Graco Inc ti13450a, 311365G, ti13460a Electrical, Type of Problem What to Check HOW to Check

Page 13

Troubleshooting

Electrical

Symptom: Sprayer does not run or stops running.

Relieve pressure; page 9.

Plug sprayer into correct voltage, grounded outlet

Set power switch OFF for 30 seconds and then ON again. This ensures sprayer is in normal run mode.

Turn pressure control knob clockwise 1/2 turn

View digital display

To avoid electrical shock or moving parts hazards when covers are removed for troubleshooting, wait 30 seconds after unplugging power cord for stored electricity to dissi- pate. Keep clear of electrical and moving parts during troubleshooting procedures.

If no digital display is available, use control board status light to troubleshoot prob- lems: Turn ON/OFF switch OFF, remove control cover and then turn power back ON. Observe status light. Blinking LED to- tal count equals digital error code i.e., two blinks equals E=02.

TYPE OF PROBLEM

WHAT TO CHECK

 

HOW TO CHECK

 

 

 

 

 

 

 

 

Sprayer does not run at all

See flow chart, page 19.

 

 

 

 

 

 

Digital display is blank

 

 

 

 

 

 

 

Control board status light never

 

 

 

lights

 

 

 

 

 

 

 

Sprayer does not run at all

Check transducer or transducer

1.

Make sure there is no pressure in the system (see

 

connections

 

Pressure Relief, page 9). Check fluid path for clogs,

Digital display shows E=02

 

 

 

such as clogged filter.

 

 

 

 

 

2. Use airless paint spray hose with no metal braid

 

 

 

1/4 in. x 50 ft minimum. Smaller hose or metal braid

 

 

 

hose may result in high-pressure spikes.

 

 

3.

Set sprayer to OFF and disconnect power to sprayer.

Control board status light blinks

 

 

 

 

2 times repeatedly

 

4.

Check transducer and connections to control board.

 

 

5. Disconnect transducer from control board socket.

 

 

 

Check that transducer and control board contacts

 

 

 

are clean and secure.

 

 

6. Reconnect transducer to control board socket.

 

 

 

Connect power, set sprayer ON and control knob

 

 

 

1/2 turn clockwise. If sprayer does not run properly,

 

 

 

set sprayer to OFF and go to next step.

 

 

7. Install new transducer. Connect power, set sprayer

 

 

 

ON and control knob 1/2 turn clockwise. Replace

 

 

 

control board if sprayer does not run properly.

 

 

 

 

311365G

13

Image 13
Contents Korean patent10-0579681 Important Safety InstructionsMark Table of Contents Models Vac Model Type Lo-Boy Hi-Boy 240 Grounding Grounding InstructionsSkin Injection Hazard Fire and Explosion HazardElectric Shock Hazard Equipment Misuse HazardPressurized Aluminum Parts Hazard Moving Parts HazardComponent Identification and Function General Repair Information Pressure Relief ProcedureGrounding Mechanical/Fluid Flow What to Check What to do Type of ProblemTroubleshooting Electrical Type of Problem What to Check HOW to CheckSprayer does not run at all Check transducer or transducer Step 100k ohm Reconnect thermal device connector to control YES Sprayer Will Not Shut OffSee following page for steps Sprayer Will Not RunPressure Control Board InstallationRemoval 100 120 Vac North American Japan/Taiwan Vac Motor Control Board 240 Vac Vac Filter BoardVac U.K. Motor Control Board Vac U.K. Filter Board Vac U.K Pressure Adjust Potentiometer Pressure Control Transducer Install control box 61 and control panel 68 with four screws DisassemblyAssembly Drive and Bearing Housing Replacement158 108 Installation Motor ReplacementRemoval 158 90a 612 906 Displacement Pump Replacement for 695/795 Ti7169a Displacement Pump Replacement 1095/1595/Mark Open pump door Tighten latch and rotate latch lock into locked position Wiring Diagram ON/OFF Japan/Taiwan Japan/Taiwan Models For Graco Canada Customers Graco Standard Warranty