Graco 313289s important safety instructions Optional User-Settable Maintenance Warnings

Page 27

 

 

 

 

Alarms

 

 

 

 

 

Alarm

 

 

 

 

Code

Alarm Problem

When Active

Cause

Solution

 

 

 

 

 

 

 

 

 

 

V1M

Voltage low control

Always

Voltage dropping below 9 Vdc

Change air filter in control filter

 

 

 

from power supply.

regulator. See Replace Air Fil-

 

 

 

 

ter Element, page 31.

 

 

 

 

 

 

 

 

 

Check the pressure setting is

 

 

 

 

18 psi (0.12 MPa, 1.24 bar) on

 

 

 

 

turbine air regulator.

 

 

 

 

 

 

 

 

 

Check voltage on information

 

 

 

 

screen.

 

 

 

 

 

 

 

 

Turbine not spinning with air on.

Replace air turbine cartridge.

 

 

 

 

See Alternator Power Supply

 

 

 

 

Control Components, page

 

 

 

 

38.

 

 

 

 

 

N6C

Display has no signal.

Always

No display communication sig-

Check cable connections.

 

 

 

nal.

Replace display.

 

 

 

 

 

 

 

 

Machine powered down in

Press stop button before turning

 

 

 

spray mode.

off power.

 

 

 

 

 

DLA

A air motor reed switch signal

Always

Reed switch does not see the

Replace air motor reed switch

 

missing advisory.

 

air motor magnet.

magnet.

 

 

 

 

 

 

 

 

Reed switches are bad.

Replace air motor reed switch.

 

 

 

 

Prevent air motor icing. See

 

 

 

Air motor is icing up.

 

 

 

advisory P9A and P9B.

 

 

 

 

 

 

 

 

 

DLB

B air motor reed switch signal

Always

Reed switch does not see the

Replace air motor reed switch

 

missing advisory.

 

air motor magnet.

magnet.

 

 

 

 

 

 

 

 

Reed switches are bad.

Replace air motor reed switch.

 

 

 

 

Prevent air motor icing. See

 

 

 

Air motor is icing up.

 

 

 

advisory P9A and P9B.

 

 

 

 

 

 

 

 

 

DMA

A air motor linear sensor

Always

System ran out of fluid.

Add fluid to the system.

 

jump advisory.

 

 

 

 

 

Linear sensor is bad.

Replace linear sensor.

 

 

 

 

 

 

 

 

DMB

B air motor linear sensor

Always

System ran out of fluid.

Add fluid to the system.

 

jump advisory.

 

 

 

 

 

Linear sensor is bad.

Replace linear sensor.

 

 

 

 

 

 

 

 

 

Optional User-Settable Maintenance Warnings

 

MAA

Maintain pump

Always, if enabled

Pump usage exceeds user-set

Service pump. See Pump

MAB

 

 

limit. Maintenance due.

Assembly, page 44.

 

 

 

 

 

MEA

Maintain dosing valve

Always, if enabled

Dosing valve usage exceeds

Service dosing valve. See Dos-

MEB

 

 

user-set limit. Maintenance

ing Valve Assembly, page 42.

 

 

 

due.

 

 

 

 

 

 

MG0

Maintain air filter

Always, if enabled

Air filter exceeds user-set limit.

Service main air filter and con-

 

 

 

Maintenance due.

trol filter regulator. See Replace

 

 

 

 

Air Filter Element, page 31.

 

 

 

 

 

P5A

Pressure exceeded alarm

Always, if enabled

Pressure exceeded high or low

Adjust pump pressure regulator,

P5B

limits

 

alarm limits for more than 15

change tips, or adjust target set

 

 

 

seconds.

point.

 

 

 

 

 

313289S

27

Image 27
Contents XM Plural-Component Sprayers313289S Contents Related Manuals Component Manuals in U.S. EnglishManual Description Fire and Explosion Hazard Intrinsic Safety Equipment Misuse Hazard Location Category Key ModelsXM a XM B XM D XM C XM E ApprovalsMoisture Sensitivity Isocyanates OverviewIsocyanate Hazard Material Self-IgnitionComponents a and B Changing MaterialsKeep Components a and B Separate Location Proper Lifting of Sprayer Lift Using a ForkliftLift Using a Hoist Before RepairPressure Relief Procedure Relieve a and B Fluid PressureRelieve Pump Fluid Pressure Flush Before Using Equipment Use Solvent Pump FlushFlush Mixed Material Flush Mix ManifoldFollow Pressure Relief Procedure, Turn on heaters until fluid lines are clear of sol- vent ProcedureEmpty and Flush Entire System new sprayer or end of job GuidelinesR3123593132896 R3123593132897 Flush Entire System new sprayer or end of job on Cleaning ProcedureRelieve pressure. See Pressure Relief Procedure, Shutdown Entire SystemXM Setup and Troubleshooting Guide Problem Cause Solution TroubleshootingSee Appendix a in manual Tor Power Supply Control Compo Clear Alarms AlarmsView Alarms Diagnose Alarms Alarm Code Alarm Problem When Active Cause Solution Alarm Codes and TroubleshootingSee Pump Assembly, Pump Test Daily Check Recommended Optional User-Settable Maintenance Warnings Optional User-Settable Spray Limits Stop Possible Alarms by ModeMode Control Logic Alarms R2DWhat Alert Where LED Diagnostic InformationAlarm Code Key Module Status LED Signal Diagnosis SolutionBoth Filters RepairReplace Air Filter Element Main Air Inlet Manifold FilterDVA DVB User Interface/Control BoxRemove Shroud Replace Solenoid ModuleUpdate USB Module Software Load software. See Update USB Module Soft WareReplace USB Module Update Fluid Control Module FCM Software Load software. See Update Fluid Control Module FCM SoftwareReplace Fluid Control Module FCM Replace Alarm Upgrade SoftwareDisplay Replace Display Replace Display BatteryWall Power Supply Control Components Replace Power Supply ModuleReplace Front Panel USB Alternator Power Supply Control ComponentsAlternator Module Repair FCMReplace Alternator Regulator Air Controls Gauge 326 319 330 340 331 Fluid Control Assembly Dosing Valve AssemblyMix Manifold Assembly Temperature RTD Sensor SensorsReplace Fluid Pressure Sensor Pump Assembly Remove Pump AssemblyRemove Displacement Pump Remove Air Motor Replace Service and RepairSolvent Pump Fluid HeatersSimplified Electrical Schematic, XM Sprayer with Alternator Electrical SchematicsElectrical Schematics 313289S Simplified Pneumatic Schematic, XM Sprayer with Alternator313289S Detailed Electrical Schematic, XM Sprayer with AlternatorBlue Green Detailed Electrical Schematic, XM Sprayer with AlternatorXM Plural Component Sprayer with Wall Power Simplified Electrical Schematic, XM Sprayer with Wall PowerSimplified Pneumatic Schematic, XM Sprayer with Wall Power Manual With Wall PowerDetailed Electrical Schematic, XM Sprayer with Wall Power Heaters Wiring SchematicsBox FluidHopper Heaters Junction Box Wiring Schematics 313289S XM3, XM4 PartsXM Plural-Component Sprayers XM1, XM2XMB and XME XM5, XM6XM7, XM8 Models 113 114 120 121 122 135 137 115 See Air Controls Module Parts, Fluid Control Assembly PartsCommon Parts Part Description QtyXM1 and XM2 Models Parts Varying by ModelXM1 and XM2 Models XM Plural-Component Sprayer Models Part Description XM3 and XM4 ModelsXM3 and XM4 Models XM5 and XM6 Models Adapter XM7 and XM8 Models XM7 and XM8 Models Label Air Power and Electric Power VersionsControl Box 255771 Parts Part DescriptionMODULE, USB BaseAlternator Assembly Control Box Power Supply OptionsWall Power Supply Assembly Cable Connections Wall Power Supply AssemblyCoupling Air Controls Module 255761 PartsAdapter RegulatorCircuit Breaker 10A Switch 25AJunction Box 256540 Parts Circuit Breaker 25ASENSOR, RTD Fluid Control Assembly PartsAir Inlet Manifold 255762 Parts SwivelCAP Plug Turbine Alternator Module 255728 PartsRepair and Spare Parts Reference Part Description Qty Part of AssemblyAccessories and Kits Caster Kit Electric Heated Hose Power Supply KitDesiccant Dryer Kit Shutoff/Check Valve KitSystem Dimensions without Hoppers DimensionsSystem Dimensions with Hoppers Two 20-Gallon Hoppers Side MountedTwo 20-Gallon Hoppers Rear Mounted Two 7-Gallon Hoppers One 20-Gallon Hopper and One 7-Gallon HopperPTFE, Uhmwpe Technical DataGraco Information Graco Standard Warranty