NOTE
NOTE
Screens
HSCSD screen
7. Data rate
Type | Toggle |
|
|
Units | None |
|
|
Choices | “9.6” or “14.4” |
|
|
Default | “9.6” |
|
|
The Data rate field determines the data rate associated with the HSCSD 2x2 call. Selecting '9.6' sets up a call at 9.6 kbit/s per timeslot (19.2 kbit/s) and selecting '14.4' sets up a call at 14.4 kbit/s per timeslot
(28.8 kbit/s).
The value of the Data rate field can not be changed while a call is in progress.
8. Measure
Type | Toggle |
|
|
Units | None |
|
|
Choices | “Master” or “Slave” |
|
|
Default (slave unit) | “Slave” |
|
|
Default (other units) | “Master” |
|
|
The Measure field sets which of the uplink TCHs are to be measured or demodulated. The display updates (next to the Mobile reports and Peak Power displays) to show which timeslot is being analyzed.
The Measure field also selects which analyzer level to use, either the Master input level (see page 34) or the Slave input level (see page 36).
The default is reset when you select the instrument type (see page 24).
32 | Chapter 4 |