| Remote operation |
| HSCSD Subsystem GPIB Commands |
| HSCSd:MASTer:UPLink:AMPLitude:CONTrol |
Description | This defines the relationship between the master’s Tx level, and the |
| master’s expected uplink amplitude. MS TX LEV indicates that setting |
| the master’s Tx level also sets the master’s expected uplink amplitude. |
| MANUAL indicates that setting the master’s expected uplink amplitude is |
| independent from the value of the master’s Tx level. |
| Note that in standard mode, setting either the master’s Tx level, or the |
| master’s expected uplink amplitude, forces the value of the master’s |
| amplitude control to MS TX LEV or MANUAL respectively. |
Syntax | HSCSd:MASTer:UPLink:AMPLitude:CONTrol? |
| HSCSd:MASTer:UPLink:AMPLitude:CONTrol <string> |
Command options | ‘MS TX LEV’ ‘MANUAL’ |
Chapter 5 | 53 |