| Alarms |
|
|
|
|
|
Alarm |
|
|
|
|
Code | Alarm Problem | When Active | Cause | Solution |
|
|
|
|
|
|
|
|
|
|
V1M | Voltage low control | Always | Voltage dropping below 9 Vdc | Change air filter in control filter |
|
|
| from power supply. | regulator. See Replace Air Fil- |
|
|
|
| ter Element, page 31. |
|
|
|
|
|
|
|
|
| Check the pressure setting is |
|
|
|
| 18 psi (0.12 MPa, 1.24 bar) on |
|
|
|
| turbine air regulator. |
|
|
|
|
|
|
|
|
| Check voltage on information |
|
|
|
| screen. |
|
|
|
|
|
|
|
| Turbine not spinning with air on. | Replace air turbine cartridge. |
|
|
|
| See Alternator Power Supply |
|
|
|
| Control Components, page |
|
|
|
| 38. |
|
|
|
|
|
N6C | Display has no signal. | Always | No display communication sig- | Check cable connections. |
|
|
| nal. | Replace display. |
|
|
|
|
|
|
|
| Machine powered down in | Press stop button before turning |
|
|
| spray mode. | off power. |
|
|
|
|
|
DLA | A air motor reed switch signal | Always | Reed switch does not see the | Replace air motor reed switch |
| missing advisory. |
| air motor magnet. | magnet. |
|
|
|
|
|
|
|
| Reed switches are bad. | Replace air motor reed switch. |
|
|
|
| Prevent air motor icing. See |
|
|
| Air motor is icing up. | |
|
|
| advisory P9A and P9B. | |
|
|
|
| |
|
|
|
|
|
DLB | B air motor reed switch signal | Always | Reed switch does not see the | Replace air motor reed switch |
| missing advisory. |
| air motor magnet. | magnet. |
|
|
|
|
|
|
|
| Reed switches are bad. | Replace air motor reed switch. |
|
|
|
| Prevent air motor icing. See |
|
|
| Air motor is icing up. | |
|
|
| advisory P9A and P9B. | |
|
|
|
| |
|
|
|
|
|
DMA | A air motor linear sensor | Always | System ran out of fluid. | Add fluid to the system. |
| jump advisory. |
|
|
|
|
| Linear sensor is bad. | Replace linear sensor. | |
|
|
| ||
|
|
|
|
|
DMB | B air motor linear sensor | Always | System ran out of fluid. | Add fluid to the system. |
| jump advisory. |
|
|
|
|
| Linear sensor is bad. | Replace linear sensor. | |
|
|
| ||
|
|
|
|
|
| Optional |
| ||
MAA | Maintain pump | Always, if enabled | Pump usage exceeds | Service pump. See Pump |
MAB |
|
| limit. Maintenance due. | Assembly, page 44. |
|
|
|
|
|
MEA | Maintain dosing valve | Always, if enabled | Dosing valve usage exceeds | Service dosing valve. See Dos- |
MEB |
|
| ing Valve Assembly, page 42. | |
|
|
| due. |
|
|
|
|
|
|
MG0 | Maintain air filter | Always, if enabled | Air filter exceeds | Service main air filter and con- |
|
|
| Maintenance due. | trol filter regulator. See Replace |
|
|
|
| Air Filter Element, page 31. |
|
|
|
|
|
P5A | Pressure exceeded alarm | Always, if enabled | Pressure exceeded high or low | Adjust pump pressure regulator, |
P5B | limits |
| alarm limits for more than 15 | change tips, or adjust target set |
|
|
| seconds. | point. |
|
|
|
|
|