Graco Inc 311365G, ti13460a, ti13459a, ti13450a, ti13461a Vac U.K. Filter Board

Page 25

Pressure Control Board

110 Vac U.K. Filter Board

Removal

Relieve pressure; page 9.

Wait 5 minutes before servicing.

1.Remove four screws (38) and cover (96).

2.Disconnect display connector (A) from motor control board (52).

3.Remove bottom two screws (39). Disconnect potentiometer connector (C) from motor control board (52). Disconnect filter board connector (J) and power cord connector (D) from ON/OFF switch (33). Remove control panel (68).

4.Disconnect motor board control power connectors (K) from filter board (146). Disconnect filter connector (L) from power cord connector (L).

5.Remove four screws (163) from filter board (146).

Installation

1.Connect motor control board power connectors (K) to filter board (146). Connect filter connector (L) to power cord connector (L).

2.Install filter board (146) with four screws (163).

3.Connect filter board power connector (J) and power cord connector (D) to ON/OFF switch (33).

4.Connect potentiometer connector (C) to motor control board (52).

5.Install control panel (68) with two screws (39).

6.Connect display connector (A) to motor control board (52).

7.Install cover (96) with four screws (38).

311365G

25

Image 25
Contents Korean patent10-0579681 Important Safety InstructionsMark Table of Contents Models Vac Model Type Lo-Boy Hi-Boy 240 Grounding Grounding InstructionsSkin Injection Hazard Fire and Explosion HazardElectric Shock Hazard Equipment Misuse HazardPressurized Aluminum Parts Hazard Moving Parts HazardComponent Identification and Function General Repair Information Pressure Relief ProcedureGrounding Mechanical/Fluid Flow What to Check What to do Type of ProblemTroubleshooting Electrical Type of Problem What to Check HOW to CheckSprayer does not run at all Check transducer or transducer Step 100k ohm Reconnect thermal device connector to control YES Sprayer Will Not Shut OffSee following page for steps Sprayer Will Not RunPressure Control Board InstallationRemoval 100 120 Vac North American Japan/Taiwan Vac Motor Control Board 240 Vac Vac Filter BoardVac U.K. Motor Control Board Vac U.K. Filter Board Vac U.K Pressure Adjust Potentiometer Pressure Control Transducer Install control box 61 and control panel 68 with four screws DisassemblyAssembly Drive and Bearing Housing Replacement158 108 Installation Motor ReplacementRemoval 158 90a 612 906 Displacement Pump Replacement for 695/795 Ti7169a Displacement Pump Replacement 1095/1595/Mark Open pump door Tighten latch and rotate latch lock into locked position Wiring Diagram ON/OFF Japan/Taiwan Japan/Taiwan Models For Graco Canada Customers Graco Standard Warranty