Agilent Technologies 8922 P manual Select ‘Master’ to measure before signalling mobile

Page 43

Screens

HSCSD screen

Limits (GSM900)

1 thru 124

 

 

Limits (E-GSM)

0 thru 124; 995 thru 1024

 

 

Limits (DCS1800)

512 thru 885

 

 

Limits (PCS1900)

512 thru 810

 

 

Default (GSM900)

30

 

 

Default (E-GSM)

30

 

 

Default (DCS1800)

512

 

 

Default (PCS1900)

512

 

 

The Master Channel field shows the ARFCN of the TCH. There is only one ARFCN, as HSCSD systems place all timeslots on the same ARFCN.

On a slave unit, setting this field changes the ARFCN of the downlink

TCH and analyzer appropriately.

On a master unit, this field sets the TCH ARFCN of the current call, or the TCH ARFCN to be used for the next call. An assignment command is sent to the mobile on the downlink FACCH.

If you try to change the ARFCN but the measurement timeslot (see page

32)is set to Slave, an error occurs and the setting is ignored. Without this error, the acknowledgment from the mobile would be missed if the HP/Agilent 8922 is analyzing the slave timeslot. The error reported is

Select ‘Master’ to measure before signalling mobile.

The value of this field is always the same as the TCH ARFCN on the Cell Status screen.

NOTE

The default is reset when the instrument type (see page 24) is selected.

 

 

Chapter 4

29

Image 43
Contents HP/Agilent 8922 GSM Hscsd Test System Option #K09 Warranty Limitation of Remedies and Liability Assistance Statement of Compliance Manufacturer’s Declaration Sound EmissionInstrument dangerous. Intentional interruption is Earthing ground, incorporated in the power cord. The mainsProhibited Safety Symbols Safety SymbolsISM 1-A User’s Guide Abbreviations OverviewContents Remote operation Returning equipment for repair Upgrading the HOP Controller ROM and Firmware Understanding the HP/Agilent HP/Agilent 8922 GSM Hscsd Test System, option #K09 Getting an overview of the HP/Agilent GSM Hscsd Test SystemChapter Features Setting up the HP/Agilent Before you start Checking the HP/Agilent 8922 Requirements for Hscsd Front panel connections Making the front panel connectionsStep Making the rear panel connectionsRear panel connections Inserting the keycard into the HP/Agilent Enabling the Hscsd functionalityTests screen Config screen Calibrating the overall system Manual operation Configuring the system Message Frame reset sent appears in the top left-hand corner Establishing a call Choosing which timeslot to measure Making measurementsMeasuring BER Hscsd control screen Changing power levels, timeslot and channelsEnding a call Ending a call Screens Instrument type Config screenChapter Slave address Master downlink amplitude Hscsd screenMaster channel Slave offsetSelect ‘Master’ to measure before signalling mobile Slave timeslot Master timeslotCall Type Measure Data rateMaster Tx level Master input level Slave Tx level Master modeSlave input level Slave control Mobile reports Peak power displayTo Screen menu Fast BER screen Fast BER ScreenLoopback Remote operation Introduction CONFigureINSTrumentTYPE Configure Subsystem Gpib CommandsConfigure Instrument Type comand syntax Display Screen command syntax Display Subsystem Gpib CommandsDISPlaySCReen Hscsd Hscsd Subsystem Gpib Commands Hscsd command syntax master unit SYNC? TCH Hscsd command syntax slave unitHSCSdMASTerTCHARFCn HSCSdMASTerSTATusTCHTSLot HSCSdMASTerDOWNlinkAMPLitude Command 0ptionsHSCSdMASTerTCHTLEVel HSCSdMASTerUPLinkAMPLitude HSCSdMASTerUPLinkAMPLitudeCONTrol HSCSDMASTerCALLTYPE HSCSDMASTerCALLRATE HSCSdSLAVeSTATusSYNC HSCSdSLAVeSTATusTCHTSLot? HSCSdSLAVeDOWNlinkAMPLitudeOFFSet HSCSdSLAVeTCHTLEVel HSCSdSLAVeUPLinkAMPLitude HSCSdSLAVeUPLinkAMPLitudeCONTrol Configuring the system Remote operating proceduresMaking measurements Establishing a callChanging channels, timeslot and power levels Ending a call Clear Screen Example code showing a dual-band handover from E-GSM to DCSPause Example code showing a dual-band handover from E-GSM to DCS Returning equipment for repair Return Procedure Chapter Sales and Service Offices Canada Sales and Service Offices Upgrading the HOP Controller ROM and Firmware ROM Upgrading the Hop Controller ROMSide View Figure A-4 Removing the A33 U62 HOP Controller ROM Figure A-3 Removing the A33 Hop Controller BoardUpgrading the Hop Controller ROM Upgrading the firmware