Installation

WARNING

If pump pin works loose, parts could break off due to force of pumping action. Parts could project through the air and result in serious injury or property damage.

CAUTION

If the pump jam nut loosens during operation, the threads of the drive housing will be damaged.

1.Extend pump piston rod 1.5 in. Apply grease to top of pump rod at (A) or inside connecting rod.

Displacement Pump Replacement for 695/795

2.Install pump pin (44). Verify retaining spring

(43)is in groove of connecting rod (85).

3.Push pump up until pump threads engage.

4.Screw in pump until threads are flush with drive housing opening. Align pump outlet to back.

5.Install washers, o-rings and suction tube

(76)and hose (94).

6.Screw jam nut (56) up onto pump until nut stops. Tighten jam nut by hand, then tap 1/8 to 1/4 turn with a 20 oz (maximum) hammer to approximately 75± 5 ft-lb (102 N•m).

7.Install pump rod shield (108) with screw

8.Fill packing nut with Graco TSL until fluid flows onto top of seal.

1.5 in.

A

ti7169a

ti7171a

311365G

35

Image 35
Contents Mark Important Safety InstructionsKorean patent10-0579681 Table of Contents Models Vac Model Type Lo-Boy Hi-Boy 240 Grounding Grounding InstructionsSkin Injection Hazard Fire and Explosion HazardMoving Parts Hazard Equipment Misuse HazardElectric Shock Hazard Pressurized Aluminum Parts HazardComponent Identification and Function General Repair Information Pressure Relief ProcedureGrounding Mechanical/Fluid Flow What to Check What to do Type of ProblemTroubleshooting Electrical Type of Problem What to Check HOW to CheckSprayer does not run at all Check transducer or transducer Step 100k ohm Reconnect thermal device connector to control YES Sprayer Will Not Shut OffSee following page for steps Sprayer Will Not RunRemoval InstallationPressure Control Board 100 120 Vac North American Japan/Taiwan Vac Motor Control Board 240 Vac Vac Filter BoardVac U.K. Motor Control Board Vac U.K. Filter Board Vac U.K Pressure Adjust Potentiometer Pressure Control Transducer Install control box 61 and control panel 68 with four screws DisassemblyAssembly Drive and Bearing Housing Replacement158 108 Removal Motor ReplacementInstallation 158 90a 612 906 Displacement Pump Replacement for 695/795 Ti7169a Displacement Pump Replacement 1095/1595/Mark Open pump door Tighten latch and rotate latch lock into locked position Wiring Diagram ON/OFF Japan/Taiwan Japan/Taiwan Models For Graco Canada Customers Graco Standard Warranty