Agilent Technologies 8922 P manual HSCSdMASTerTCHARFCn

Page 62

 

Remote operation

 

HSCSD Subsystem GPIB Commands

 

HSCSd:MASTer:TCH:ARFCn

Description

Setting this during a call forces a channel assignment to the given

 

channel. Note that existing channel assignment commands sent to a

 

master or single unit have the same effect. In particular, a dual band

 

assignment must be performed using the existing dual band commands.

 

If the measurement timeslot is not set to “Master”, attempting to

 

perform a channel assignment on a master or single unit will produce an

 

error, and the setting will be ignored. The error message is Select

 

Master to measure before signalling mobile. When the system is

 

idle (that is, not on a call) this sets the channel which will be used when

 

the next call is established. This command must also be sent to the slave

 

unit.

Syntax

HSCSd:MASTer:TCH:ARFCn <integer>

 

HSCSd:MASTer:TCH:ARFCn?

Command options

Type

integer

 

 

Units:

none (ARFCN)

 

 

Limits (GSM900):

1 thru 124

 

 

Limits (E-GSM):

0 thru 124; 995 thru 1024

 

 

Limits (DCS1800):

512 thru 885

 

 

Limits (PCS1900):

512 thru 810

 

 

Default (GSM900):

30

 

 

Default (E-GSM):

30

 

 

Default (DCS1800):

512

 

 

Default (PCS1900):

51

 

 

48

Chapter 5

Image 62
Contents HP/Agilent 8922 GSM Hscsd Test System Option #K09 Warranty Limitation of Remedies and Liability Assistance Statement of Compliance Sound Emission Manufacturer’s DeclarationProhibited Earthing ground, incorporated in the power cord. The mainsInstrument dangerous. Intentional interruption is Safety Symbols Safety SymbolsISM 1-A Overview User’s Guide AbbreviationsContents Remote operation Returning equipment for repair Upgrading the HOP Controller ROM and Firmware Understanding the HP/Agilent Getting an overview of the HP/Agilent GSM Hscsd Test System HP/Agilent 8922 GSM Hscsd Test System, option #K09Chapter Features Setting up the HP/Agilent Before you start Checking the HP/Agilent 8922 Requirements for Hscsd Making the front panel connections Front panel connectionsMaking the rear panel connections StepRear panel connections Enabling the Hscsd functionality Inserting the keycard into the HP/AgilentTests screen Config screen Calibrating the overall system Manual operation Configuring the system Message Frame reset sent appears in the top left-hand corner Establishing a call Measuring BER Making measurementsChoosing which timeslot to measure Changing power levels, timeslot and channels Hscsd control screenEnding a call Ending a call Screens Config screen Instrument typeChapter Slave address Hscsd screen Master downlink amplitudeSlave offset Master channelSelect ‘Master’ to measure before signalling mobile Master timeslot Slave timeslotCall Type Data rate MeasureMaster Tx level Master input level Master mode Slave Tx levelSlave input level Slave control To Screen menu Peak power displayMobile reports Fast BER Screen Fast BER screenLoopback Remote operation Introduction Configure Instrument Type comand syntax Configure Subsystem Gpib CommandsCONFigureINSTrumentTYPE DISPlaySCReen Hscsd Display Subsystem Gpib CommandsDisplay Screen command syntax Hscsd Subsystem Gpib Commands Hscsd command syntax master unit Hscsd command syntax slave unit SYNC? TCHHSCSdMASTerTCHARFCn HSCSdMASTerSTATusTCHTSLot Command 0ptions HSCSdMASTerDOWNlinkAMPLitudeHSCSdMASTerTCHTLEVel HSCSdMASTerUPLinkAMPLitude HSCSdMASTerUPLinkAMPLitudeCONTrol HSCSDMASTerCALLTYPE HSCSDMASTerCALLRATE HSCSdSLAVeSTATusSYNC HSCSdSLAVeSTATusTCHTSLot? HSCSdSLAVeDOWNlinkAMPLitudeOFFSet HSCSdSLAVeTCHTLEVel HSCSdSLAVeUPLinkAMPLitude HSCSdSLAVeUPLinkAMPLitudeCONTrol Remote operating procedures Configuring the systemEstablishing a call Making measurementsChanging channels, timeslot and power levels Ending a call Example code showing a dual-band handover from E-GSM to DCS Clear ScreenPause Example code showing a dual-band handover from E-GSM to DCS Returning equipment for repair Return Procedure Chapter Sales and Service Offices Canada Sales and Service Offices Upgrading the HOP Controller ROM and Firmware Upgrading the Hop Controller ROM ROMSide View Figure A-3 Removing the A33 Hop Controller Board Figure A-4 Removing the A33 U62 HOP Controller ROMUpgrading the Hop Controller ROM Upgrading the firmware