Graco Inc ti13459a, 311365G, ti13460a, ti13450a Reconnect thermal device connector to control

Page 17

 

 

 

 

 

 

 

Troubleshooting

 

 

 

 

 

 

 

 

TYPE OF PROBLEM

WHAT TO CHECK

 

 

HOW TO CHECK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sprayer does not run at all

Allow sprayer to cool. If sprayer runs

NOTE: Motor must be cooled down for the test.

 

when cool, correct cause of

 

 

 

 

 

 

 

Digital display shows E=06

1.

Check thermal device connector (yellow wires)

overheating. Keep sprayer in cooler

 

 

location with good ventilation. Make

 

at control board.

 

 

 

 

 

 

 

 

 

 

 

 

sure motor air intake is not blocked.

2. Disconnect thermal device connector from control

 

If sprayer still does not run, follow

 

board socket. Make sure contacts are clean and

Control board status light blinks

Step 1.

 

secure.

 

 

 

6 times repeatedly

 

3. Measure resistance of the thermal device. If reading

 

 

 

 

 

is not correct, replace motor.

 

 

 

Check Motor Thermal Switch: Unplug thermal

 

 

 

wires. Set meter to ohms. Meter should read the

 

 

 

proper resistance for each model (see table below).

 

 

 

 

100k ohm

 

 

 

 

 

 

-

 

 

 

 

 

 

 

 

ti13140a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Resistance Table:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

695

 

0 ohms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

795

 

2k ohms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1095

 

3.9k ohms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MARK V

 

3.9k ohms

 

 

 

 

 

 

 

 

 

 

4. Reconnect thermal device connector to control

 

 

 

board socket. Connect power, turn sprayer ON and

 

 

 

control knob 1/2 turn clockwise. If sprayer does not

 

 

 

run, replace control board.

 

 

 

 

 

 

 

 

 

Sprayer does not run at all

Check the connections. Control

1.

Turn power OFF.

 

 

 

 

is not receiving a motor position

 

 

 

 

 

 

 

Digital display shows E=09

2. Disconnect motor position sensor and inspect for

sensor signal

 

 

 

damage at connectors.

 

 

 

 

 

3.

Reconnect sensor.

 

 

 

 

 

4. Turn power ON. If error continues, replace motor.

Control board status light blinks

 

 

 

 

 

 

 

 

 

9 times repeatedly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sprayer does not run at all

Check to see if control board is over

1.

Make sure motor air intake is not blocked.

 

heating.

 

 

 

 

 

 

 

Digital display shows E=10

2. Make sure fan has not failed.

 

 

 

 

 

3. Make sure control board is properly connected

 

 

 

to back plate and that conductive thermal paste

 

 

 

is used on power components.

Control board status light blinks

 

 

 

4.

Replace control board.

10 times repeatedly

 

 

 

 

 

 

 

 

 

 

 

5.

Replace motor.

 

 

 

 

 

 

 

 

 

 

 

 

311365G

17

Image 17
Contents Mark Important Safety InstructionsKorean patent10-0579681 Table of Contents Models Vac Model Type Lo-Boy Hi-Boy 240 Grounding Grounding InstructionsSkin Injection Hazard Fire and Explosion HazardElectric Shock Hazard Equipment Misuse HazardPressurized Aluminum Parts Hazard Moving Parts HazardComponent Identification and Function General Repair Information Pressure Relief ProcedureGrounding Mechanical/Fluid Flow What to Check What to do Type of ProblemTroubleshooting Electrical Type of Problem What to Check HOW to CheckSprayer does not run at all Check transducer or transducer Step 100k ohm Reconnect thermal device connector to control YES Sprayer Will Not Shut OffSee following page for steps Sprayer Will Not RunRemoval InstallationPressure Control Board 100 120 Vac North American Japan/Taiwan Vac Motor Control Board 240 Vac Vac Filter BoardVac U.K. Motor Control Board Vac U.K. Filter Board Vac U.K Pressure Adjust Potentiometer Pressure Control Transducer Install control box 61 and control panel 68 with four screws DisassemblyAssembly Drive and Bearing Housing Replacement158 108 Removal Motor ReplacementInstallation 158 90a 612 906 Displacement Pump Replacement for 695/795 Ti7169a Displacement Pump Replacement 1095/1595/Mark Open pump door Tighten latch and rotate latch lock into locked position Wiring Diagram ON/OFF Japan/Taiwan Japan/Taiwan Models For Graco Canada Customers Graco Standard Warranty