Graco 313289s important safety instructions Flush Before Using Equipment

Page 13

 

Before Repair

11. Disengage trigger lock.

Flush Before Using Equipment

TI1950a

12.Hold a metal part of the gun firmly to a grounded metal pail with a splash guard in place. Trigger gun to flush mixed material out of line with clean solvent.

13.Shut off solvent pump on air control panel.

14.Repeat steps 11 and 12. Then continue to step 15.

15.Close solvent flush valve (AK) on mix manifold.

AK

The equipment was tested with lightweight oil, which is left in the fluid passages to protect parts. To avoid con- taminating your fluid with oil, flush the equipment with a compatible solvent before use. See Flush on page 14.

r_312359_313289_5

16.Release any residual gun pressure and engage trig- ger lock.

TI1949a

313289S

13

Image 13
Contents XM Plural-Component Sprayers313289S Contents Component Manuals in U.S. English Related ManualsManual Description Fire and Explosion Hazard Intrinsic Safety Equipment Misuse Hazard Location Category Key ModelsXM a XM B XM D XM C XM E ApprovalsIsocyanate Hazard OverviewMaterial Self-Ignition Moisture Sensitivity IsocyanatesChanging Materials Components a and BKeep Components a and B Separate Lift Using a Hoist Lift Using a ForkliftBefore Repair Location Proper Lifting of SprayerRelieve a and B Fluid Pressure Pressure Relief ProcedureRelieve Pump Fluid Pressure Flush Before Using Equipment Flush Mixed Material FlushFlush Mix Manifold Use Solvent PumpFollow Pressure Relief Procedure, Empty and Flush Entire System new sprayer or end of job ProcedureGuidelines Turn on heaters until fluid lines are clear of sol- ventR3123593132896 R3123593132897 Relieve pressure. See Pressure Relief Procedure, Cleaning ProcedureShutdown Entire System Flush Entire System new sprayer or end of job onXM Setup and Troubleshooting Guide Problem Cause Solution TroubleshootingSee Appendix a in manual Tor Power Supply Control Compo View Alarms AlarmsDiagnose Alarms Clear AlarmsAlarm Code Alarm Problem When Active Cause Solution Alarm Codes and TroubleshootingSee Pump Assembly, Pump Test Daily Check Recommended Optional User-Settable Maintenance Warnings Optional User-Settable Spray Limits Mode Control Logic Alarms Possible Alarms by ModeR2D StopAlarm Code Key LED Diagnostic InformationModule Status LED Signal Diagnosis Solution What Alert WhereReplace Air Filter Element RepairMain Air Inlet Manifold Filter Both FiltersRemove Shroud User Interface/Control BoxReplace Solenoid Module DVA DVBLoad software. See Update USB Module Soft Ware Update USB Module SoftwareReplace USB Module Load software. See Update Fluid Control Module FCM Software Update Fluid Control Module FCM SoftwareReplace Fluid Control Module FCM Upgrade Software Replace AlarmDisplay Replace Display Replace Display BatteryReplace Power Supply Module Wall Power Supply Control ComponentsReplace Front Panel Alternator Module Repair Alternator Power Supply Control ComponentsFCM USBReplace Alternator Regulator Air Controls Gauge 326 319 330 340 331 Dosing Valve Assembly Fluid Control AssemblyMix Manifold Assembly Sensors Temperature RTD SensorReplace Fluid Pressure Sensor Remove Pump Assembly Pump AssemblyRemove Displacement Pump Remove Air Motor Solvent Pump Service and RepairFluid Heaters ReplaceSimplified Electrical Schematic, XM Sprayer with Alternator Electrical SchematicsElectrical Schematics 313289S Simplified Pneumatic Schematic, XM Sprayer with Alternator313289S Detailed Electrical Schematic, XM Sprayer with AlternatorBlue Green Detailed Electrical Schematic, XM Sprayer with AlternatorXM Plural Component Sprayer with Wall Power Simplified Electrical Schematic, XM Sprayer with Wall PowerSimplified Pneumatic Schematic, XM Sprayer with Wall Power Manual With Wall PowerDetailed Electrical Schematic, XM Sprayer with Wall Power Box Wiring SchematicsFluid HeatersHopper Heaters Junction Box Wiring Schematics 313289S XM Plural-Component Sprayers PartsXM1, XM2 XM3, XM4XM5, XM6 XMB and XMEXM7, XM8 Models 113 114 120 121 122 135 137 115 Common Parts Fluid Control Assembly PartsPart Description Qty See Air Controls Module Parts,XM1 and XM2 Models Parts Varying by ModelXM1 and XM2 Models XM Plural-Component Sprayer Models Part Description XM3 and XM4 ModelsXM3 and XM4 Models XM5 and XM6 Models Adapter XM7 and XM8 Models XM7 and XM8 Models Control Box 255771 Parts Air Power and Electric Power VersionsPart Description LabelMODULE, USB BaseAlternator Assembly Control Box Power Supply OptionsWall Power Supply Assembly Cable Connections Wall Power Supply AssemblyAdapter Air Controls Module 255761 PartsRegulator CouplingJunction Box 256540 Parts Switch 25ACircuit Breaker 25A Circuit Breaker 10ASENSOR, RTD Fluid Control Assembly PartsSwivel Air Inlet Manifold 255762 PartsCAP Plug Turbine Alternator Module 255728 PartsRepair and Spare Parts Reference Part Description Qty Part of AssemblyAccessories and Kits Desiccant Dryer Kit Electric Heated Hose Power Supply KitShutoff/Check Valve Kit Caster KitSystem Dimensions without Hoppers DimensionsTwo 20-Gallon Hoppers Side Mounted System Dimensions with HoppersTwo 20-Gallon Hoppers Rear Mounted Two 7-Gallon Hoppers One 20-Gallon Hopper and One 7-Gallon HopperPTFE, Uhmwpe Technical DataGraco Information Graco Standard Warranty