Senco PC1010 operating instructions Preparation, Initial SET-UP, Location, Electrical

Page 10

PREPARATION

INITIAL SET-UP:

1.Read safety warnings before setting-up air compressor.

LOCATION:

CAUTION

In order to avoid damaging the air compressor,do not incline the air compressor transversely or longitudinally more than 10 °.

1.Place air compressor at least 12 inches away from obstacles that may prevent proper ventilation. Do not place air compressor in an area:

-where there is evidence of oil or gas leaks.

-where flammable gas vapors or materials may be present.

WARNING

Serious injury or death may occur if electrical sparks from motor and pressure switch come in contact with flammable vapors, combustible dust, gases or other

combustible materials. When using the air compressor for spray painting, place the air compressor as far away from the work area as possible,using extra air hoses instead of extension cords.

-where air temperatures fall below 32 °F or exceed 104 °F.

-where extremely dirty air or water could be drawn into the air compressor.

ELECTRICAL:

DANGER

Improper connection of the equipment-grounding conductor can result in a risk of shock or electrocution. Check with a qualified electrician or service personnel if

you are in doubt as to whether the outlet is properly grounded. Do not use any type of adapter with this product. If repair or replacement of the cord or plug is necessary,do not connect the grounding wire to either flat blade terminal. The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire.

WARNING

This product must be grounded.If there should be a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This product is equipped with a cord having an equipment-

grounding conductor and a grounding type plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

1.Senco ® DOES NOT RECOMMEND THE USE OF EXTENSION CORDS as this can create power loss and overheating of the motor. Use of an additional air hose is recommended rather than an extension cord. If use of an extension cord is unavoidable,it should be plugged into a GFCI found in circuit boxes or protected receptacles. When using an extension cord,observe the following:

Cable Length

Wire Gauge

Up to 25 feet

12 AWG

Up to 100 feet

10 AWG

Up to 150 feet

8 AWG

Up to 250 feet

6 AWG

Use only 3-blade extension cords that have 3-blade grounding-type plugs and 3-slot cord connectors that will accept the plug from the product. Use only extension cords having an electrical rating not less than the rating of the product. Do not use damaged extension cords. Examine extension cord before using and replace if damaged. Do not abuse extension cord and do not yank on any cord to disconnect. Keep cord away from heat and sharp edges. Always shut off the air compressor switch before removing the plug from the receptacle.

10

Image 10
Contents Operating Instructions Table of Contents Introduction Safety AlertInspection Electric Shock Safety WarningsHazard Potential Consequence Prevention Risk ElectrocutionExplosion or Fire BurstingBurns Hazard Potential Consequence Prevention Risk toBreathing FlyingNegligence Hazard Potential Consequence Prevention Risk fromMoving Parts AIR Compressor DamageCompressor Features Compressor Features Location PreparationInitial SET-UP ElectricalMaintenance OperationRemedy TroubleshootingProbable Cause Probable Cause RemedySymptom 5. Air leaks from safety relief valve Symptom 10. Air compressor not making enough air Specifications RPMSenco Compressor and Parts Warranty PC1010 1/2 HP Electric Air Compressor Compresseur d’air électrique PC Table DES Matières Mises EN Garde DE SécuritéAlertes Pour LA Sécurité Commotion Électrique Mises EN Garde DE SécuritéConsequences Potentielles Prevention Risque DE OU D’ÉLECTROCUTIONRisque Conséquences Potentielles Prévention Risque D’EXPLOSIONOU D’INCENDIE ’ÉCLATEMENTRisque DE Brûlure Conséquences Potentielles Prévention Risque’INHALATION ’OBJETSConservez CES Instructions Caractéristiques DU Compresseur Page Mise EN Œuvre Initiale EmplacementPréparation AvertissementDémarrage FonctionnementListe DE Vérifications Préliminaires CoupureCause Probable DépannageRemède Cause Probable Remède Symptôme 11 Humidité dans l’air en sortie Spécifications Garantie Senco Pour LE Compresseur ET LES Pièces PC1010, compresseur d’air électrique 1/2 CV Instruccione de Operación Indice Advertencias¡AVISO DE Seguridad IntroducciónInspección Electrochoque Medidas DE SeguridadRiesgo Consecuencia Potencial Prevención Riesgo DE ElectrocuciónIncendio EstallidoQuemaduras Riesgo Potential Consequence Prevención Riesgo Para LASVias Respiratorias Riesgo DE SER¡GUARDE Estas Instrucciones Características DEL Compresor Page Emplazamiento PreparaciónMontaje Inicial AdvertenciaFuncionamiento Causa Probable Localización Y Solución DE AveríasSolución Causa Probable Solución Síntoma 10. El compresor no produce suficiente aire Especificaciones Nº de modelo MotorGarantia Senco Para EL Compresor Y LAS Piezas Compresor de aire eléctrico 1/2 HP PC1010