Pressure Control Board
240 Vac Filter Board
Installation
Relieve pressure; page 9.
Removal
1.Remove four screws (38) and cover (96).
2.Disconnect display connector (A) from motor control board (52).
3.Remove bottom two screws (39). disconnect potentiometer connector (C) from motor control board (52). Disconnect power cord connectors (D) and filter board connectors (J) from ON/OFF switch (33) and remove control panel (68).
4.Disconnect WatchDog switch connector (X) from motor control board.
5.Disconnect motor control board power connectors (K) from filter board (146).
6.Remove four screws (163) from filter board (146).
1.Install filter board (146) with four screws (163).
2.Connect motor control board power connectors (K) to filter board (146).
3.Connect filter board power connectors (J) to top two terminals of ON/OFF switch (33) and power cord connectors (D) to bottom two terminals of ON/OFF switch.
4.Connect potentiometer connector (C) to motor control board (52).
5.Connect WatchDog switch (X) to motor control board.
6.Install control panel (68) with two screws (39).
7.Connect display connector (A) to motor control board (52).
8.Install cover (96) with four screws (38).
240 Vac
5
52
26
52
146
|
|
| 61 K | C |
|
| A 163 |
| |
|
|
|
| |
|
|
|
| A |
96 |
|
|
|
|
38 | J | A | A |
|
|
| E | ||
| 33 |
|
| |
|
|
|
| |
39 |
|
|
|
|
|
|
|
| E 80 |
39 |
|
| C | 20 |
|
|
| 82 |
|
68 | 67 |
| |
82 |
|
34 |
|
115 |
|
X
ti12995a
311365G | 23 |