menu pictograph, program number (P: 1A) with memory

 

 

 

 

 

 

 

 

 

 

 

 

 

segment (S: 0) designation A )

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Data section (3 step number visible on one page

 

 

 

4

 

 

3

Input section

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

4

Size display

 

 

 

 

 

 

 

2

 

 

 

 

 

 

5

Display of additional functions stored with step number

 

 

 

 

 

 

6

Status display (current machine function)

9

 

 

 

 

 

 

 

 

8

 

7

Display section Additional Function (after selection

 

 

 

 

 

 

 

7

 

3

 

 

 

8Pictographs for user prompting (possible operating functions)

9Current programming function with pictograph

10

Rolling bar (movement by cursor keys)

* If this fails, see "Malfunctions/Breakdowns, page K7 - 2"

 

 

K5A - 3

Image 37
Contents Baumcut 26.4 Programmable K5A IndexK5B Index MaintenanceK5C K5DControl Panel / Operating Elements ProgrammableExplanation of Pictographs on the Display Chapter Survey Chapter SurveyPlease pay special attention to the following information IntroductionCopyright Page Page Machine Layout Plan Dimensions in mmPlace of Installation Transport and Installation of the MachineAfter the Installation of the Machine Case of ComplaintsEnergy lead wire Power SupplyType plate Type Plates Type plateSafety Auxiliary Tools Safety Relevant Machine ElementsWorking Area of Operating Personnel Placement of the warning labels Label 1 Label 2 Label 3 Placement of the warning label DurabilitySafety Signs / Warning Signs Safety SignsSafety Precautions Technical DataPermissible Environmental and Operating Conditions Hydraulic DataVoltage supply single phase AC 200 240, 50Hz Voltage supply 3 phase 360 420V, 50/60HzVoltage supply single phase AC 210 240, 60Hz Page Safety Symbol Page Electrical energy Start Up Turning Machine OFF Switching Machine onTo prevent a start-up of the machine Program Data Display Measurement Display and Measurement SystemPage Manual Operation Cutting Line Indicator, Mechanical with Clamp Setting of Measurements Backgauge Movement by HandCutting Line Indicator, Optical Actuate toggle switch 8 at main switch plateSetting the Clamping Time Clamp Pressure AdjustmentClamping and Cutting Interference into the light curtain causes Light BarrierTo continue the cutting process D2 D4 D1 D3 Continuation Light BarrierMeaning of LEDs in display unit Attaching false clamp plate Clamping with False Clamp PlateRemoving of false clamp plate Automatic Operation Functions of the menu keys Key Main menu Function Survey Basic Display Program Data Basic DisplaysProgram Data Key Main Menu Function Survey Program Information Key Program DirectoryContin. Basic Display Program Data Press key Basic Display Program Information1575 Basic Display Program Directory5VAC Other input modes in this displayPress menu key Basic Display Main Menu Function SurveyCursor Movement in Basic Display Measurement input in inches Automatic Backgauge Adjustment through Numerical KeyboardProgram data display After 1. inputinput section shows Backgauge movesDeletion of a Wrong Input Input Error Value of Nom. Backgauge Position too Low/HighMoving Backgauge to a Nominal Position Positioning Deletion of a wrong inputMake selection Program Number Possible in all 4 basic monitor displaysDisplay example According to order number Selecting a ProgramExample Numerical keyboard Continuing Selecting a ProgramOnly in Program data display Storage of MeasurementsTwo side trim on size DIN A3 Untrimmed size 31 x 43 cm Setting Up a Cutting Program, ExampleKey input Running the programCall program 5A Enter Correcting before storing Correction of an Input ErrorCorrecting after storing Automatic OFF Automatic ON/OFFPositioning check in automatic operation Made GO to PositionRunning a Cutting Program Example Setting a cutting program, exampleAfter cut Press key Program Information Storing of Program InformationsStoring Order End of information inputDeletion of a Step Number Deletion of One/Several Programs Deletion of Complete Memory PROStoring of Measurements According to Printed Image Inserting of Measurements into a ProgramCalculator Functions Overflow IndicatorConditionsAutomatic OFF To set backgauge to a calculated sizeSwitching the function off Using Backgauge Position of CalculationsNegative Sign Machine Functions Machine Functions and Additional Functions Menu KeysAdditional Functions Key Main Menu Key Main Menu includes the following functions Machine Function Main Menu Function SurveySelect Language / Measuring Unit ServiceSelect Main Menu Funtion survey Select function Language or Measuring UnitCalibration to compensate for knifes of different thickness Knife CompensationSelect function Select Knife compensation Knife changeResting Time for Knife at BDC Adjust timeSet counter Maintenance Cut CounterSelection of Main Menu Correction of Current Position Preset FunctionsCalculate basic position Select function Preset functions Scan Reference Positionj Continuing Preset FunctionsPossible funtions in Auxiliary mode Abortion of reference runEnd of input with key Adjustment of Display ContrastBlock Programming Possibility of edge trim preadjustingExample Variation 1, selection 1 Angular cut Setting up a Block ProgrammingCorrection of an input parameter with Block Programming Selection of an input parameter with Block ProgrammingDeletion of an input parameter with Block Programming Enter Edge trim Example Variation 1, selection Four trim cutFour trim cut Four trim cut with labels Example Variation 3, selection 3 Four trim cut with labelsBlock Programming Four-side trim with labels and trim cuts Right-hand lay side Enter trimout measurement Enter outside trimBlock Programming Menu Key Additional Functions Subsequent Storing of Additional Functions Storage of Additional Functions with Cut SizeErase Additional Function Additional function Jogging mark Operation List of Additional FunctionsEjector OFF K5C Menu Key Auxiliary Functions Sheet Size Tables Cut and RecordAfter program generation Quitt the function Subtraction Repetition UnitGraphics OFF K5D Menu Key Machine Parameters Adjustment of BDC time Adjustment of pre-pressure timePrepressure Time Make selectionKnife Change Deposit knife in knife box!! Remove knife guard Mounting the knife Knife ChangeKnife adjustment Adjustment of knife pre-tensionAdjusting the knife Tighten up all knife boltsRemoving of cutting stick Changing of cutting stickInserting of cutting stick Normal Turn overPage Malfunctions / Breakdowns Remedy for machine malfunctions Electrical Malfunctions/BreakdownsMachine functions possible in Auxiliary Mode Start Up Breakdown Scan Reference Point/Auxiliary ModeBreakdown Clamp stops beneath the upper dead centre Breakdown Knife bar stops beneath the upper dead centreKnife bar or clamp not in top dead centre Maintenance Basic information about servicing and maintenance work Lubrication intervals weekly Quantity liters 22,5Hrs. per day equal Cleaning of DisplayPage Fax 937/492-7280 Service Mr./MrsBaum USA