ELECTRICALGROUNDINGINSTRUCTIONS: (continued)
DUTY CYCLE:
Toensure long life of your BOSTITCHair compressor,do not operateon more than a 50% duty cycle. If this air compressor pumpsair more than 50% of one hour,then the compressor’s capability is less than the air delivery requiredby the application. Alwaysmatchthe air volume requirements of the attachmentor accessorywith the air volumedeliveryof the compressor.
Notice!: BOSTITCH does not recommend the use of extension cordswith compressors. The use of an extension cord can resultin the loss of voltagesuppliedto the compressorwhich could prevent the compressor from starting. For optimum performance,plug the compressor directly into an outlet and increase the lengthof airlineas needed.
If an extension cord must be used,use theseguidelines:
Distance Needed | RecommendedGauge |
Less than 25 ft. | 12 Gauge |
25 - 50 ft. | 10 Gauge |
Greater than 50 ft. | Not Recommended |
| SPECIFICATIONS |
Motor: | 2HP (Peak)/ 1.5HP(Running) |
| 115V – 60HZ |
Fuse Requirements: | 15 Amps minimum |
OperatingPressure: | 0 – 150PSI |
SafetyValveSetting: | 160 PSI |
Air Delivery: | 3.7 CFM @ 40 PSI |
| 2.8 CFM @ 90 PSI |
MaximumAmps at WorkingPressure: | 12 |
TankSize: | 1.2 Gallons |
Air Outlet: | 1/4" NPT |
PressureSwitchSettings: | On @ 120 PSI |
| Off @ 150 PSI |
Weight: | 22lbs. |
PSI = PoundsPer SquareInch: | CFM = CubicFeet Per Minute |
6