Graco Inc ti13461a, 311365G, ti13460a General Repair Information, Pressure Relief Procedure

Page 9

General Repair Information

General Repair Information

Pressure Relief Procedure

SKIN INJECTION HAZARD

System pressure must be manually relieved to prevent system from starting or spraying accidentally. Fluid under high pressure can be injected through skin and cause serious injury. To reduce risk of injury from injection, splashing fluid, or moving parts, follow Pressure Relief Procedure whenever you:

are instructed to relieve pressure

stop spraying

check or service any system equipment

install or clean spray tip

1.Turn pressure control knob to zero.

2.Turn ON/OFF switch to OFF.

3.Unplug power supply cord.

4.Hold metal part of gun firmly to grounded metal pail. Trigger gun to relieve pressure.

5.Lock gun safety latch.

6.Open prime valve. Leave prime valve open until ready to spray again.

If suspected that spray tip or hose is completely clogged, or that pressure has not been fully relieved after following steps above, VERY SLOWLY loosen tip guard retaining nut or hose end coupling to relieve pressure gradually, then loosen completely. Then clear tip or hose obstruction.

CAUTION

To reduce risk of pressure control malfunction:

Use needle-nose pliers to disconnect wire. Never pull on wire, pull on connector.

Mate wire connectors properly. Center flat blade of insulated male connector in female connector.

Route wires carefully to avoid interference with other connections of pressure control. Do not pinch wires between cover and control box.

1.Keep all screws, nuts, washers, gaskets, and electrical fittings removed during repair procedures. These parts are not normally provided with replacement assemblies.

ELECTRIC SHOCK HAZARD

MOVING PARTS HAZARD

HOT SURFACE HAZARD

To reduce risk of serious injury, including electric shock, do not touch moving or electrical parts with fingers or tools while testing repair. Shut off and unplug sprayer when inspection is complete. Install all covers, guards, gaskets, screws, washers and shroud before operating sprayer.

2.Test repair after problem is corrected.

3.If sprayer does not operate properly, review repair procedure to verify procedure was done correctly. If necessary, see Troubleshooting, page 11, for other possible solutions.

311365G

9

Image 9
Contents Important Safety Instructions Korean patent10-0579681Mark Table of Contents Models Vac Model Type Lo-Boy Hi-Boy 240 Grounding Grounding InstructionsSkin Injection Hazard Fire and Explosion HazardElectric Shock Hazard Equipment Misuse HazardPressurized Aluminum Parts Hazard Moving Parts HazardComponent Identification and Function General Repair Information Pressure Relief ProcedureGrounding Mechanical/Fluid Flow What to Check What to do Type of ProblemTroubleshooting Electrical Type of Problem What to Check HOW to CheckSprayer does not run at all Check transducer or transducer Step 100k ohm Reconnect thermal device connector to control YES Sprayer Will Not Shut OffSee following page for steps Sprayer Will Not RunInstallation Pressure Control BoardRemoval 100 120 Vac North American Japan/Taiwan Vac Motor Control Board 240 Vac Vac Filter BoardVac U.K. Motor Control Board Vac U.K. Filter Board Vac U.K Pressure Adjust Potentiometer Pressure Control Transducer Install control box 61 and control panel 68 with four screws DisassemblyAssembly Drive and Bearing Housing Replacement158 108 Motor Replacement InstallationRemoval 158 90a 612 906 Displacement Pump Replacement for 695/795 Ti7169a Displacement Pump Replacement 1095/1595/Mark Open pump door Tighten latch and rotate latch lock into locked position Wiring Diagram ON/OFF Japan/Taiwan Japan/Taiwan Models For Graco Canada Customers Graco Standard Warranty