Graco Inc ti13461a, 311365G, ti13460a Sprayer does not run at all Check transducer or transducer

Page 14

 

 

 

Troubleshooting

 

 

 

 

TYPE OF PROBLEM

WHAT TO CHECK

 

HOW TO CHECK

 

 

 

 

 

 

 

 

Sprayer does not run at all

Check transducer or transducer

1.

Set sprayer to OFF and disconnect power to sprayer.

 

connections (control board is not

 

 

Digital display shows E=03

2.

Check transducer and connections to control board.

detecting a pressure signal).

 

 

 

3.

Disconnect transducer from control board socket.

 

 

 

Check to see if transducer and control board

 

 

 

contacts are clean and secure.

 

 

 

 

Control board status light blinks

 

4.

Reconnect transducer to control board socket.

3 times repeatedly

 

 

 

Connect power, set sprayer ON and control knob

 

 

 

 

 

 

to 1/2 turn clockwise. If sprayer does not run,

 

 

 

set sprayer to OFF and go to next step.

 

 

5.

Connect a confirmed working transducer to control

 

 

 

board socket.

 

 

6.

Set sprayer ON and control knob to 1/2 turn

 

 

 

clockwise. If sprayer runs, install new transducer.

 

 

 

Replace control board if sprayer does not run.

 

 

7.

Check transducer resistance with ohmmeter (less

 

 

 

than 9k ohm between red and black wires and 3-6k

 

 

 

ohm between green and yellow wires).

 

 

 

 

14

311365G

Image 14
Contents Mark Important Safety InstructionsKorean patent10-0579681 Table of Contents Models Vac Model Type Lo-Boy Hi-Boy 240 Grounding Instructions GroundingFire and Explosion Hazard Skin Injection HazardPressurized Aluminum Parts Hazard Equipment Misuse HazardElectric Shock Hazard Moving Parts HazardComponent Identification and Function Pressure Relief Procedure General Repair InformationGrounding What to Check What to do Type of Problem Mechanical/Fluid FlowTroubleshooting Type of Problem What to Check HOW to Check ElectricalSprayer does not run at all Check transducer or transducer Step 100k ohm Reconnect thermal device connector to control Sprayer Will Not Shut Off YESSprayer Will Not Run See following page for stepsRemoval InstallationPressure Control Board 100 120 Vac North American Japan/Taiwan Vac Motor Control Board Vac Filter Board 240 VacVac U.K. Motor Control Board Vac U.K. Filter Board Vac U.K Pressure Adjust Potentiometer Pressure Control Transducer Install control box 61 and control panel 68 with four screws Drive and Bearing Housing Replacement DisassemblyAssembly158 108 Removal Motor ReplacementInstallation 158 90a 612 906 Displacement Pump Replacement for 695/795 Ti7169a Displacement Pump Replacement 1095/1595/Mark Open pump door Tighten latch and rotate latch lock into locked position Wiring Diagram ON/OFF Japan/Taiwan Japan/Taiwan Models Graco Standard Warranty For Graco Canada Customers