| Troubleshooting | |
|
|
|
| |
TYPE OF PROBLEM | WHAT TO CHECK |
| HOW TO CHECK | |
|
|
|
| |
|
|
|
| |
Sprayer does not run at all | Check transducer or transducer | 1. | Set sprayer to OFF and disconnect power to sprayer. | |
| connections (control board is not |
|
| |
Digital display shows E=03 | 2. | Check transducer and connections to control board. | ||
detecting a pressure signal). | ||||
| ||||
|
| 3. | Disconnect transducer from control board socket. | |
|
|
| Check to see if transducer and control board | |
|
|
| contacts are clean and secure. | |
|
|
|
| |
Control board status light blinks |
| 4. | Reconnect transducer to control board socket. | |
3 times repeatedly |
| |||
|
| Connect power, set sprayer ON and control knob | ||
|
|
| ||
|
|
| to 1/2 turn clockwise. If sprayer does not run, | |
|
|
| set sprayer to OFF and go to next step. | |
|
| 5. | Connect a confirmed working transducer to control | |
|
|
| board socket. | |
|
| 6. | Set sprayer ON and control knob to 1/2 turn | |
|
|
| clockwise. If sprayer runs, install new transducer. | |
|
|
| Replace control board if sprayer does not run. | |
|
| 7. | Check transducer resistance with ohmmeter (less | |
|
|
| than 9k ohm between red and black wires and | |
|
|
| ohm between green and yellow wires). | |
|
|
|
|
14 | 311365G |