Agilent Technologies 8922 P manual Call Type

Page 45

Screens

HSCSD screen

6. Call Type

Type

Units

Default

Values

Toggle

None

2x2

2x2 or 2x1

 

The Call Type field determines which type of HSCSD call the HP/

 

Agilent 8922 establishes the next time a call is initiated.

 

If you select 2x1, the HP/Agilent 8922 tries to establish a call with 2

 

downlinks and 1 uplink when a call is next initiated. The measure

 

timeslot field will no longer be visible, nor will the controls concerned

 

with the second uplink (Slave TX level, Slave input level, Slave

 

input level control mode).

 

If you select 2x2, the HP/Agilent 8922 sets up a call with 2 downlinks

 

and 2 uplinks. The Measure timeslot field appears, along with controls

 

associated with the second uplink. The Measure timeslot field is set to

 

the default for each unit (slave for slave, master for master).

 

Each of these changes is subject to the conditions that a call must not be

NOTE

 

in progress when the change to this field is made and that the field will

 

not change if changing the slave timeslot would make it take on an

 

illegal value.

 

 

Chapter 4

31

Image 45
Contents HP/Agilent 8922 GSM Hscsd Test System Option #K09 Warranty Limitation of Remedies and Liability Assistance Statement of Compliance Manufacturer’s Declaration Sound EmissionEarthing ground, incorporated in the power cord. The mains Instrument dangerous. Intentional interruption isProhibited Safety Symbols Safety SymbolsISM 1-A User’s Guide Abbreviations OverviewContents Remote operation Returning equipment for repair Upgrading the HOP Controller ROM and Firmware Understanding the HP/Agilent HP/Agilent 8922 GSM Hscsd Test System, option #K09 Getting an overview of the HP/Agilent GSM Hscsd Test SystemChapter Features Setting up the HP/Agilent Before you start Checking the HP/Agilent 8922 Requirements for Hscsd Front panel connections Making the front panel connectionsStep Making the rear panel connectionsRear panel connections Inserting the keycard into the HP/Agilent Enabling the Hscsd functionalityTests screen Config screen Calibrating the overall system Manual operation Configuring the system Message Frame reset sent appears in the top left-hand corner Establishing a call Making measurements Choosing which timeslot to measureMeasuring BER Hscsd control screen Changing power levels, timeslot and channelsEnding a call Ending a call Screens Instrument type Config screenChapter Slave address Master downlink amplitude Hscsd screenMaster channel Slave offsetSelect ‘Master’ to measure before signalling mobile Slave timeslot Master timeslotCall Type Measure Data rateMaster Tx level Master input level Slave Tx level Master modeSlave input level Slave control Peak power display Mobile reportsTo Screen menu Fast BER screen Fast BER ScreenLoopback Remote operation Introduction Configure Subsystem Gpib Commands CONFigureINSTrumentTYPEConfigure Instrument Type comand syntax Display Subsystem Gpib Commands Display Screen command syntaxDISPlaySCReen Hscsd Hscsd Subsystem Gpib Commands Hscsd command syntax master unit SYNC? TCH Hscsd command syntax slave unitHSCSdMASTerTCHARFCn HSCSdMASTerSTATusTCHTSLot HSCSdMASTerDOWNlinkAMPLitude Command 0ptionsHSCSdMASTerTCHTLEVel HSCSdMASTerUPLinkAMPLitude HSCSdMASTerUPLinkAMPLitudeCONTrol HSCSDMASTerCALLTYPE HSCSDMASTerCALLRATE HSCSdSLAVeSTATusSYNC HSCSdSLAVeSTATusTCHTSLot? HSCSdSLAVeDOWNlinkAMPLitudeOFFSet HSCSdSLAVeTCHTLEVel HSCSdSLAVeUPLinkAMPLitude HSCSdSLAVeUPLinkAMPLitudeCONTrol Configuring the system Remote operating proceduresMaking measurements Establishing a callChanging channels, timeslot and power levels Ending a call Clear Screen Example code showing a dual-band handover from E-GSM to DCSPause Example code showing a dual-band handover from E-GSM to DCS Returning equipment for repair Return Procedure Chapter Sales and Service Offices Canada Sales and Service Offices Upgrading the HOP Controller ROM and Firmware ROM Upgrading the Hop Controller ROMSide View Figure A-4 Removing the A33 U62 HOP Controller ROM Figure A-3 Removing the A33 Hop Controller BoardUpgrading the Hop Controller ROM Upgrading the firmware