Graco Inc 311365G, ti13460a, ti13459a, ti13450a, ti13461a important safety instructions Step

Page 15

 

 

 

Troubleshooting

 

 

 

 

TYPE OF PROBLEM

WHAT TO CHECK

 

HOW TO CHECK

 

 

 

 

 

 

Sprayer does not run at all

Control is commanding motor to run

1. Remove pump and try to run sprayer. If motor runs,

 

but motor shaft does not rotate.

 

check for locked or frozen pump or drive train.

Digital display shows E=05

 

Possibly locked rotor condition, an

 

If sprayer does not run, continue to step 2.

 

 

 

open connection exists between

2.

Set sprayer to OFF and disconnect power to sprayer.

 

motor and control, there is a

 

problem with motor or control board,

3.

Disconnect motor connector(s) from control board

 

or motor amp draw is excessive.

 

 

socket(s). Check that motor connector and control

 

 

 

Control board status light blinks

 

 

 

 

board contacts are clean and secure. If contacts

5 times repeatedly

 

 

 

 

are clean and secure, continue to step 4.

 

 

 

 

 

4. Set sprayer to OFF and spin motor fan 1/2 turn.

 

 

 

Restart sprayer. If sprayer runs, replace control

 

 

 

board. If sprayer does not run, continue to step 5.

 

 

5. Perform Spin Test: Test at large 4-pin motor field

 

 

 

connector. Disconnect fluid pump from sprayer. Test

 

 

 

motor by placing a jumper across pins 1 & 2. Rotate

 

 

 

motor fan at about 2 revolutions per second. A cogging

 

 

 

resistance to motion should be felt at the fan.

 

 

 

The motor should be replaced if no resistance is felt.

 

 

 

Repeat for pin combinations 1 & 3 and 2 & 3. Pin 4

 

 

 

(the green wire) is not used in this test. If all spin test

 

 

 

is positive, continue to step 6.

 

 

 

Green Blue Red Black

STEP 1:

Green Blue Red Black

STEP 2:

Green Blue Red Black

STEP 3:

311365G

15

Image 15
Contents Important Safety Instructions Korean patent10-0579681Mark Table of Contents Models Vac Model Type Lo-Boy Hi-Boy 240 Grounding Grounding InstructionsSkin Injection Hazard Fire and Explosion HazardMoving Parts Hazard Equipment Misuse HazardElectric Shock Hazard Pressurized Aluminum Parts HazardComponent Identification and Function General Repair Information Pressure Relief ProcedureGrounding Mechanical/Fluid Flow What to Check What to do Type of ProblemTroubleshooting Electrical Type of Problem What to Check HOW to CheckSprayer does not run at all Check transducer or transducer Step 100k ohm Reconnect thermal device connector to control YES Sprayer Will Not Shut OffSee following page for steps Sprayer Will Not RunInstallation Pressure Control BoardRemoval 100 120 Vac North American Japan/Taiwan Vac Motor Control Board 240 Vac Vac Filter BoardVac U.K. Motor Control Board Vac U.K. Filter Board Vac U.K Pressure Adjust Potentiometer Pressure Control Transducer Install control box 61 and control panel 68 with four screws DisassemblyAssembly Drive and Bearing Housing Replacement158 108 Motor Replacement InstallationRemoval 158 90a 612 906 Displacement Pump Replacement for 695/795 Ti7169a Displacement Pump Replacement 1095/1595/Mark Open pump door Tighten latch and rotate latch lock into locked position Wiring Diagram ON/OFF Japan/Taiwan Japan/Taiwan Models For Graco Canada Customers Graco Standard Warranty